[Paper Review] Time- and Angle-Resolved Photoemission Spectroscopy using an Ultrafast Extreme Ultraviolet Source at 21.8 eV
This paper presents a time- and angle-resolved photoemission spectroscopy (TR-ARPES) setup using a 21.8 eV ultrafast extreme ultraviolet source generated via high-order harmonic generation (HHG) from a 20 W Yb:KGW laser amplifier. The system achieves 320 fs time resolution and 21.5 meV energy resolution by optimizing repetition rate and photon flux, enabling direct probing of non-equilibrium band structures in ZrSiS and Sb2-xGdxTe3.
Characterizing and controlling electronic properties of quantum materials require direct measurements of non-equilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for time- and angle-resolved photoemission spectroscopy using high-order harmonic probe pulses generated by a robust, moderately high power (20 W) Yb:KGW amplifier with tunable repetition rate between 50 and 150 kHz. By driving high-order harmonic generation (HHG) with the second harmonic of the fundamental 1025 nm laser pulses, we show that single-harmonic probe pulses at 21.8 eV photon energy can be effectively isolated without the use of a monochromator. The on-target photon flux can reach 5 x 10^10 photons/second at 50 kHz, and the time resolution is measured to be 320 fs. The relatively long pulse duration of the Yb-driven HHG source allows us to reach an excellent energy resolution of 21.5 meV, which is achieved by suppressing the space-charge broadening using a low photon flux of 1.5 x 10^8 photons/second at a higher repetition rate of 150 kHz. The capabilities of the setup are demonstrated through measurements in the topological semimetal ZrSiS and the topological insulator Sb2-xGdxTe3.
Motivation & Objective
- To develop a robust, high-repetition-rate TR-ARPES system capable of probing non-equilibrium electronic band structures in quantum materials.
- To achieve high time and energy resolution using a compact, moderately high-power Yb:KGW laser-driven HHG source without requiring a monochromator.
- To suppress space-charge broadening in photoemission spectra by operating at low photon flux while maintaining high repetition rate.
- To demonstrate the technique's capability on topological semimetals and topological insulators, including ZrSiS and Sb2-xGdxTe3.
- To enable large momentum-space coverage of electronic states in non-equilibrium conditions using a single-harmonic extreme ultraviolet probe pulse.
Proposed method
- High-order harmonic generation (HHG) is driven by the second harmonic (512.5 nm) of a 1025 nm Yb:KGW laser at repetition rates between 50 and 150 kHz.
- Single-harmonic 21.8 eV extreme ultraviolet probe pulses are isolated without a monochromator by exploiting the phase-matching and spectral filtering properties of the HHG process.
- On-target photon flux reaches 5 × 10^10 photons/second at 50 kHz, with time resolution measured at 320 fs using pump-probe cross-correlation.
- Energy resolution of 21.5 meV is achieved by reducing the photon flux to 1.5 × 10^8 photons/second at 150 kHz to minimize space-charge effects.
- Angle-resolved photoemission spectroscopy is performed on ZrSiS and Sb2-xGdxTe3 to map momentum-resolved electronic band structures under non-equilibrium conditions.
- The system leverages a robust, high-average-power laser source to enable stable, high-repetition-rate operation suitable for time-resolved measurements.
Experimental results
Research questions
- RQ1Can a high-repetition-rate, high-average-power laser system generate isolated 21.8 eV extreme ultraviolet pulses suitable for time- and angle-resolved photoemission without monochromatization?
- RQ2What is the achievable time resolution in a TR-ARPES setup using a Yb:KGW laser-driven HHG source at variable repetition rates?
- RQ3How does space-charge broadening affect energy resolution, and can it be mitigated at high repetition rates by reducing photon flux?
- RQ4Can this setup resolve non-equilibrium electronic band structures in topological materials like ZrSiS and Sb2-xGdxTe3?
- RQ5What is the trade-off between photon flux, repetition rate, and energy resolution in ultrafast TR-ARPES using HHG sources?
Key findings
- The system achieves a time resolution of 320 fs using pump-probe cross-correlation, demonstrating its capability for ultrafast electronic dynamics studies.
- An energy resolution of 21.5 meV is achieved at a high repetition rate of 150 kHz by reducing the photon flux to 1.5 × 10^8 photons/second to suppress space-charge broadening.
- The on-target photon flux reaches 5 × 10^10 photons/second at 50 kHz, enabling high signal-to-noise measurements without compromising time or energy resolution.
- Isolated 21.8 eV probe pulses are generated without a monochromator, relying on intrinsic spectral filtering in the HHG process, simplifying the experimental setup.
- The technique successfully maps non-equilibrium band structures in the topological semimetal ZrSiS and the topological insulator Sb2-xGdxTe3, validating its applicability to quantum materials.
- The use of a 20 W Yb:KGW amplifier enables stable, high-repetition-rate operation over a wide range of conditions, enhancing data acquisition speed and stability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.