[Paper Review] Terahertz non-label subwavelength imaging with composite photonics-plasmonics structured illumination
This paper proposes a terahertz non-label subwavelength imaging method using composite photonics-plasmonics structured illumination, leveraging spoof surface plasmons (SSPs) on a metal grating to down-modulate high-order spatial frequency components into detectable low-order ones. By combining SSPs illumination with vertical and oblique traveling wave excitation, and applying an iterative post-processing algorithm, the method achieves a resolution of up to 0.12λ₀, surpassing the classical diffraction limit and enabling label-free, weak-scattering sample imaging.
Inspired by the capability of structured illumination microscopy in subwavelength imaging, many researchers devoted themselves to investigating this methodology. However, due to the free propagating feature of the traditional structured illumination fields, the resolution can be only improved up to double times compared with the diffractied limited microscopy. Besides, most of the previous studies, relying on incoherent illumination sources, are restricted to fluorescent samples. In this work, a subwavelength nonfluorescent imaging method is proposed based on the terahertz traveling wave and plasmonics illumination. Excited along with a metal grating, the spoof surface plasmons are employed as the plasmonics illumination. When the scattering waves with the SSPs illumination are captured, the high order spatial frequency components of the sample are already encoded into the obtainable low order ones. Then, an algorithm is summarized to shift the modulated SF components to their actual positions in the Fourier domain. In this manner, high order SF components carrying the fine information are introduced to reconstruct the desired imaging, leading to an improvement of the resolution up to 0.12 lambda. Encouragingly, the resolution can be further enhanced by tuning the working frequency of the SSPs. This method holds promise for some important applications in terahertz nonfluorescent microscopy and sample detection with weak scattering.
Motivation & Objective
- To overcome the diffraction limit in terahertz microscopy for non-fluorescent, label-free samples.
- To address the resolution limitation of conventional structured illumination microscopy (SIM), which is restricted to a two-fold improvement.
- To enable subwavelength imaging in the terahertz band using coherent, plasmonic, and photonic structured illumination.
- To develop a post-processing algorithm that reconstructs high-order spatial frequency components from modulated, detectable low-order components.
- To demonstrate the method’s robustness across varying sample permittivity and geometry.
Proposed method
- The method employs spoof surface plasmons (SSPs) excited on a metal grating as plasmonic illumination to encode high-order spatial frequency (SF) components of a sample into detectable low-order SF components.
- Vertical and oblique incident traveling waves (photonics illumination) are used to capture additional low-order SF information, complementing the SSPs' contribution.
- The scattering field from the sample is measured under nine distinct illumination patterns, each corresponding to a different spatial frequency modulation.
- An iterative post-processing algorithm is applied to shift the modulated SF components to their true positions in the Fourier domain, reconstructing a wideband SF spectrum.
- The coherent point spread function (PSF) is modeled as a rectangular low-pass filter with a cutoff at k₀, simulating the system’s detection bandwidth.
- The method combines plasmonic and photonic illumination to extend the effective numerical aperture and enhance resolution beyond the diffraction limit.
Experimental results
Research questions
- RQ1Can spoof surface plasmons (SSPs) be used to achieve subwavelength resolution in terahertz imaging of non-fluorescent samples?
- RQ2How does the combination of SSPs and traveling wave illumination improve the effective spatial frequency bandwidth beyond conventional SIM?
- RQ3To what extent can the resolution be enhanced by tuning the SSPs’ working frequency?
- RQ4Can the proposed method distinguish samples with different relative permittivities based on scattering intensity?
- RQ5How robust is the imaging reconstruction algorithm under variations in sample geometry and dielectric properties?
Key findings
- The proposed method achieves a subwavelength resolution of 0.12λ₀, verified against both Abbe’s and Rayleigh’s diffraction criteria.
- The resolution can be further enhanced by tuning the working frequency of the spoof surface plasmons (SSPs), indicating tunable performance.
- The method successfully reconstructs two identical samples with a 0.225λ₀ gap, demonstrating subwavelength resolution capability.
- The imaging system can distinguish samples with different relative permittivities, such as ε = 2.5 and ε = 4.5, based on scattering intensity differences.
- Three samples with gaps of 0.25λ₀ and 0.45λ₀ are successfully reconstructed, confirming the method’s capability for multi-object imaging.
- The method is robust across varying sample parameters, including height, width, and permittivity, as validated through simulations.
Read this paper