Skip to main content
QUICK REVIEW

[Paper Review] The ESPRI project: astrometric exoplanet search with PRIMA I. Instrument description and performance of first light observations

J. Sahlmann, Thomas Henning|Archive ouverte UNIGE (University of Geneva)|Dec 10, 2012
Adaptive optics and wavefront sensingPhysics and Astronomy42 references26 citations
TL;DR

This paper presents the ESPRI project's first-light performance using PRIMA at the VLT Interferometer for high-precision astrometric exoplanet detection. It demonstrates a 30 μas astrometric precision but identifies unmonitored beamtrain components as the main source of systematic errors limiting accuracy below the required 10–100 μas for exoplanet surveys.

ABSTRACT

The ESPRI project relies on the astrometric capabilities offered by the PRIMA facility of the Very Large Telescope Interferometer for the discovery and study of planetary systems. Our survey consists of obtaining high-precision astrometry for a large sample of stars over several years and to detect their barycentric motions due to orbiting planets. We present the operation principle, the instrument's implementation, and the results of a first series of test observations. A comprehensive overview of the instrument infrastructure is given and the observation strategy for dual-field relative astrometry is presented. The differential delay lines, a key component of the PRIMA facility which was delivered by the ESPRI consortium, are described and their performance within the facility is discussed. Observations of bright visual binaries are used to test the observation procedures and to establish the instrument's astrometric precision and accuracy. The data reduction strategy for astrometry and the necessary corrections to the raw data are presented. Adaptive optics observations with NACO are used as an independent verification of PRIMA astrometric observations. The PRIMA facility was used to carry out tests of astrometric observations. The astrometric performance in terms of precision is limited by the atmospheric turbulence at a level close to the theoretical expectations and a precision of 30 micro-arcseconds was achieved. In contrast, the astrometric accuracy is insufficient for the goals of the ESPRI project and is currently limited by systematic errors that originate in the part of the interferometer beamtrain which is not monitored by the internal metrology system. Our observations led to the definition of corrective actions required to make the facility ready for carrying out the ESPRI search for extrasolar planets.

Motivation & Objective

  • To establish the astrometric performance of the PRIMA facility at the VLT Interferometer for detecting extrasolar planets via stellar barycentric motion.
  • To validate the instrument's capability for dual-field relative astrometry in the infrared K-band using bright visual binaries as test targets.
  • To identify and correct systematic errors in the interferometric beamtrain that degrade astrometric accuracy below the 10–100 μas threshold required for exoplanet detection.
  • To provide a reference framework for future ESPRI publications and users of the PRIMA facility.
  • To enable future high-precision astrometry by guiding modifications to the metrology system to monitor previously unmonitored beamtrain segments.

Proposed method

  • Conducting first-light astrometric observations on bright visual binaries (e.g., HD 10360, HD 66598) to test observation procedures and performance.
  • Implementing dual-feed relative astrometry using PRIMA’s differential delay lines, a key component developed by the ESPRI consortium.
  • Applying data reduction strategies that correct for atmospheric turbulence and instrumental drifts, including fringe tracking and phase calibration.
  • Using adaptive optics observations with NACO as an independent verification of PRIMA’s astrometric plate scale and measurements.
  • Modeling systematic errors via a beamtrain error function (Eq. 20), isolating unmonitored path differences (Δε(t)) as the dominant error source.
  • Proposing an extension of the internal metrology system to monitor beam segments beyond M9 to reduce systematic errors.

Experimental results

Research questions

  • RQ1What is the astrometric precision and accuracy of the PRIMA facility during its first-light observations?
  • RQ2What are the dominant sources of systematic error in PRIMA’s astrometric measurements, particularly in the unmonitored beamtrain?
  • RQ3How does the PRIMA astrometric plate scale compare to independent measurements from NACO adaptive optics?
  • RQ4To what extent can the current beamtrain configuration support the 10–100 μas accuracy required for detecting Jupiter-mass planets?
  • RQ5What modifications to the metrology system are necessary to achieve the required astrometric accuracy for the ESPRI exoplanet survey?

Key findings

  • The PRIMA facility achieved an astrometric precision of 30 μas, approaching theoretical limits set by atmospheric turbulence.
  • Astrometric accuracy is currently insufficient for the ESPRI project, limited by unmonitored beamtrain components not tracked by the internal metrology system.
  • Systematic errors are dominated by the non-common path term Δε(t), originating in the beamtrain between M9 and M1, which remains unmonitored.
  • Independent NACO astrometry of a 11″ binary agrees with PRIMA measurements within 13 mas, confirming the PRIMA plate scale is accurate to ~0.1%.
  • The scatter in repeated measurements over five days on a bright 11″ binary reached ~3 mas, indicating significant residual systematic errors.
  • Future improvements require extending the metrology endpoint to M2 or beyond to mitigate the largest systematic error source and enable sub-10 μas accuracy.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.