Skip to main content
QUICK REVIEW

[Paper Review] The COHERENT Experiment at the Spallation Neutron Source

COHERENT Collaboration, D. Akimov|arXiv (Cornell University)|Sep 29, 2015
Dark Matter and Cosmic PhenomenaPhysics and Astronomy26 citations
TL;DR

The COHERENT experiment at the Spallation Neutron Source (SNS) measures coherent electroweak neutrino-nucleus scattering (CEvNS) using three detector systems—CsI, germanium, and xenon—targeting a 5σ observation within months. It confirms the N² dependence of the cross section and measures neutrino-nucleus interactions with high precision, leveraging the SNS's high-intensity stopped-pion neutrino beam.

ABSTRACT

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

Motivation & Objective

  • To measure coherent electroweak neutrino-nucleus scattering (CEvNS) with high statistical significance using a stopped-pion neutrino beam at the SNS.
  • To verify the N² dependence of the CEvNS cross section, a key prediction of the Standard Model.
  • To measure neutrino-nucleus cross sections on lead, iron, and copper to better model and subtract non-elastic neutrino interactions (NIN) in CEvNS signals.
  • To demonstrate the feasibility of low-threshold, high-sensitivity neutrino detection in cryogenic and scintillating detectors.
  • To establish a foundation for future upgrades with larger target masses and new materials like NaI and argon.

Proposed method

  • Utilizes the high-intensity, low-energy neutrino beam from stopped pions at the SNS, providing a well-characterized source of electron neutrinos.
  • Employs three independent detector systems: CsI(Tl) scintillators, high-purity germanium detectors, and a two-phase xenon time projection chamber.
  • Applies quenching factors and detector efficiency simulations to correct for threshold effects and energy deposition non-linearity in scintillators.
  • Uses active and passive shielding to suppress background, with background levels estimated to be an order of magnitude lower than the CEvNS signal.
  • Performs statistical analysis with systematic uncertainties dominated by the 18.9% uncertainty in the quenching factor at threshold.
  • Employs a 10% uncertainty in the neutrino flux and 10% uncertainty in the Pb(νₑ, n) production rate as key systematic inputs.

Experimental results

Research questions

  • RQ1Can CEvNS be observed with a 5σ significance using the SNS neutrino beam and multiple detector technologies?
  • RQ2Does the measured CEvNS cross section scale with the square of the atomic mass number (N²), as predicted by the Standard Model?
  • RQ3To what extent do non-elastic neutrino interactions (NIN) on lead, iron, and copper contribute to the detector signal, and can they be accurately modeled?
  • RQ4What is the impact of detector threshold and quenching factor uncertainties on the sensitivity and interpretation of CEvNS measurements?
  • RQ5How do the different detector technologies (CsI, Ge, Xe) compare in sensitivity and background rejection for low-energy neutrino detection?

Key findings

  • A 5σ observation of CEvNS is expected within a few months of data taking, due to the high neutrino flux and low background levels at SNS.
  • The dominant systematic uncertainty in the CEvNS rate is 13%, primarily due to the 18.9% uncertainty in the quenching factor at threshold.
  • Background levels are estimated to be an order of magnitude lower than the CEvNS signal, enabling high-significance measurements.
  • The CsI detector is already installed and operational, with data taking expected to continue for approximately three years to reach full sensitivity.
  • The germanium detector system is in advanced development, with final construction and installation expected in the second year of the project, requiring two years of data taking.
  • The xenon detector is expected to be commissioned by the end of FY17, with one year of purification required before installation, and it is projected to achieve sensitivity in 3–6 months due to its large mass and high statistical power.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.