[Paper Review] Wire Scanners for Small Emittance Beam Measurement in Atf

H. Hayano|ArXiv.org|Aug 16, 2000
Calibration and Measurement TechniquesEngineering2 references9 citations
TL;DR

This paper presents a high-precision wire scanner system for measuring sub-micron beam emittances in the Accelerator Test Facility (ATF) damping ring. Utilizing a 50µm and 10µm gold-plated tungsten wire array with 0.5µm resolution stepping motors and radiation-hardened Magnescale position sensors, the system achieves sub-2µm horizontal and sub-0.3µm vertical beam size resolution, enabling accurate emittance measurements of εx = 1.3×10⁻⁹ m·rad and εy = 1.7×10⁻¹¹ m·rad at 1.3 GeV and 2×10⁹ electrons per bunch.

ABSTRACT

The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are ex=1.3x10-9 m.rad, ey=1.7x10-11 m.rad with 2x109 electrons/bunch intensity and 1.3GeV energy. The wire scanners scan the beam by a tungsten wire with beam repetition 0.78Hz. The scanning speed is, however, very slow(~500um/sec). Since the extracted beam is quite stable by using the double kicker system, precision of the size measurement is less than 2um for 50 - 150um horizontal beam size and 0.3um for 8 - 16um vertical beam size. The detail of the system and the performance are described.

Motivation & Objective

  • To enable precise measurement of very small beam emittances in the ATF damping ring, essential for future linear collider applications.
  • To address the challenge of measuring micron-scale vertical beam sizes (8–16µm) with high spatial resolution and stability.
  • To achieve sub-2µm resolution in horizontal beam size (50–150µm) despite slow scanning speeds.
  • To minimize measurement errors from wire tilt, beam position jitter, and dispersion effects in the beamline optics.
  • To validate emittance measurements using multiple wire scanners and cross-check with beam intensity and dispersion tuning.

Proposed method

  • A dual-wire scanner system uses 50µm and 10µm gold-plated tungsten wires mounted at 45° and 10° angles to the X-axis for 3D beam profile scanning.
  • A 5-phase stepping motor stage with 0.5µm resolution and 0.1µm repeatability drives the wire scanner at ~500µm/sec, limited by 0.78Hz beam repetition.
  • Radiation-hardened Magnescale position sensors with external electronics ensure precise, stable position feedback with 0.5µm resolution over 100mm travel.
  • Beam intensity fluctuations are corrected by normalizing wire signals to BPM-intensity readings, reducing measurement error to <0.3µm in beam size.
  • Gamma rays from beam-wire interactions are detected via a Cerenkov detector with lead converter, air light guide, and PMT, shielded to reduce noise.
  • Beam size is derived from wire scan profiles, corrected for wire diameter (quadratic effect) and projected movement direction (e.g., 1/√2 for X/Y axes).

Experimental results

Research questions

  • RQ1Can wire scanners achieve sub-2µm resolution for horizontal beam sizes of 50–150µm and sub-0.3µm resolution for vertical sizes of 8–16µm in a high-repetition, low-emittance beamline?
  • RQ2How does beam position jitter (~4.4µm) affect wire scanner measurements, and can it be mitigated with high-resolution BPMs?
  • RQ3To what extent do wire tilt, beam tilt, and dispersion (≤10mm) degrade vertical emittance measurement accuracy, and how can they be corrected?
  • RQ4What is the impact of beam intensity on measured emittance, and why does emittance growth exceed expected intrabeam effects?
  • RQ5Can a multi-scanner system with calibrated wire angles and stable motion achieve reliable emittance measurements with <2µm uncertainty?

Key findings

  • The wire scanner system achieved a horizontal beam size resolution of less than 2µm for 50–150µm beams and a vertical resolution of 0.3µm for 8–16µm beams.
  • Measured emittances were εx = 1.3×10⁻⁹ m·rad and εy = 1.7×10⁻¹¹ m·rad at 1.3 GeV and 2×10⁹ electrons per bunch, meeting ATF design targets.
  • Beam position jitter was measured at 2.4–4.4µm using high-resolution microwave BPMs, exceeding BPM resolution but below measurement error threshold.
  • The system achieved 0.5µm resolution and 0.1µm repeatability in stage motion, with wire vibration <0.3µm p.p. across 55–771 Hz clock speeds.
  • Dispersion suppression to <10mm was critical; 10mm dispersion caused a 6µm beam size increment, comparable to vertical beam size.
  • Emittance growth with increasing beam intensity exceeded predictions from intrabeam scattering, indicating unexplained growth requiring further study.

Read this paper