Skip to main content
QUICK REVIEW

[Paper Review] Synth-by-Reg (SbR): Contrastive learning for synthesis-based registration of paired images

Adrià Casamitjana, Matteo Mancini|arXiv (Cornell University)|Jul 30, 2021
AI in cancer detectionComputer Science42 references23 citations
TL;DR

This paper proposes Synth-by-Reg (SbR), a novel unsupervised framework for inter-modality image registration that inverts the traditional synthesis-by-registration approach by using a frozen registration network to guide image synthesis. It introduces a registration loss based on ℓ1 similarity and a contrastive learning-based geometric consistency loss to prevent blurring and artifacts, achieving 13% lower landmark error than mutual information-based methods and 11% lower than CycleGAN on histology-to-MRI registration, with performance comparable to supervised methods.

ABSTRACT

Nonlinear inter-modality registration is often challenging due to the lack of objective functions that are good proxies for alignment. Here we propose a synthesis-by-registration method to convert this problem into an easier intra-modality task. We introduce a registration loss for weakly supervised image translation between domains that does not require perfectly aligned training data. This loss capitalises on a registration U-Net with frozen weights, to drive a synthesis CNN towards the desired translation. We complement this loss with a structure preserving constraint based on contrastive learning, which prevents blurring and content shifts due to overfitting. We apply this method to the registration of histological sections to MRI slices, a key step in 3D histology reconstruction. Results on two different public datasets show improvements over registration based on mutual information (13% reduction in landmark error) and synthesis-based algorithms such as CycleGAN (11% reduction), and are comparable to a registration CNN with label supervision. Code and data are publicly available at \url{https://github.com/acasamitjana/SynthByReg}

Motivation & Objective

  • To address the challenge of nonlinear inter-modality registration, especially in histology-to-MRI alignment, where traditional similarity metrics like mutual information perform poorly.
  • To overcome limitations of GAN-based synthesis methods, such as hallucinations, blurring, and artifacts due to overfitting.
  • To develop a weakly supervised, unsupervised framework that does not require perfectly aligned training data or complex adversarial training.
  • To improve registration accuracy by leveraging a frozen registration network as a differentiable supervisory signal for image synthesis.
  • To ensure geometric fidelity in synthesized images using contrastive learning at the patch level, preventing content shifts and structural degradation.

Proposed method

  • The method uses a frozen U-Net-based registration network R(θR) trained on target-domain (e.g., MRI) image pairs to predict deformation fields, which are used to supervise image synthesis.
  • A synthesis CNN G(θG) translates source images (e.g., histology) to the target modality (e.g., MRI) using a novel registration loss Lreg that measures ℓ1 similarity between the target image T and the deformed synthesized image ST(Φ).
  • A contrastive geometric consistency loss Lgeo is introduced using PatchNCE to enforce that local image patches in the source and synthesized images are semantically aligned, preventing blurring and content shifts.
  • The total loss is L(θG) = Lreg + λgeo·Lgeo, with λgeo = 0.02, trained end-to-end with backpropagation through the frozen registration network.
  • The framework avoids cycle-consistency or distribution-matching losses (e.g., CycleGAN), reducing training instability and memory usage.
  • The method outputs both the synthesized image and the deformation field, enabling direct use in downstream registration tasks.

Experimental results

Research questions

  • RQ1Can a frozen registration network be used as a supervisory signal to train an image synthesis network for inter-modality registration?
  • RQ2Does incorporating a contrastive learning-based geometric consistency loss improve structural fidelity in synthesized images compared to standard GAN-based methods?
  • RQ3Can a synthesis-by-registration approach outperform traditional inter-modality registration metrics like mutual information in nonlinear, non-rigid settings?
  • RQ4To what extent does the proposed method reduce artifacts such as blurring and contrast flipping in histology-to-MRI translation?
  • RQ5Does the method achieve performance comparable to supervised registration without requiring ground-truth deformation fields or segmentation labels?

Key findings

  • SbR achieved a 13% reduction in landmark error compared to mutual information-based registration on the Allen Human Brain Atlas dataset, with a p-value < 0.001.
  • On the BigBrain dataset, SbR reduced landmark error by 23% compared to cGAN and 33% compared to RoT, both statistically significant (p < 0.001).
  • The ablated version without the geometric consistency loss (SbR-N) showed degraded performance due to synthetic artifacts, demonstrating the necessity of the contrastive loss.
  • SbR achieved Dice scores on tissue classes comparable to NMIw, despite not using segmentation labels during training, indicating robust structural alignment.
  • Extensions with additional losses (SbR-G and SbR-R) did not yield statistically significant improvements, suggesting the core SbR loss is already optimal.
  • Qualitative results show robust registration of complex structures like the cortex, even in the presence of staining artifacts and intensity inhomogeneities.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.