[Paper Review] Synthesis of Positron Emission Tomography (PET) Images via Multi-channel Generative Adversarial Networks (GANs)

Lei Bi, Jinman Kim|arXiv (Cornell University)|Jul 31, 2017
Generative Adversarial Networks and Image SynthesisComputer Science18 references24 citations
TL;DR

This paper proposes a multi-channel generative adversarial network (M-GAN) that synthesizes realistic PET images by jointly leveraging tumor annotations and CT anatomical information to guide lesion generation and spatial consistency. The method produces high-fidelity synthetic PET scans that, when used to train a tumor detection model, achieve 52.38% recall—only 2.79% lower than with real data—demonstrating strong potential for enhancing training data in PET-based machine learning.

ABSTRACT

Positron emission tomography (PET) image synthesis plays an important role, which can be used to boost the training data for computer aided diagnosis systems. However, existing image synthesis methods have problems in synthesizing the low resolution PET images. To address these limitations, we propose multi-channel generative adversarial networks (M-GAN) based PET image synthesis method. Different to the existing methods which rely on using low-level features, the proposed M-GAN is capable to represent the features in a high-level of semantic based on the adversarial learning concept. In addition, M-GAN enables to take the input from the annotation (label) to synthesize the high uptake regions e.g., tumors and from the computed tomography (CT) images to constrain the appearance consistency and output the synthetic PET images directly. Our results on 50 lung cancer PET-CT studies indicate that our method was much closer to the real PET images when compared with the existing methods.

Motivation & Objective

  • Address the scarcity of annotated PET imaging data for training machine learning models in oncology.
  • Overcome limitations of existing synthetic PET methods, such as poor anatomical fidelity and inability to generate accurate tumor regions.
  • Develop a unified deep learning framework that integrates tumor annotations and CT images to synthesize anatomically consistent, high-uptake PET images.
  • Evaluate whether synthetic PET data can effectively augment real data for training robust tumor detection models in lung cancer.

Proposed method

  • Employ a multi-channel GAN architecture that takes both CT images and tumor segmentation labels as input to generate synthetic PET images.
  • Use adversarial training between a generator and a discriminator to learn high-level semantic representations and improve image realism.
  • Integrate label information to guide the generation of high-uptake regions (e.g., tumors) and CT data to enforce anatomical consistency and spatial structure.
  • Train the generator to minimize perceptual and reconstruction losses, including mean absolute error (MAE) and peak signal-to-noise ratio (PSNR), to ensure image quality.
  • Apply the GAN to 50 lung cancer PET-CT scans to generate synthetic data, which are then used to train a fully convolutional network (FCN) for tumor detection.
  • Use cross-validation by splitting data into training and testing groups, with synthetic data from one group used to train the FCN and tested on real images from the other.

Experimental results

Research questions

  • RQ1Can a multi-channel GAN effectively synthesize realistic PET images that preserve anatomical structure and tumor-specific uptake patterns?
  • RQ2How does the inclusion of both CT and tumor label inputs improve the realism and consistency of synthetic PET images compared to single-input GANs?
  • RQ3To what extent can synthetic PET images trained with M-GAN improve the performance of a tumor detection model compared to real data?
  • RQ4How does the M-GAN-based synthetic data compare to other GAN variants (e.g., LB-GAN, CT-GAN) in terms of image quality and downstream task performance?

Key findings

  • The M-GAN achieved the lowest mean absolute error (MAE) of 4.60 and highest peak signal-to-noise ratio (PSNR) of 28.06 among all GAN variants, indicating superior image quality.
  • Synthetic PET images generated by M-GAN showed significantly better anatomical fidelity and tumor localization compared to LB-GAN and CT-GAN, which suffered from misaligned structures and missing lesions.
  • The FCN model trained on M-GAN synthetic data achieved a recall of 52.38%, which was only 2.79% lower than the recall (55.17%) of the model trained on real PET data.
  • The M-GAN outperformed both LB-GAN (44.06% recall) and CT-GAN (3.69% recall) in tumor detection, demonstrating the effectiveness of joint label and CT guidance.
  • The M-GAN framework successfully generated tumors in correct anatomical locations, including challenging regions like the mediastinum, where CT-GAN failed.
  • The results suggest that M-GAN-generated synthetic data can effectively augment real data, enhancing training for PET-based computer-aided diagnosis systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.