Skip to main content
QUICK REVIEW

[Paper Review] Undulator-Based Positron Source at 250 GeV CM Energy with Different Optical Matching Devices: Pulsed Flux Concentrator and Quarter Wave Transformer

Andriy Ushakov, Gudrid Moortgat‐Pick|arXiv (Cornell University)|Jan 1, 2018
Particle Accelerators and Free-Electron LasersEngineering8 references5 citations
TL;DR

This study evaluates the feasibility of a 250 GeV center-of-mass energy positron source for the International Linear Collider using a helical undulator with two optical matching devices: a pulsed flux concentrator (FC) and a quarter wave transformer (QWT). While the FC faces excessive peak energy deposition (33.3 J/g) exceeding copper’s limit, the QWT reduces this to 7 J/g and enables a safe, high-yield positron source via moderate K-value increase to 0.85, achieving 1.5 e+/e− yield with radiation damage at 0.12 dpa/year.

ABSTRACT

In the baseline design of the International Linear Collider (ILC) an undulator-based source is foreseen for the positron source. In this study the energy deposition in the pulsed flux concentrator (FC) of positron source is calculated for the ILC at 250 GeV center-of-mass energy. The peak energy of 33 J/g deposited by one beam pulse in the current design of the FC is above the limit for copper material. Several promising options were considered to solve the issue of overheating the FC: the quarter wave transformer (QWT) has a significantly bigger aperture and is considered as an valuable and safe alternative for the FC. Since the positron source with a QWT is expected to lead to a lower positron capture efficiency, also the expected positron yield was calculated in addition to the energy deposition in QWT.

Motivation & Objective

  • To assess the thermal and radiation challenges of the baseline pulsed flux concentrator (FC) in the ILC positron source at 250 GeV center-of-mass energy.
  • To evaluate the feasibility of replacing the FC with a quarter wave transformer (QWT) as a safer alternative due to higher thermal limits.
  • To determine the required undulator K-value and beam parameters to achieve a positron yield of 1.5 e+/e− using the QWT.
  • To compare positron capture efficiency and energy deposition between the FC and QWT under identical ILC 250 GeV conditions.

Proposed method

  • Used PPS-Sim (Geant4-based) to calculate positron yield, accounting for ILC damping ring acceptance (±3.4 cm × ±37.5 MeV longitudinal, 70 mm·rad transverse emittance).
  • Performed FLUKA-based simulations to evaluate energy deposition and radiation damage in both the FC and QWT components.
  • Simulated energy deposition profiles in the FC and QWT using beam parameters: 125 GeV drive beam, 1312 bunches/pulse, 5 Hz repetition rate, 231 m undulator length.
  • Optimized parameters including target thickness (reduced to 7 mm), use of a compact electron dogleg to shorten undulator-to-target distance, and application of bunch length cuts at the capture linac.
  • Evaluated the impact of varying the first QWT solenoid field (from 0.4 T to 2.2 T) on positron yield and identified optimal field strength at ~1.4 T.
  • Assessed radiation damage in the QWT via displacement damage per atom (dpa), estimating peak damage at 0.12 dpa after 5000 hours of operation.

Experimental results

Research questions

  • RQ1Can the pulsed flux concentrator (FC) at 250 GeV CM energy operate within thermal limits given its peak energy deposition of 33.3 J/g?
  • RQ2Does the quarter wave transformer (QWT) offer a viable thermal alternative to the FC, with significantly lower peak energy deposition?
  • RQ3What undulator K-value is required to achieve a 1.5 e+/e− positron yield using the QWT at 250 GeV CM energy?
  • RQ4How does the positron capture efficiency compare between the FC and QWT configurations under optimized conditions?
  • RQ5What is the annual radiation damage level in the QWT, and is it within safe operational limits?

Key findings

  • The pulsed FC exhibits a peak energy deposition of 33.3 J/g, exceeding the safe limit for copper (7–12 J/g), indicating thermal failure risk.
  • Reducing the target thickness to 7 mm and using a compact electron dogleg lowers the FC’s peak energy deposition to 25.5 J/g, still above the copper limit.
  • The QWT reduces peak energy deposition in the iron yoke to 7 J/g, well below the 12.5 J/g limit for ARMCO Pure Steel, making it a thermally viable alternative.
  • A 1.04 T QWT field achieves a positron yield of 1.5 e+/e− when the undulator K-value is increased to 0.85, matching the FC’s performance.
  • The QWT’s peak annual radiation damage is estimated at 0.12 dpa, well below the 0.5 dpa threshold, indicating long-term operational safety.
  • The QWT’s larger aperture (11 mm vs. 6.5 mm) and lower energy deposition density significantly improve thermal and mechanical robustness over the FC.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.