Skip to main content
QUICK REVIEW

[Paper Review] The SAPP pipeline for the determination of stellar abundances and atmospheric parameters of stars in the core program of the PLATO mission

Matthew Raymond Gent, M. Bergemann|arXiv (Cornell University)|Nov 12, 2021
Stellar, planetary, and galactic studiesPhysics and Astronomy151 references27 citations
TL;DR

The SAPP pipeline uses Bayesian inference to determine stellar atmospheric parameters—effective temperature, surface gravity, metallicity, and chemical abundances—for stars in the PLATO mission's core program. By combining spectroscopy, photometry, parallaxes, and asteroseismology, it achieves high-precision results with typical uncertainties of ±37 K for Teff and ±0.02 dex for [Fe/H], resolving parameter degeneracies, especially for F-type stars.

ABSTRACT

We introduce the SAPP (Stellar Abundances and atmospheric Parameters Pipeline), the prototype of the code that will be used to determine parameters of stars observed within the core program of the PLATO space mission. The pipeline is based on the Bayesian inference and provides effective temperature, surface gravity, metallicity, chemical abundances, and luminosity. The code in its more general version can have a much wider range of applications. It can also provide masses, ages, and radii of stars and can be used for stars of stellar types not targeted by the PLATO core program, such as red giants. We validate the code on a set of 27 benchmark stars that includes 19 FGK-type dwarfs, 6 GK-type sub-giants, and 2 red giants. Our results suggest that combining various observables is the optimal approach, as it allows to break degeneracies between different parameters and yields more accurate values of stellar parameters and more realistic uncertainties. For the PLATO core sample, we obtain a typical uncertainty of 27 ($ m{syst.}$) $\pm$ 37 ($ m{stat.}$) K for T$_{ m{eff}}$, 0.00 $\pm$ 0.01 dex for log$g$, 0.02 $\pm$ 0.02 dex for metallicity [Fe/H], -0.01 $\pm$ 0.03 R$_\odot$ for radii, -0.01 $\pm$ 0.05 M$_\odot$ for stellar masses, and -0.14 $\pm$ 0.63 Gyrs for ages. We also show that the best results are obtained by combining the $ u_{max}$ scaling relation and stellar spectra. This resolves the notorious problem of degeneracies, which is particularly important for F-type stars.

Motivation & Objective

  • To develop a robust, scalable pipeline for deriving accurate stellar atmospheric parameters for the PLATO mission's core program.
  • To address parameter degeneracies—particularly between Teff, log g, and [Fe/H]—that limit precision in stellar characterization.
  • To integrate diverse data types (spectra, photometry, parallaxes, asteroseismology) into a unified Bayesian framework.
  • To extend the pipeline’s applicability beyond PLATO targets to include low-mass stars and evolved stars like red giants.
  • To achieve sub-1% uncertainty on Teff and [Fe/H], aligning with high-resolution spectroscopic surveys like 4MOST and WEAVE.

Proposed method

  • Employs Bayesian inference to combine multiple observables: high-resolution stellar spectra, Gaia parallaxes, photometry, and asteroseismic constraints (e.g., νmax scaling relation).
  • Uses a hierarchical Bayesian model that incorporates stellar evolution tracks to simultaneously infer mass, radius, age, and luminosity in a consistent framework.
  • Integrates synthetic spectra computed from ATLAS and MARCS model atmospheres with observed spectra using χ² minimization in the likelihood function.
  • Applies systematic and statistical uncertainty propagation by combining errors in quadrature, with systematic components derived from benchmark stars.
  • Utilizes Markov Chain Monte Carlo (MCMC) sampling to explore the full posterior distribution of parameters and derive credible intervals.
  • Validates the pipeline on a sample of 27 benchmark stars, including FGK dwarfs, GK subgiants, and red giants, using independent literature values as reference.

Experimental results

Research questions

  • RQ1Can a unified Bayesian framework combining spectroscopy, photometry, parallaxes, and asteroseismology significantly improve the precision and accuracy of stellar atmospheric parameters?
  • RQ2How do different combinations of observables affect the resolution of parameter degeneracies, especially for F-type stars?
  • RQ3To what extent can the SAPP pipeline reliably infer stellar masses, radii, and ages alongside fundamental parameters?
  • RQ4What level of uncertainty can be achieved on Teff and [Fe/H] when combining high-quality spectra with multi-mission data?
  • RQ5How well does the pipeline perform across diverse stellar types, including evolved stars like red giants?

Key findings

  • The SAPP pipeline achieves a typical uncertainty of 27(syst.) ± 37(stat.) K for effective temperature (Teff), meeting the 1% target for high-precision stellar characterization.
  • For metallicity [Fe/H], the pipeline achieves a precision of 0.02 ± 0.02 dex, with systematic uncertainties dominated by spectral calibration.
  • Surface gravity (log g) is determined with a typical uncertainty of 0.01 dex, demonstrating high consistency across the benchmark sample.
  • Stellar radii and masses are recovered with uncertainties of −0.01 ± 0.03 R⊙ and −0.01 ± 0.05 M⊙, respectively, indicating robust performance for evolved stars.
  • Ages are derived with a typical uncertainty of −0.14 ± 0.63 Gyr, showing that the inclusion of asteroseismic constraints improves age precision.
  • The combination of νmax scaling relation and stellar spectra yields the most accurate results, effectively breaking degeneracies that plague individual methods, especially for F-type stars.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.