Skip to main content
QUICK REVIEW

[Paper Review] The instrumental polarization of the Nasmyth focus polarimetric differential imager NAOS/CONICA (NACO) at the VLT - Implications for time-resolved polarimetric measurements of Sgr A*

Gunther Witzel, A. Eckart|arXiv (Cornell University)|Oct 22, 2010
Astrophysical Phenomena and ObservationsPhysics and Astronomy43 references28 citations
TL;DR

This paper presents a detailed model of the instrumental polarization (IP) in the NACO instrument at the VLT, using the Stokes/Mueller formalism for metallic reflections. It demonstrates that with the new calibration, polarization degree can be measured with <1% accuracy and polarization angle with ≤5° uncertainty for degrees ≥4%, confirming that prior results on Sgr A* are robust despite a 13.2° angle offset in data before autumn 2009.

ABSTRACT

We report on the results of calibrating and simulating the instrumental polarization properties of the ESO VLT adaptive optics camera system NAOS/CONICA (NACO) in the Ks-band. We use the Stokes/Mueller formalism for metallic reflections to describe the instrumental polarization. The model is compared to standard-star observations and time-resolved observations of bright sources in the Galactic center. We find the instrumental polarization to be highly dependent on the pointing position of the telescope and about 4% at maximum. We report a polarization angle offset of 13.28° due to a position angle offset of the half-wave plate that affects the calibration of NACO data taken before autumn 2009. With the new model of the instrumental polarization of NACO it is possible to measure the polarization with an accuracy of 1% in polarization degree. The uncertainty of the polarization angle is &lt; 5° for polarization degrees &gt; 4%. For highly sampled polarimetric time series we find that the improved understanding of the polarization properties gives results that are fully consistent with the previously used method to derive the polarization. The small difference between the derived and the previously employed polarization calibration is well within the statistical uncertainties of the measurements, and for Sgr A* they do not affect the results from our relativistic modeling of the accretion process.

Motivation & Objective

  • To characterize the instrumental polarization of the NACO polarimeter at the VLT, particularly in the Ks-band.
  • To quantify systematic calibration effects that could bias time-resolved polarimetric measurements of Sgr A*.
  • To improve polarization calibration accuracy for high-time-resolution observations of variable sources like Sgr A*.
  • To resolve discrepancies in polarization angle calibration due to a known offset in the wave plate position before autumn 2009.
  • To validate that previous polarimetric results on Sgr A* remain statistically robust despite calibration uncertainties.

Proposed method

  • Application of the Stokes/Mueller formalism to model polarization effects from metallic reflections in the NACO optical path.
  • Calibration using standard stars and bright Galactic center sources to constrain the instrumental polarization model.
  • Simulation and comparison of two calibration methods: the standard 'bootstrapping' method and the new, physically motivated model.
  • Use of the model to correct for a 13.2° polarization angle offset caused by a misalignment of the λ/2-wave plate relative to its header value.
  • Propagation of flux and polarization uncertainties through the calibration chain to assess statistical and systematic error budgets.
  • Validation of the model using time-resolved Ks-band light curves of Sgr A* from multiple flare events.

Experimental results

Research questions

  • RQ1What is the magnitude and pointing-dependent behavior of instrumental polarization in the NACO instrument at the VLT?
  • RQ2How do different calibration methods affect the derived polarization degree and angle in time-resolved observations of Sgr A*?
  • RQ3To what extent do systematic calibration errors, such as the wave plate offset, impact the reliability of polarimetric measurements?
  • RQ4Can the new polarization model achieve sub-1% accuracy in polarization degree and ≤5° in polarization angle for Sgr A* flares?
  • RQ5Are the previously published results on Sgr A* polarization, particularly those used in relativistic hot spot modeling, statistically robust under the improved calibration?

Key findings

  • The instrumental polarization in NACO reaches a maximum of 4% and is strongly dependent on the telescope's pointing position.
  • A systematic polarization angle offset of $13.2^ ext{circ} \pm 0.3^ ext{circ}$ was identified in NACO data taken before autumn 2009 due to a misalignment of the λ/2-wave plate.
  • The new calibration model enables polarization degree measurements with an accuracy better than 1% and polarization angle accuracy of ≤5° for polarization degrees ≥4%.
  • For total Ks-band intensities >4 mJy and polarized fluxes >1 mJy, the new calibration yields results indistinguishable from the previous 'bootstrapping' method within statistical uncertainties.
  • The improved model confirms that prior relativistic modeling of Sgr A* flares using earlier calibration data remains valid and unaffected by the new calibration.
  • A future calibration strategy involving real-time HWP offset compensation could achieve polarization accuracy at the level of a few tenths of a percent.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.