TL;DR

This paper presents the Fluxgate-Searchcoil Merged (FSM) magnetic field data product for the MMS mission, which combines calibrated fluxgate magnetometer (FGM) and searchcoil magnetometer (SCM) data into a single, seamless level-3 dataset using a finite impulse response (FIR) filter. The method merges data at a crossover frequency of 7 Hz, where SCM noise floor drops below FGM, achieving unity signal gain and near-zero phase delay, resulting in a continuous, high-fidelity magnetic field measurement across 0.1–32 Hz with improved noise performance.

ABSTRACT

The Fluxgate-Searchcoil Merged (FSM) data product for the Magnetospheric Multiscale (MMS) mission is created by combining the level-2 science quality data from the fluxgate and searchcoil magnetometers into a single level-3 data product. The merging method involves noise floor and calibration parameters determined both on the pre- and post-flight. Here, we describe the statistical inter-calibration process as well as the merging filter.

Motivation & Objective

  • To create a unified, high-fidelity magnetic field data product by merging fluxgate and searchcoil magnetometer measurements from the MMS mission.
  • To address the challenge of combining two instruments with different noise floors, bandwidths, and response characteristics into a single continuous dataset.
  • To improve temporal and spectral fidelity of magnetic field measurements by minimizing phase delay and gain mismatch between FGM and SCM.
  • To enable more accurate scientific analysis of plasma phenomena such as magnetic reconnection and turbulence by providing a continuous, calibrated magnetic field time series.

Proposed method

  • The method begins with in-flight calibration of both FGM and SCM data to correct for gain, offset, and temperature drifts, using pre-flight transfer functions and cross-calibration with the Electron Drift Instrument (EDI).
  • A statistical noise floor analysis is performed using power spectral density (PSD) histograms across all burst files in September 2015 to identify the crossover frequency where SCM noise becomes lower than FGM noise.
  • A finite impulse response (FIR) filter is designed using windowed, truncated sinc functions: a low-pass filter with 4 Hz and 7 Hz cutoffs for FGM, and a complementary high-pass filter for SCM, with a 32 Hz anti-aliasing low-pass filter.
  • The FIR filter is constructed using Blackman and Chebychev windows to ensure smooth passbands and strong stopbands, with 40 dB attenuation within 1 Hz of the cutoff and 100 dB attenuation at half the Nyquist frequency.
  • The merged data product is formed by convolving the FIR filter with upsampled FGM data and the complementary high-pass filter with SCM data, ensuring the sum of the frequency responses is unity.
  • Phase delay and gain are evaluated using FFT-based cross-spectral analysis between FGM and SCM, with distributions of signal and noise used to validate calibration and timing accuracy.

Experimental results

Research questions

  • RQ1At what frequency does the searchcoil magnetometer's noise floor drop below that of the fluxgate magnetometer, enabling optimal data merging?
  • RQ2How can the gain and phase delay between fluxgate and searchcoil magnetometers be statistically calibrated and aligned across the full frequency band?
  • RQ3What filter design ensures seamless merging of FGM and SCM data while minimizing aliasing and preserving signal fidelity?
  • RQ4To what extent does the merged data product maintain unity gain and near-zero phase delay across the 0.1–32 Hz range, indicating high timing and amplitude accuracy?
  • RQ5How does the merged FSM product improve noise performance compared to individual FGM and SCM datasets?

Key findings

  • The crossover frequency for merging FGM and SCM data is determined to be 7 Hz, where the searchcoil magnetometer's noise floor becomes lower than that of the fluxgate magnetometer.
  • Noise gain between FGM and SCM is less than 1.0 at low frequencies, increasing above 1.0 near 7 Hz, confirming the optimal merging point where SCM's superior sensitivity takes over.
  • Signal gain remains unity (G = 1.0) across the entire 0.1–32 Hz range, indicating successful calibration and alignment of the two instruments.
  • Phase delay distributions for signal are strongly peaked at 0°, demonstrating high timing accuracy between FGM and SCM, with increasing spread only above 20 Hz due to signal-to-noise limitations.
  • The FIR merging filter achieves 40 dB attenuation within 1 Hz of the cutoff and 100 dB attenuation at approximately f_N/2, ensuring effective anti-aliasing and minimal spectral leakage.
  • Applying the merging filter to the noise floors of both instruments results in a significant reduction in overall noise within the 0.1–32 Hz interval, confirming improved performance of the FSM product.

Read this paper