TL;DR

This paper proposes U-NetPlus, a modified U-Net architecture that replaces transposed convolutions with nearest-neighbor upsampling and integrates a pre-trained VGG encoder for improved surgical instrument segmentation. It achieves 90.20% DICE on binary segmentation and 76.26% on instrument part segmentation, outperforming prior methods on the MICCAI 2017 EndoVis dataset with reduced checkerboard artifacts and faster convergence.

ABSTRACT

Conventional therapy approaches limit surgeons' dexterity control due to limited field-of-view. With the advent of robot-assisted surgery, there has been a paradigm shift in medical technology for minimally invasive surgery. However, it is very challenging to track the position of the surgical instruments in a surgical scene, and accurate detection & identification of surgical tools is paramount. Deep learning-based semantic segmentation in frames of surgery videos has the potential to facilitate this task. In this work, we modify the U-Net architecture named U-NetPlus, by introducing a pre-trained encoder and re-design the decoder part, by replacing the transposed convolution operation with an upsampling operation based on nearest-neighbor (NN) interpolation. To further improve performance, we also employ a very fast and flexible data augmentation technique. We trained the framework on 8 x 225 frame sequences of robotic surgical videos, available through the MICCAI 2017 EndoVis Challenge dataset and tested it on 8 x 75 frame and 2 x 300 frame videos. Using our U-NetPlus architecture, we report a 90.20% DICE for binary segmentation, 76.26% DICE for instrument part segmentation, and 46.07% for instrument type (i.e., all instruments) segmentation, outperforming the results of previous techniques implemented and tested on these data.

Motivation & Objective

  • To address the challenge of accurate and robust surgical instrument segmentation in minimally invasive laparoscopic surgery.
  • To overcome limitations of standard U-Net, such as checkerboard artifacts from transposed convolutions and slow convergence due to random weight initialization.
  • To improve multi-class segmentation performance for instrument parts and types using a modified encoder-decoder architecture.
  • To enhance model generalization and training stability on limited medical video data through effective data augmentation and pre-trained feature extraction.
  • To demonstrate that nearest-neighbor upsampling with fixed weights improves segmentation accuracy and reduces artifacts compared to learnable deconvolution layers.

Proposed method

  • The U-NetPlus architecture replaces the transposed convolution in the decoder with a nearest-neighbor (NN) interpolation layer followed by two 3x3 convolutional layers for feature refinement.
  • A pre-trained VGG-16 or VGG-11 encoder is used to initialize the encoder path, enabling faster convergence and better feature representation.
  • Batch normalization is applied in the encoder to stabilize training and improve gradient flow.
  • A fast, flexible data augmentation technique is employed to increase training data diversity and reduce overfitting on the limited MICCAI 2017 EndoVis dataset.
  • The model is trained end-to-end on 8×225 frame sequences from robotic surgical videos, with inference performed on 8×75 and 2×300 frame sequences.
  • An attention analysis using class activation mapping visualizes where the model focuses during segmentation, demonstrating improved localization on instrument parts like wrists and claspers.

Experimental results

Research questions

  • RQ1Can replacing transposed convolutions with nearest-neighbor upsampling reduce checkerboard artifacts and improve segmentation quality in surgical instrument segmentation?
  • RQ2Does using a pre-trained VGG encoder significantly improve convergence speed and segmentation accuracy on limited surgical video data?
  • RQ3How does the combination of nearest-neighbor upsampling and pre-trained encoders affect performance in multi-class segmentation of instrument parts and types?
  • RQ4Can a fast data augmentation strategy effectively mitigate overfitting in low-data regimes typical of surgical video datasets?
  • RQ5Does the proposed architecture enable better attention localization on critical instrument components compared to standard U-Net and TernausNet?

Key findings

  • U-NetPlus achieved 90.20% DICE score on binary surgical instrument segmentation, representing a 0.21% improvement over prior methods and over 6% improvement over the original U-Net.
  • For instrument part segmentation (shaft, wrist, claspers), U-NetPlus achieved 76.26% DICE, showing consistent improvement across all three classes.
  • The U-NetPlus-VGG-11 variant outperformed U-NetPlus-VGG-16 in instrument type segmentation, achieving 46.07% DICE, indicating model architecture sensitivity to class complexity.
  • Qualitative results demonstrated that U-NetPlus produces cleaner, more precise segmentations with fewer false positives compared to U-Net, U-Net+NN, and TernausNet.
  • Attention visualization confirmed that U-NetPlus focuses more accurately on instrument components like the wrist and claspers, unlike baseline models that show diffuse or inaccurate attention.
  • The use of nearest-neighbor upsampling eliminated checkerboard artifacts commonly associated with transposed convolutions, contributing to improved visual and quantitative segmentation quality.