Professor Jongduk Baek's research lab specializes in advanced x-ray computed tomography (CT) systems, with a strong focus on noise characterization, image quality optimization, and innovative CT system design. The lab investigates fundamental noise behaviors in cone-beam and fan-beam CT, particularly through noise power spectrum (NPS) analysis, to understand spatially varying noise and its impact on image fidelity. They also explore novel imaging architectures such as multi-source inverse-geometry CT and develop advanced reconstruction techniques for low-dose and metal-artifact-prone imaging, especially in dental and small-animal applications. Their work bridges theoretical analysis, simulation, and experimental validation to enhance image quality and system performance in clinical and research settings.
Figures are computed from collected data and may differ slightly.
The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and ac
We examine the noise advantages of having a computed tomography (CT) detector whose spatial resolution is significantly better (e.g. a factor of 2) than needed for a desired resolution in the reconstructed images. The effective resolution of detectors in x-ray CT is sometimes degraded by binning cells because the small cell size and fine sampling are not needed to achieve the desired resolution (e.g. with flat panel detectors). We studied the effect of the binning process on the noise in the rec
The results from noise power analysis for local volumes and an entire volume demonstrate the spatially varying noise behavior in the reconstructed cone-beam CT images.
We present initial experimental results of a rotating-gantry multi-source inverse-geometry CT (MS-IGCT) system. The MS-IGCT system was built with a single module of 2 × 4 x-ray sources and a 2D detector array. It produced a 75 mm in-plane field-of-view (FOV) with 160 mm axial coverage in a single gantry rotation. To evaluate system performance, a 2.5 inch diameter uniform PMMA cylinder phantom, a 200 µm diameter tungsten wire, and a euthanized rat were scanned. Each scan acquired 125 views per s
We propose a framework for reconstructing accurate CT images in metal-inserted sparse-view CT. The proposed method reduces streak artifacts from both metal objects and sparse-view sampling while recovering the anatomical details, indicating the feasibility of fast-scan dental CBCT imaging.
The shape of the NPS depends on the detector lag coefficients, location of the region, and the number of views used in the reconstruction. In general, the noise correlation caused by detector lag decreased the amplitude of the NPS.
To assess the resolution performance of modern CT scanners, a method to measure the 3D MTF is needed. Computationally, a point object is an ideal test phantom but is difficult to apply experimentally. Recently, Thornton et al. described a method to measure the directional MTF using a sphere phantom. We tested this method for FDK reconstructions by simulating a sphere and a point object centered at (0.01 cm , 0.01 cm, 0.01 cm) and (0.01 cm, 0.01 cm, 10.01 cm) and compared the directional MTF esti
In CT systems which have overlap volumes that can be reconstructed with data from more than one orbit and in which the spatial frequency content of each reconstruction can be calculated, the proposed method offers improved noise performance while keeping the local exactness of data from the source with the smallest tilt angle.
<i>Objective.</i>Limited-angle computed tomography (CT) presents a challenge due to its ill-posed nature. In such scenarios, analytical reconstruction methods often exhibit severe artifacts. To tackle this inverse problem, several supervised deep learning-based approaches have been proposed. However, they are constrained by limitations such as generalization issue and the difficulty of acquiring a large amount of paired CT images.<i>Approach.</i>In this work, we propose an iterative neural recon
We propose a new framework for streak artifacts reduction when only the sparse-view CT data are given. Although we do not use any information of full-view CT data for CNN training, the proposed method achieved the highest performance in preserving fine details. By overcoming the limitation of dataset requirements on fully-supervised-based methods, we expect that our framework can be utilized in the medical imaging field.
A multi-source inverse-geometry CT (MS-IGCT) system consists of a small 2D detector array and multiple x-ray sources. During data acquisition, each source is activated sequentially, and may have random source intensity fluctuations relative to their respective nominal intensity. While a conventional 3rd generation CT system uses a reference channel to monitor the source intensity fluctuation, the MS-IGCT system source illuminates a small portion of the entire field-of-view (FOV). Therefore, it i
We propose a novel metal artifact reduction (MAR) algorithm for CT images that completes a corrupted sinogram along the metal trace region. When metal implants are located inside a field of view, they create a barrier to the transmitted X-ray beam due to the high attenuation of metals, which significantly degrades the image quality. To fill in the metal trace region efficiently, the proposed algorithm uses multiple prior images with residual error compensation in sinogram space. Multiple prior i
Conventional intraoperative computed tomography (CT) has a long scan time, degrading the image quality. Its large size limits the position of a surgeon during surgery. Therefore, this study proposes a CT system comprising of eight carbon-nanotube (CNT)-based x-ray sources and 16 detector modules to solve these limitations. Gantry only requires 45° of rotation to acquire the whole projection, reducing the scan time to 1/8 compared to the full rotation. Moreover, the volume and scan time of the sy
An inverse-geometry computed tomography (IGCT) system uses a large source array opposite a smaller detector array. A previously described IGCT reconstruction algorithm uses gridding, but this gridding step produces blurring in the reconstructed image. In this article, the authors describe a two-dimensional (2D) IGCT reconstruction algorithm without gridding. In the transverse direction, the raw data of the IGCT system can be viewed as being composed of many fan beams. Because the spacing between
The multi-source inverse-geometry CT(MS-IGCT) system is composed of multiple sources and a small 2D detector array. An experimental MS-IGCT system was built and we report initial results with 2×4 x-ray sources, a 75 mm inplane field-of-view (FOV) and 160 mm z-coverage in a single gantry rotation. To evaluate the system performance, experimental data were acquired from several phantoms and a post-mortem rat. Before image reconstruction, geometric calibration, data normalization, beam harden