This paper proposes a novel denoising method for remote photoplethysmography by leveraging inverse attention masks to estimate noise from regions ignored by the attention mechanism. By using pixel intensity variations in these 'distraction' regions to refine physiological signal estimates, the approach achieves state-of-the-art performance, improving signal-to-noise ratio by up to 5.8 dB and reducing heart rate and breathing rate error by up to 30%.
Attention is a powerful concept in computer vision. End-to-end networks that learn to focus selectively on regions of an image or video often perform strongly. However, other image regions, while not necessarily containing the signal of interest, may contain useful context. We present an approach that exploits the idea that statistics of noise may be shared between the regions that contain the signal of interest and those that do not. Our technique uses the inverse of an attention mask to generate a noise estimate that is then used to denoise temporal observations. We apply this to the task of camera-based physiological measurement. A convolutional attention network is used to learn which regions of a video contain the physiological signal and generate a preliminary estimate. A noise estimate is obtained by using the pixel intensities in the inverse regions of the learned attention mask, this in turn is used to refine the estimate of the physiological signal. We perform experiments on two large benchmark datasets and show that this approach produces state-of-the-art results, increasing the signal-to-noise ratio by up to 5.8 dB, reducing heart rate and breathing rate estimation error by as much as 30%, recovering subtle pulse waveform dynamics, and generalizing from RGB to NIR videos without retraining.
Motivation & Objective
- Address the challenge of noise in remote camera-based physiological signal measurement, which limits accuracy and clinical utility.
- Investigate whether regions ignored by attention mechanisms—typically considered distractions—contain useful noise statistics for improving signal estimation.
- Develop a method that uses inverse attention masks to generate noise estimates without prior assumptions about noise characteristics.
- Improve the fidelity of recovered physiological waveforms, including subtle dynamics like the dicrotic notch, for better downstream clinical metrics.
- Demonstrate generalization to new modalities, such as near-infrared (NIR) video, without retraining.
Proposed method
- Train a convolutional attention network to identify regions in a video containing the physiological signal (e.g., facial regions with pulsatile blood volume changes).
- Generate an inverse attention mask by subtracting the attention mask values from 1, creating a spatial map of regions not used for signal estimation.
- Extract noise estimates from pixel intensity variations in the inverse mask regions, assuming these regions contain noise correlated with the signal regions.
- Use the estimated noise to train a denoising head that refines the initial physiological signal prediction, improving signal-to-noise ratio.
- Apply the method end-to-end on video frames, enabling joint learning of attention and denoising without architectural modifications.
- Evaluate robustness by comparing continuous vs. thresholded inverse masks and analyzing contributions from different spatial regions (e.g., face center vs. frame edges).
Experimental results
Research questions
- RQ1Can regions ignored by an attention mechanism contain useful statistical information about the noise corrupting the physiological signal of interest?
- RQ2Does leveraging inverse attention masks to estimate noise lead to measurable improvements in remote photoplethysmography accuracy?
- RQ3To what extent does the proposed method generalize across datasets and imaging modalities, such as RGB to NIR video, without retraining?
- RQ4How do different spatial regions (e.g., near face vs. background) contribute to noise estimation under varying motion conditions?
- RQ5Can the method recover clinically relevant waveform features, such as the dicrotic notch, that are often lost in existing approaches?
Key findings
- The method achieves a maximum signal-to-noise ratio improvement of 5.8 dB over baseline methods on benchmark datasets.
- Heart rate estimation error is reduced by up to 30% compared to state-of-the-art methods, with a mean absolute error (MAE) of 2.10 BPM using continuous inverse masks.
- Breathing rate MAE is reduced by up to 40% on videos with high head motion (30 deg/sec), dropping from 4.85 BPM to 2.88 BPM.
- The model generalizes effectively to near-infrared (NIR) videos without retraining, reducing HR MAE from 7.78 BPM to 2.34 BPM on the MR-NIRP dataset.
- The method recovers subtle physiological waveform features such as the dicrotic notch and diastolic peak, which are typically undetectable with standard remote sensing techniques.
- Performance is particularly enhanced on videos with glasses, where the method reduces HR MAE to 2.17 BPM compared to 3.33 BPM for the CAN baseline.