Skip to main content
QUICK REVIEW

[Paper Review] The ORGAN Experiment: An axion haloscope above 15 GHz

Ben T. McAllister, Graeme Flower|arXiv (Cornell University)|Jun 1, 2017
Dark Matter and Cosmic PhenomenaPhysics and Astronomy44 references10 citations
TL;DR

The ORGAN experiment is a microwave cavity axion haloscope operating above 15 GHz, designed to probe high-mass axions as dark matter candidates. In its pathfinding run at 26.531 GHz, it set a 90% confidence limit of $ g_{a\gamma\gamma} < 2.02 \times 10^{-12} \, \text{eV}^{-1} $, constraining axion-photon coupling near the 110 $\mu$eV mass region motivated by recent theoretical and experimental claims.

ABSTRACT

We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of $110~μ$eV. Later stages will move to a wider scan range of 15-50 GHz ($60-210~μ$eV). We present the results of the pathfinding run, which sets a limit on $g_{aγγ}$ of $2.02 imes 10^{-12} $eV$^{-1}$ at 26.531 GHz, or 110~$μ$eV, in a span of 2.5 neV (shaped by the Lorentzian resonance) with $90 \%$ confidence. Furthermore, we outline the current design and future strategies to eventually attain the sensitivity to search for well known axion models over the wider mass range.

Motivation & Objective

  • To directly test a claimed 110 $\mu$eV axion signal from Josephson junction experiments.
  • To probe the high-mass axion parameter space above 15 GHz, particularly near 26.6 GHz, which remains unexplored by most haloscopes.
  • To develop a multi-stage haloscope experiment capable of scanning 15–50 GHz with high sensitivity using a 14 T magnet and quantum-limited amplification.
  • To achieve sensitivity below the standard quantum limit through squeezed microwave states and quantum non-demolition measurements.
  • To complement existing experiments like ADMX and future projects like MADMAX by targeting the 15–50 GHz range with optimized resonator arrays.

Proposed method

  • Utilizes a resonant microwave cavity embedded in a 14 T static magnetic field to enhance axion-to-photon conversion via the inverse Primakoff effect.
  • Employs a fixed-frequency cavity (non-tunable) in the pathfinding run to achieve high Q-factor and narrow linewidth for precise coupling limit setting.
  • Applies a Lorentzian-shaped resonance function to define the effective bandwidth of 2.5 neV at 26.531 GHz.
  • Uses low-noise, cryogenic amplification systems to detect weak axion-induced microwave signals, with future plans for quantum-limited and sub-quantum-limited amplification.
  • Plans to deploy multiple small resonators (4–6) across the 15–50 GHz range to maintain effective volume utilization and enable frequency scanning.
  • Incorporates advanced quantum measurement techniques, including squeezed states and quantum non-demolition measurements, to surpass the standard quantum limit in signal detection.

Experimental results

Research questions

  • RQ1Can a haloscope experiment achieve competitive sensitivity to axions above 15 GHz, particularly in the 25–30 GHz range?
  • RQ2What is the tightest possible limit on axion-photon coupling $ g_{a\gamma\gamma} $ in the 26.5 GHz band using a fixed-frequency cavity and current technology?
  • RQ3Can quantum-limited and sub-quantum-limited amplification be practically implemented in a high-frequency axion haloscope to reach sensitivity within the DFSZ and KSVZ model bands?
  • RQ4How can resonator design and magnetic field strength be optimized to maintain high effective volume utilization across a wide frequency range (15–50 GHz)?
  • RQ5Can the ORGAN experiment provide a direct test of the claimed 110 $\mu$eV axion signal from Josephson junction anomalies?

Key findings

  • The pathfinding run achieved a 90% confidence upper limit of $ g_{a\gamma\gamma} < 2.02 \times 10^{-12} \, \text{eV}^{-1} $ at 26.531 GHz, corresponding to a 110 $\mu$eV axion mass.
  • The effective bandwidth of the resonance was 2.5 neV, shaped by the Lorentzian lineshape of the cavity, enabling high-resolution coupling constraints.
  • The result is approximately 50 times more sensitive than the KSVZ model prediction at this frequency, placing strong constraints on the axion-photon coupling strength.
  • Future stages plan to scan 15–50 GHz using multiple resonators and a 14 T magnet, with projected sensitivity reaching the DFSZ and KSVZ model bands if quantum-limited amplification is achieved.
  • Theoretical projections show that with 28 T magnets and sub-quantum-limited amplification, sensitivity could improve further, potentially probing the full range of axion models in the 15–50 GHz band.
  • The experiment is designed to remain flexible, allowing reallocation of focus to unexcluded regions should other high-mass axion experiments rule out parts of the search space.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.