Skip to main content
QUICK REVIEW

[Paper Review] Unsupervised Medical Image Segmentation with Adversarial Networks: From Edge Diagrams to Segmentation Maps

Umaseh Sivanesan, Luis H. Braga|arXiv (Cornell University)|Nov 12, 2019
Generative Adversarial Networks and Image SynthesisComputer Science65 references13 citations
TL;DR

This paper proposes an unsupervised medical image segmentation method that generates synthetic training data from edge diagrams using GANs, enabling high-quality segmentation without real annotated data. It achieves state-of-the-art unsupervised performance on kidney ultrasound and skin lesion datasets, approaching supervised models with only 10% labeled data for fine-tuning.

ABSTRACT

We develop and approach to unsupervised semantic medical image segmentation that extends previous work with generative adversarial networks. We use existing edge detection methods to construct simple edge diagrams, train a generative model to convert them into synthetic medical images, and construct a dataset of synthetic images with known segmentations using variations on extracted edge diagrams. This synthetic dataset is then used to train a supervised image segmentation model. We test our approach on a clinical dataset of kidney ultrasound images and the benchmark ISIC 2018 skin lesion dataset. We show that our unsupervised approach is more accurate than previous unsupervised methods, and performs reasonably compared to supervised image segmentation models. All code and trained models are available at https://github.com/kiretd/Unsupervised-MIseg.

Motivation & Objective

  • To address the challenge of limited annotated medical image data by creating a fully unsupervised segmentation framework.
  • To leverage the geometric consistency of organs in medical images to generate realistic synthetic training data from simple edge diagrams.
  • To train a supervised segmentation model on this synthetic data and apply it to real medical images without requiring ground truth labels on real data.
  • To evaluate performance on real clinical datasets and compare against both unsupervised and supervised baselines.
  • To explore semi-supervised fine-tuning with minimal labeled data to improve segmentation accuracy.

Proposed method

  • Edge diagrams are constructed using pre-trained edge detection methods on real medical images.
  • A conditional GAN is trained to generate synthetic medical images from these edge diagrams, with corresponding segmentation maps derived from the diagrams.
  • A synthetic dataset is created by applying variations to the extracted edge diagrams to increase diversity and generalization.
  • A supervised segmentation model (U-Net or Mask-RCNN) is trained on the synthetic data with known ground truth segmentations.
  • The trained model is evaluated on real test images from kidney ultrasound and ISIC 2018 skin lesion datasets.
  • Semi-supervised fine-tuning is performed using a small subset of real labeled data to improve performance.

Experimental results

Research questions

  • RQ1Can edge diagrams be used as a strong prior to generate realistic synthetic medical images with accurate segmentation maps?
  • RQ2Can a segmentation model trained on purely synthetic data achieve competitive performance on real medical image segmentation tasks?
  • RQ3How does the performance of this unsupervised method compare to existing unsupervised and supervised approaches on real clinical datasets?
  • RQ4To what extent can a small amount of labeled real data improve the performance of the unsupervised model?
  • RQ5What are the failure modes of the unsupervised model, and how do they relate to image artifacts or complex anatomy?

Key findings

  • On the kidney ultrasound dataset, the unsupervised method achieved an F1 score of 0.81 (±0.09), mIoU of 0.69 (±0.12), and pACC of 0.90 (±0.05), outperforming previous unsupervised methods like W-net.
  • The semi-supervised version with 10% labeled data reached an F1 of 0.88 (±0.08) and mIoU of 0.80 (±0.11), approaching the performance of fully supervised U-Net (F1: 0.91, mIoU: 0.84).
  • On the ISIC 2018 skin lesion dataset, the unsupervised method achieved an F1 of 0.830, mIoU of 0.753, and th-mIoU of 0.683, outperforming prior unsupervised methods and approaching supervised baselines.
  • The model showed high specificity (0.92 for kidneys, 0.947 for skin lesions) but moderate sensitivity (0.87 and 0.835), indicating a tendency to over-segment or miss small regions.
  • Failure cases were primarily due to artifacts such as lenses or films on skin lesions, which the model incorrectly segmented instead of the underlying lesion.
  • Despite using smooth and convex edge diagrams, the model generalized to non-convex and irregular boundaries, suggesting robustness to geometric complexity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.