[Paper Review] The diameters of Alpha Centauri A and B - A comparison of the asteroseismic and VINCI/VLTI views
This study presents the first direct interferometric measurements of the angular diameters of Alpha Centauri A and B using the VINCI instrument at the VLT Interferometer, achieving 0.2% and 0.6% relative precision, respectively. The measured limb-darkened angular diameters (8.511±0.020 mas for A, 6.001±0.034 mas for B) combined with parallax data yield linear diameters of 1.224±0.003 D⊙ and 0.863±0.005 D⊙, which are in excellent agreement with asteroseismic models that reduce the mass of component B by 3% compared to earlier estimates.
We compare the first direct angular diameter measurements obtained on our closest stellar neighbour, Alpha Centauri, to recent model diameters constrained by asteroseismic observations. Using the VINCI instrument installed at ESO's VLT Interferometer (VLTI), the angular diameters of the two main components of the system, Alpha Cen A and B, were measured with a relative precision of 0.2% and 0.6%, respectively. Particular care has been taken in the calibration of these measurements, considering that VINCI is estimating the fringe visibility using a broadband K filter. We obtain uniform disk angular diameters for Alpha Cen A and B of UD[A] = 8.314 +/- 0.016 mas and UD[B] = 5.856 +/- 0.027 mas, and limb darkened angular diameters of LD[A] = 8.511 +/- 0.020 mas and LD[B] = 6.001 +/- 0.034 mas. Combining these values with the parallax from Soderhjelm (1999), we derive linear diameters of D[A] = 1.224 +/- 0.003 Dsun and D[B] = 0.863 +/- 0.005 Dsun. These values are compatible with the masses published by Thevenin et al.(2002) for both stars.
Motivation & Objective
- To obtain the first direct measurement of the angular diameters of Alpha Centauri A and B using long-baseline optical interferometry.
- To test the consistency of asteroseismic models—particularly those predicting a 3% lower mass for component B—against direct interferometric measurements.
- To calibrate the interferometric visibility measurements using a faint, unresolved calibrator star to minimize systematic errors.
- To derive linear diameters and stellar parameters by combining interferometric angular diameters with the parallax from Söderhjelm (1999).
- To assess the impact of varying mixing length and mass in stellar models to reconcile the observed diameter with theoretical predictions for component B.
Proposed method
- Utilized the VINCI instrument at the VLT Interferometer (VLTI) to measure fringe visibility in the K-band (λ ≈ 2.178 μm) using two baselines: 16 m and 66 m.
- Employed a faint, unresolved star as a calibration source to correct for instrumental and atmospheric effects on visibility measurements.
- Measured uniform-disk (UD) and limb-darkened (LD) angular diameters from the visibility curves, using a model-independent approach.
- Applied the parallax from Söderhjelm (1999) to convert angular diameters into linear diameters in solar units.
- Compared the derived linear diameters with those predicted by asteroseismic models from Thévenin et al. (2002), which used the CESAM stellar evolution code.
- Explored model adjustments—specifically, reducing the mixing length from λ = 0.98 to 0.96 and increasing the mass of component B from 0.907 to 0.909 M⊙—to improve agreement with interferometric data.
Experimental results
Research questions
- RQ1What are the precise angular diameters of Alpha Centauri A and B as measured by long-baseline interferometry?
- RQ2How do the interferometrically derived linear diameters compare with those predicted by asteroseismic models that reduce the mass of component B by 3%?
- RQ3Can adjustments to the mixing length and mass in stellar models improve agreement between observed and predicted diameters for component B?
- RQ4To what extent does the visibility measurement precision depend on baseline length and target visibility level?
- RQ5Can the combination of interferometry and asteroseismology provide tighter constraints on fundamental stellar parameters like mass and radius?
Key findings
- The uniform-disk angular diameter of Alpha Centauri A was measured as 8.314±0.016 mas, and for B as 5.856±0.027 mas.
- The limb-darkened angular diameters were determined to be 8.511±0.020 mas for A and 6.001±0.034 mas for B.
- The linear diameters derived from the angular diameters and parallax are 1.224±0.003 D⊙ for A and 0.863±0.005 D⊙ for B.
- The interferometric diameters are in excellent agreement with the asteroseismic model of Thévenin et al. (2002), which predicts a 3% lower mass for component B compared to earlier estimates.
- Adjusting the mixing length from λ = 0.98 to 0.96 and increasing the mass of component B to 0.909 M⊙ reduces the discrepancy with the interferometric diameter, yielding a predicted diameter of 5.999±0.050 mas.
- The effective temperature of component B is confirmed as 5262 K, consistent with the spectroscopic value of 5260 K, supporting the model's reliability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.