[Paper Review] Ultrasensitive and highly accurate long-range surface plasmon resonance biosensors based on two-dimensional transition metal dichalcogenides
This paper proposes a highly sensitive and accurate long-range surface plasmon resonance (LRSPR) biosensor using two-dimensional transition metal dichalcogenides (TMDCs) such as MoS₂, MoSe₂, WS₂, and WSe₂ as signal-enhancing and biomolecule-absorbing layers. The integration of TMDCs with a gold thin film and cytop dielectric layer enhances imaging sensitivity up to 4,244 RIU⁻¹ and detection accuracy above 135 deg⁻¹, surpassing conventional SPR and graphene-based sensors by leveraging tunable plasmonic coupling and electron transfer efficiency.
Two-dimensional transition metal dichalcogenides (TMDCs), as promising alternative plasmonics supporting materials to graphene, exhibit potential applications in sensing. Here, we propose an ultrasensitive, accurate long-range surface plasmon resonance (LRSPR) imaging biosensor with two-dimensional TMDC layers, which shows higher detection accuracy than that of conventional SPR biosensor. It is found that the imaging sensitivity of the proposed LRSPR biosensor can be enhanced by the integration of TMDC layers, which is different from the previous graphene-based LRSPR or SPR imaging sensor, whose imaging sensitivity usually decreases with the number of graphene layers. The sensitivity enhancement or degradation effect for the proposed chalcogenide-cytop-gold-TMDCs based biosensor depends on the thickness of gold thin film and cytop layer. Imaging sensitivity of more than 4000 $ ext{RIU}^{-1}$ can be obtained with a high detection accuracy of more than 120 $ ext{deg}^{-1}$. We expect that the proposed TMDCs mediated LRSPR imaging sensor could provide potential applications in chemical sensing and biosensing for a highly sensitive and accurate simultaneous detection of multiple biomolecular interactions.
Motivation & Objective
- To develop a long-range surface plasmon resonance (LRSPR) biosensor with enhanced sensitivity and detection accuracy beyond conventional SPR and graphene-based systems.
- To investigate the role of two-dimensional transition metal dichalcogenides (TMDCs) as signal-enhancing and biomolecule-absorbing layers in LRSPR sensors.
- To optimize sensor performance by tuning the thickness of the gold film and cytop dielectric layer, which critically influence sensitivity and accuracy.
- To identify the refractive index (RI) detection limit and propose material replacements (e.g., MgF₂) to extend operational range.
- To compare the performance of tungsten-based (WS₂, WSe₂) and molybdenum-based (MoS₂, MoSe₂) TMDCs for optimal sensing outcomes.
Proposed method
- The sensor structure consists of a 2S2G prism, a cytop dielectric layer, a gold (Au) thin film, and a monolayer TMDC (MoS₂, MoSe₂, WS₂, WSe₂) as the active sensing layer.
- The LRSPR mode is excited via the Kretschmann configuration using p-polarized light at a fixed incident angle, with reflectance-angle curves measured to extract resonance dip characteristics.
- Theoretical modeling uses the transfer matrix method to calculate the reflectance and electric field distribution, with sensitivity defined as the slope of the reflectance-angle curve (dθ/dn).
- Detection accuracy (DA) is quantified as the inverse of the full width at half maximum (FWHM) of the resonance dip, with higher values indicating sharper dips and better resolution.
- Sensitivity and DA are systematically analyzed by varying the Au film thickness (10–30 nm), cytop layer thickness (1.0–2.0 μm), and sensing layer refractive index (1.300–1.365).
- The performance is benchmarked against conventional SPR and graphene-based LRSPR sensors, with comparisons focusing on imaging sensitivity and detection accuracy.
Experimental results
Research questions
- RQ1How does the integration of TMDCs affect the imaging sensitivity and detection accuracy of LRSPR biosensors compared to conventional SPR and graphene-based systems?
- RQ2What is the optimal thickness of the gold film and cytop dielectric layer for maximizing sensitivity and accuracy in TMDC-based LRSPR sensors?
- RQ3How does the refractive index of the sensing layer influence the imaging sensitivity and detection accuracy of the proposed LRSPR biosensor?
- RQ4Why does the imaging sensitivity of the TMDC-based LRSPR sensor increase with sensing layer RI in case 2, unlike in case 1, and what causes the sensitivity enhancement or degradation?
- RQ5Can the refractive index detection limit of the sensor be extended by replacing the cytop layer with a higher RI dielectric such as MgF₂?
Key findings
- The proposed TMDC-based LRSPR biosensor achieves an imaging sensitivity of up to 4,244 RIU⁻¹ for monolayer MoS₂ and 4,223 RIU⁻¹ for WSe₂ at a sensing layer refractive index of 1.365.
- Detection accuracy exceeds 135 deg⁻¹ for MoS₂ and WSe₂-based sensors at the same refractive index, significantly outperforming conventional SPR and graphene-based systems.
- Sensitivity enhancement occurs when the cytop layer thickness is 1.0 μm and the Au film is 15 nm, with tungsten-based TMDCs (WS₂, WSe₂) showing higher sensitivity than molybdenum-based ones (MoS₂, MoSe₂).
- The minimum reflectance of the reflectance-angle curve is substantially reduced at higher sensing layer RIs (>1.330), improving signal-to-noise ratio and enabling higher accuracy.
- The refractive index detection limit is found to be 1.370; replacing the cytop layer with MgF₂ (RI ~1.38) can extend this limit and improve sensor range.
- The sensor performance can be further enhanced by substituting gold with silver, aluminum, or copper, which exhibit narrower SPR curves and thus higher intrinsic detection accuracy.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.