Kyung Hee University · 医学
Professor Jung Min Lee's research lab specializes in the development and application of advanced wearable technologies and nanomaterials for health monitoring and biomedical applications. The lab focuses on validating the accuracy of wearable activity trackers in measuring physical activity and exploring their integration with physiological monitoring, such as heart rate. Additionally, the lab investigates novel nanomaterial architectures—particularly ZnO-graphene hybrids—for flexible, transparent, and optoelectronic devices with potential in biosensing. A parallel line of research explores combination therapies in gynecologic cancers using targeted agents and immunotherapies, emphasizing translational biomarkers and clinical efficacy.
Figures are computed from collected data and may differ slightly.
The indicators of the agreement clearly favored the BodyMedia FIT armband, but promising preliminary findings were also observed with the Fitbit Zip.
The results demonstrate that the wearable activity trackers provide an accurate measurement of HR during walking and running activities.
Purpose Data suggest that DNA damage by poly (ADP-ribose) polymerase inhibition and/or reduced vascular endothelial growth factor signaling by vascular endothelial growth factor receptor inhibition may complement antitumor activity of immune checkpoint blockade. We hypothesize the programmed death-ligand 1 (PD-L1) inhibitor, durvalumab, olaparib, or cediranib combinations are tolerable and active in recurrent women's cancers. Patients and Methods This phase I study tested durvalumab doublets in
Olaparib capsules 400mg every 12 hours on days 1 to 7/carboplatin AUC5 is safe and has activity in gBRCAm BrCa/OvCa patients. Exploratory translational studies indicate pretreatment tissue FOXO3a expression may be predictive for response to therapy, requiring prospective validation.
We report ZnO nanorod−graphene hybrid architectures (ZnO−G HAs) composed of regular arrays of ZnO nanorods formed on few-layer graphene films transferred to transparent and/or flexible substrates. The ZnO−G HAs exhibited a high current flow reaching ∼1.1 mA at an applied bias of 1 V and good optical transmittance in the range of 70−80%, comparable to those of a graphene layer. In addition, cathodoluminescence images and photoluminescence spectra of the ZnO−G HAs showed distinct light emission in
Wearable activity trackers have become popular for tracking individual's daily physical activity, but little information is available to substantiate the validity of these devices in step counts. Thirty-five healthy individuals completed three conditions of activity tracker measurement: walking/jogging on a treadmill, walking over-ground on an indoor track, and a 24-hour free-living condition. Participants wore 10 activity trackers at the same time for both treadmill and over-ground protocol. Of
An adrenal incidentaloma is an adrenal mass found in an imaging study performed for other reasons unrelated to adrenal disease and often accompanied by obesity, diabetes, or hypertension. The prevalence and incidence of adrenal incidentaloma increase with age and are also expected to rise due to the rapid development of imaging technology and frequent imaging studies. The Korean Endocrine Society is promoting an appropriate practice guideline to meet the rising incidence of adrenal incidentaloma
We report a type of device that combines vertical arrays of one-dimensional (1D) pillar-superlattice (PSL) structures with 2D graphene sheets to yield a class of light emitting diode (LED) with interesting mechanical, optical, and electrical characteristics. In this application, graphene sheets coated with very thin metal layers exhibit good mechanical and electrical properties and an ability to mount, in a freely suspended configuration, on the PSL arrays as a top window electrode. Optical char
Tracking physical activity and sleep patterns using wearable trackers has become a current trend. However, little information exists about the comparability of wearable trackers measuring sleep. This study examined the comparability of wearable trackers for estimating sleep measurement with a sleep diary (SD) for three full nights. A convenience sample of 78 adults were recruited in this research with a mean age of 27.6 ± 11.0 years. Comparisons between wearable trackers and sleep outcomes were
Brooke, SM, An, H-S, Kang, S-K, Noble, JM, Berg, KE, and Lee, J-M. Concurrent validity of wearable activity trackers under free-living conditions. J Strength Cond Res 31(4): 1097-1106, 2017-The purpose of this study is to evaluate the concurrent validity of wearable activity trackers in energy expenditure (EE) and sleep period time (SPT) under free-living conditions. Ninety-five (28.5 ± 9.8 years) healthy men (n = 34) and women (n = 61) participated in this study. The total EE and SPT were measu
We demonstrate a promising molecular design approach to achieve short exciton lifetime, small singlet and triplet energy splitting and high photoluminescence quantum yield in thermally activated delayed fluorescence emitters for high quantum efficiency and low efficiency roll-off characteristics in OLEDs.
Open papers in the app to read, cite, and organize with AI.