TL;DR

This technical design report details the PANDA Endcap Disc DIRC, a particle identification detector for the PANDA experiment at FAIR, using refractive and focusing optics to detect Cherenkov photons from charged particles. The system employs MCP-PMTs, custom ROMs, and a nitrogen gas purge to maintain low humidity, achieving high pion-kaon separation performance in a mechanically robust, maintenance-free design optimized for high-rate operation in a high-magnetic-field environment.

ABSTRACT

PANDA (anti-proton annihiliation at Darmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2 × 10$^{32}$ cm$^{−2}$ s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA disc DIRC detector that has not been used in any other high energy physics experiment before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees sufficient safety margins.

Motivation & Objective

  • To design a high-performance, maintenance-free particle identification system for the PANDA experiment at FAIR.
  • To achieve precise pion-kaon separation using a disc-shaped DIRC with refractive and focusing optics.
  • To ensure long-term stability and radiation hardness in a high-magnetic-field environment.
  • To integrate the detector into the PANDA endcap with minimal impact on detector access and cooling.
  • To implement a dry nitrogen gas system to protect sensitive optical components from humidity and outgassing.

Proposed method

  • The DIRC uses fused silica radiator discs and focusing optics to guide Cherenkov photons to MCP-PMTs.
  • Each quadrant is assembled as a rigid, alignment-stable unit with integrated ROM (Readout Module) housings.
  • A dry nitrogen gas system flows through 3 mm tubes along the stabilizing cross to maintain low humidity around optics.
  • HV and LV cables, data fibers, and cooling lines are routed through a structured cable tray with 200 mm z-space clearance.
  • Front-end electronics (FEE) are placed outside the ROM housing to reduce outgassing and thermal load.
  • The system is designed for modular replacement of MCP-PMTs and ROMs during long shutdowns.

Experimental results

Research questions

  • RQ1How can a high-precision, maintenance-free DIRC be designed for operation in the high-magnetic-field environment of the PANDA experiment?
  • RQ2What is the optimal mechanical and gas-purging configuration to protect sensitive fused silica optics from humidity and outgassing?
  • RQ3How can the integration of high-voltage, data, and cooling cables be achieved without compromising mechanical stability or access?
  • RQ4What is the required gas flow rate and distribution to maintain a low-moisture environment across all optical components?
  • RQ5How can the system be designed to allow for future replacement of key components like MCP-PMTs without full detector disassembly?

Key findings

  • The PANDA Endcap Disc DIRC is designed as a rigid, alignment-stable unit with 96 MCP-PMTs and 96 ROMs per quadrant.
  • A dry nitrogen gas system with flow rates of several liters per hour per quadrant maintains a low-moisture environment around the optics.
  • The system includes 10,100 mm² of total cable cross-section, with dedicated routing for HV, LV, data, gas, cooling, and laser lines.
  • The FEE is placed outside the ROM housing to minimize outgassing and thermal load on the optical components.
  • The design allows for modular replacement of MCP-PMTs and ROMs, though full EDD removal is required for MCP-PMT replacement.
  • The system is engineered for maintenance-free operation under high-rate, high-magnetic-field conditions, with no significant degradation expected from a single faulty MCP-PMT.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.