TL;DR

This paper introduces the CMRxMotion Challenge, a public benchmark dataset created by prospectively scanning 40 healthy volunteers under controlled, extreme respiratory motion conditions during cardiac MRI. The challenge evaluates model robustness in image quality assessment and left/right ventricle segmentation under varying motion artifacts, using Cohen’s kappa and Dice/Hausdorff metrics, with results from 15 test volunteers used for final offline evaluation of containerized models.

ABSTRACT

The quality of cardiac magnetic resonance (CMR) imaging is susceptible to respiratory motion artifacts. The model robustness of automated segmentation techniques in face of real-world respiratory motion artifacts is unclear. This manuscript describes the design of extreme cardiac MRI analysis challenge under respiratory motion (CMRxMotion Challenge). The challenge aims to establish a public benchmark dataset to assess the effects of respiratory motion on image quality and examine the robustness of segmentation models. The challenge recruited 40 healthy volunteers to perform different breath-hold behaviors during one imaging visit, obtaining paired cine imaging with artifacts. Radiologists assessed the image quality and annotated the level of respiratory motion artifacts. For those images with diagnostic quality, radiologists further segmented the left ventricle, left ventricle myocardium and right ventricle. The images of training set (20 volunteers) along with the annotations are released to the challenge participants, to develop an automated image quality assessment model (Task 1) and an automated segmentation model (Task 2). The images of validation set (5 volunteers) are released to the challenge participants but the annotations are withheld for online evaluation of submitted predictions. Both the images and annotations of the test set (15 volunteers) were withheld and only used for offline evaluation of submitted containerized dockers. The image quality assessment task is quantitatively evaluated by the Cohen's kappa statistics and the segmentation task is evaluated by the Dice scores and Hausdorff distances.

Motivation & Objective

  • To establish a public benchmark dataset for assessing the impact of respiratory motion on cardiac MRI image quality.
  • To evaluate the robustness of automated segmentation models under extreme respiratory motion artifacts in real-world clinical conditions.
  • To provide a standardized challenge framework with training, validation, and test sets for image quality assessment and segmentation tasks.
  • To enable comparison of deep learning models across varying levels of motion artifact severity using standardized metrics.
  • To support the development of clinically reliable AI tools for cardiac MRI despite inconsistent patient breath-holding.

Proposed method

  • Recruited 40 healthy volunteers to perform four distinct breath-hold behaviors (adhering, halving, free, and intensive breathing) during a single MRI session on a 3T scanner.
  • Acquired paired short-axis cine MRI at end-diastole and end-systole with consistent scanner and protocol to isolate respiratory motion as the variable.
  • Used radiologist-annotated image quality labels (mild, intermediate, severe motion) and manual segmentation of left ventricle, myocardium, and right ventricle for diagnostic-quality images.
  • Released training (20 volunteers) and validation (5 volunteers) data with annotations for model development and online evaluation.
  • Withheld test set (15 volunteers) for offline evaluation of containerized docker submissions to ensure fairness and reproducibility.
  • Evaluated image quality assessment using Cohen’s kappa and segmentation using Dice score and 95% Hausdorff distance with MedPy and scikit-learn implementations.

Experimental results

Research questions

  • RQ1How does respiratory motion severity affect the diagnostic quality of cardiac MRI cine images?
  • RQ2To what extent can automated image quality assessment models distinguish between mild, intermediate, and severe motion artifacts?
  • RQ3How robust are deep learning segmentation models to respiratory motion artifacts under extreme conditions?
  • RQ4Can models trained on non-artifacted data generalize to images with severe motion artifacts, and how does performance degrade?
  • RQ5What is the relative performance of different models in segmenting left ventricle, myocardium, and right ventricle under varying motion artifact levels?

Key findings

  • The CMRxMotion Challenge dataset provides a controlled, prospective benchmark with 40 volunteers and four distinct breath-hold behaviors to simulate extreme respiratory motion in cardiac MRI.
  • Image quality assessment models were evaluated using Cohen’s kappa, with rankings generated via bootstrap resampling and paired Wilcoxon tests for significance.
  • Segmentation models were evaluated using Dice scores and 95% Hausdorff distance, with final rankings computed via a 'rank then aggregate' strategy across LV, MYO, and RV structures.
  • The challenge successfully enabled offline evaluation of 15 test cases using containerized docker submissions, ensuring reproducibility and fairness.
  • The dataset and challenge framework are publicly available via Synapse and the challenge website, supporting future research in model robustness.
  • Top-performing models demonstrated improved generalization to motion artifacts, highlighting the value of stress-testing models on extreme, real-world variations.