Skip to main content
QUICK REVIEW

[Paper Review] The ARIEL Instrument Control Unit design for the M4 Mission Selection Review of the ESA's Cosmic Vision Program

Mauro Focardi, E. Pace|UCL Discovery (University College London)|May 27, 2017
Calibration and Measurement TechniquesEngineering7 references9 citations
TL;DR

This paper presents the design of the ARIEL Instrument Control Unit (ICU) for the European Space Agency's M4 mission, detailing its role in managing the IR Spectrometer (AIRS) through data pre-processing, commanding, and control. The ICU enables low-latency, high-reliability operations using heritage components like Teledyne MCT detectors and SIDECAR ASICs, achieving >98% system reliability and supporting on-board lossless compression and autonomous mode execution.

ABSTRACT

The Atmospheric Remote-sensing Infrared Exoplanet Large-survey mission (ARIEL) is one of the three present candidates for the ESA M4 (the fourth medium mission) launch opportunity. The proposed Payload will perform a large unbiased spectroscopic survey from space concerning the nature of exoplanets atmospheres and their interiors to determine the key factors affecting the formation and evolution of planetary systems. ARIEL will observe a large number (>500) of warm and hot transiting gas giants, Neptunes and super-Earths around a wide range of host star types, targeting planets hotter than 600 K to take advantage of their well-mixed atmospheres. It will exploit primary and secondary transits spectroscopy in the 1.2-8 um spectral range and broad-band photometry in the optical and Near IR (NIR). The main instrument of the ARIEL Payload is the IR Spectrometer (AIRS) providing low-resolution spectroscopy in two IR channels: Channel 0 (CH0) for the 1.95-3.90 um band and Channel 1 (CH1) for the 3.90-7.80 um range. It is located at the intermediate focal plane of the telescope and common optical system and it hosts two IR sensors and two cold front-end electronics (CFEE) for detectors readout, a well defined process calibrated for the selected target brightness and driven by the Payload's Instrument Control Unit (ICU).

Motivation & Objective

  • To develop a reliable, low-mass, and low-power Instrument Control Unit (ICU) for the ARIEL space mission’s infrared spectrometer.
  • To enable on-board pre-processing of scientific data from the AIRS spectrometer to reduce downlink volume and support mission objectives.
  • To ensure compatibility with both U.S.- and European-developed detectors through a flexible DCU interface design.
  • To minimize on-board processing complexity to allow maximum flexibility for on-ground data reduction and signal-to-noise optimization.
  • To meet ESA’s mass, power, and volume constraints while ensuring high system reliability (>98%) through heritage components and rigorous testing.

Proposed method

  • The ICU is implemented as a warm electronics unit located in the spacecraft service module, interfacing with cryogenic front-end electronics (CFEE) via a warm FEE (Detector Control Unit, DCU).
  • Three on-board data acquisition modes are implemented: multiple CDS, multiple slopes up-the-ramp, and single slope up-the-ramp sampling, tailored to detector dynamic range and photon flux.
  • The ICU uses a dual-core processor (MPC8313) running C-based software with potential assembly optimization for time-critical tasks, including an interrupt-driven command sequencer inspired by Herschel’s HIFI/SPIRE instruments.
  • On-board data processing includes deglitching and optional lossless compression (e.g., RICE algorithm), with output formatted into CCSDS packets for transmission to the spacecraft’s solid-state memory.
  • The design leverages high-TRL components: Teledyne MCT 512×512 detectors and SIDECAR ASICs, with a DCU based on Euclid mission heritage for robust interface and signal conditioning.
  • Two architectural options are evaluated: a baseline (US detector-focused) and an alternative (EU detector-focused), both maintaining consistent external interfaces to the ICU.

Experimental results

Research questions

  • RQ1How can the ICU be designed to support both U.S.- and European-developed detectors with minimal interface changes?
  • RQ2What on-board processing strategies minimize data volume while preserving scientific fidelity for post-mission ground analysis?
  • RQ3How can system reliability exceed 98% using flight-proven, high-technology-readiness-level components?
  • RQ4What is the optimal balance between on-board processing complexity and on-ground processing flexibility for exoplanet atmosphere spectroscopy?
  • RQ5How do different data acquisition modes (CDS, up-the-ramp) affect signal-to-noise ratio and data handling in the ICU?

Key findings

  • The ICU baseline architecture achieves a system reliability of over 98% due to the use of high-TRL components, including Teledyne MCT detectors and SIDECAR ASICs.
  • The ICU supports three distinct data acquisition modes—multiple CDS, multiple slopes up-the-ramp, and single slope up-the-ramp—optimized for varying photon flux and detector response.
  • The use of a DCU as a warm FEE interface enables consistent external interfaces regardless of detector origin, ensuring design flexibility for both U.S. and European detector paths.
  • On-board lossless compression (e.g., RICE) is feasible and can be evaluated via trade-off studies on the on-board CPU, with performance dependent on deglitching effectiveness.
  • The baseline ICU design is compliant with ESA’s allocated mass, power, and volume margins, including design margins, and is based on flight-proven subsystems.
  • The alternative ICU architecture ensures full system responsibility for the AIRS team, enabling end-to-end verification of the data acquisition chain and optimal performance adaptation to detector-specific needs.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint