[Paper Review] The outer hair cell of the organ of Corti possesses a voltage-dependent motile frequency response: evidence for the frequency-dependent compliance of prestin
This study demonstrates that outer hair cells (OHCs) exhibit a voltage-dependent motile frequency response due to prestin's frequency-dependent compliance, with electromotility (eM) attenuating above ~1.5 kHz at the half-activation voltage (Vh). The response shows a U-shaped dependence on holding voltage, increasing up to sixfold away from Vh, and is best explained by viscous drag combined with prestin's conformational kinetics, not stiffness or simple viscosity alone.
The outer hair cell (OHC) of the organ of Corti underlies a mechanically based process that enhances hearing, termed cochlear amplification. The cell possesses a unique motor protein, prestin, which senses voltage and consequently changes conformation to cause large cell length changes, termed electromotility (eM). In OHCs studied in vitro, the prestin voltage sensor generates a capacitance that is both voltage and frequency dependent, peaking in magnitude at a characteristic membrane voltage (Vh), which can be greater than the linear capacitance of the cell. Consequently, the OHC membrane time constant is multifarious depending upon resting potential and frequency of AC evaluation. After precisely correcting for this influence on the whole-cell voltage clamp time constant, we find that OHC eM is low pass in nature, substantially attenuating in magnitude within the frequency bandwidth of human speech. The frequency response is slowest at Vh, with a cut-off near 1.5 kHz, but increases up to six-fold in a U shaped manner as holding voltage deviates from Vh. NLC measures follow this pattern. Viscous drag alone cannot account for such eM behavior; nor can it arise from viscous drag in combination with a sigmoidal voltage-dependent OHC stiffness. However, viscous drag combined with kinetics of prestin, likely corresponding to its bell-shaped conformational gating compliance (Iwasa, 2000), is in line with our observations. How OHC eM influences cochlear amplification at higher frequencies needs reconsideration.
Motivation & Objective
- To investigate the frequency-dependent motile behavior of outer hair cells (OHCs) in the organ of Corti.
- To determine how voltage and frequency influence OHC electromotility (eM) and its underlying biophysical mechanisms.
- To resolve discrepancies in eM behavior at higher frequencies, particularly in relation to cochlear amplification.
- To test whether viscous drag, OHC stiffness, or prestin kinetics best explain the observed eM frequency response.
- To clarify the role of prestin's voltage-dependent conformational changes in shaping eM dynamics across physiological frequencies.
Proposed method
- Whole-cell voltage clamp recordings from isolated OHCs to measure voltage-dependent capacitance and electromotility (eM) responses.
- Precise correction for the membrane time constant's frequency and voltage dependence to isolate intrinsic eM behavior.
- Analysis of eM amplitude as a function of holding voltage and stimulus frequency to determine the frequency response profile.
- Comparison of experimental eM data with theoretical models incorporating viscous drag and prestin's conformational kinetics.
- Use of nonlinear capacitance (NLC) measurements to infer voltage-dependent changes in prestin's compliance.
- Application of Iwasa's (2000) model of prestin's bell-shaped conformational gating compliance to explain the observed U-shaped voltage dependence of eM.
Experimental results
Research questions
- RQ1How does the voltage holding potential affect the frequency response of outer hair cell electromotility?
- RQ2What is the role of prestin's voltage-dependent compliance in shaping the frequency response of OHC motility?
- RQ3Can viscous drag alone explain the observed low-pass filtering of electromotility in OHCs?
- RQ4Why does electromotility show a U-shaped dependence on holding voltage, with maximum response away from the half-activation voltage (Vh)?
- RQ5How do prestin's conformational kinetics contribute to the frequency-dependent behavior of OHC electromotility?
Key findings
- OHC electromotility (eM) exhibits a low-pass frequency response, with a cut-off frequency near 1.5 kHz when held at the half-activation voltage (Vh).
- eM magnitude increases up to six-fold as the holding voltage deviates from Vh, following a U-shaped dependence across frequencies.
- The voltage-dependent eM response cannot be explained by viscous drag alone or by a sigmoidal voltage-dependent OHC stiffness.
- The observed eM behavior is best explained by viscous drag combined with prestin's bell-shaped conformational gating compliance, as modeled by Iwasa (2000).
- The frequency response of eM is strongly influenced by the voltage-dependent time constant of the OHC membrane, which must be corrected for in voltage clamp experiments.
- These findings suggest a need to reconsider the role of OHC eM in cochlear amplification at higher frequencies, particularly in the human speech band.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.