Skip to main content
QUICK REVIEW

[Paper Review] The Status and Prospects of the Muon $g-2$ Experiment at Fermilab

A. T. Fienberg|arXiv (Cornell University)|May 13, 2019
Particle physics theoretical and experimental studiesPhysics and Astronomy7 citations
TL;DR

The Fermilab Muon $g-2$ experiment aims to measure the muon anomalous magnetic moment with 140 ppb precision, four times better than the Brookhaven E821 result, to test the 3.7σ discrepancy between experiment and Standard Model predictions. Using stored muons in a magnetic storage ring and precision NMR field monitoring, the experiment measures the anomalous precession frequency via positron energy spectra, with initial analysis of Run 1 data showing strong agreement across six independent teams, validating the analysis framework.

ABSTRACT

The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_μ$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at Brookhaven National Lab. There stands a greater than 3 standard deviations discrepancy between the Brookhaven measurement of $a_μ$ and the theoretical value predicted using the Standard Model. The Fermilab experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions. To achieve the E989 target precision, the anomalous precession frequency of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\,ppb, and the average magnetic field experienced by these stored muons must be known equally well. The muon anomalous precession frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. A suite of pulsed NMR probes continually monitors the magnetic field. This document presents the current status of the Fermilab experiment while emphasizing the ongoing analysis of the 2018 Run 1 dataset and the systematic effects that complicate it.

Motivation & Objective

  • To measure the muon anomalous magnetic moment $a_{\mu}$ with 140 ppb precision, improving on the Brookhaven E821 measurement by a factor of four.
  • To resolve or confirm the 3.7σ discrepancy between the Brookhaven measurement and the Standard Model prediction, which hints at new physics.
  • To reduce systematic uncertainties in the anomalous precession frequency and magnetic field measurement to below 70 ppb each.
  • To validate a robust, multi-team analysis framework using blinded data and independent reconstruction pipelines to ensure reliability.

Proposed method

  • Measure the anomalous precession frequency $\omega_a$ by observing the time-dependent energy spectrum of positrons from decayed muons using 24 electromagnetic calorimeters.
  • Use a suite of pulsed NMR probes—including fixed, trolley-mounted, and absolute calibration probes—to monitor the magnetic field with sub-ppb stability.
  • Apply a blinded analysis protocol where all teams fit $\omega_a$ relative to a secret reference frequency to prevent bias.
  • Model the positron detection rate using a damped oscillatory function $f(t) = Ne^{-t/\tau}[1 + A\cos(\omega_a t - \phi)]$, with energy threshold-dependent parameters.
  • Correct for beam dynamics effects such as coherent oscillations of the muon beam and beam loss, and for detector effects like pileup and time-dependent gain changes.
  • Use in-situ laser calibration to measure and remove time-dependent gain variations in the calorimeters.

Experimental results

Research questions

  • RQ1Can the anomalous precession frequency $\omega_a$ be measured with sufficient precision to reduce the total uncertainty in $a_{\mu}$ to 140 ppb?
  • RQ2Do systematic effects such as beam oscillations, pileup, and gain drifts introduce biases that exceed the 70 ppb target for systematic uncertainty?
  • RQ3Is the analysis framework robust and consistent across independent teams using different data reconstructions and correction procedures?
  • RQ4Does the initial 60-Hour Dataset analysis confirm the consistency of the measurement chain and support full Run 1 analysis?
  • RQ5Can the experiment resolve the 3.7σ discrepancy between the Brookhaven measurement and the Standard Model prediction?

Key findings

  • The six independent analysis teams achieved excellent agreement on the $\omega_a$ measurement from the 60-Hour Dataset, validating the robustness of the analysis framework.
  • The teams produced consistent estimates of systematic uncertainties, confirming that the analysis pipeline is reliable and internally consistent.
  • The optimal energy threshold for minimizing statistical uncertainty in $\omega_a$ was found to be 1.7 GeV.
  • Beam dynamics effects such as coherent oscillations of the muon beam were found to be strong and required explicit modeling in the fit function.
  • Pileup and time-dependent gain variations were corrected using in-situ laser calibration and team-specific reconstruction corrections, with no significant bias detected.
  • The blinded analysis protocol was successfully executed, and the relative unblinding in February 2019 confirmed consistency across teams, clearing the path for full Run 1 analysis.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.