東北大学 · 医学
本研究室では、がんの微小環境における酸素濃度の空間的・時間的変動が腫瘍細胞の挙動に与える影響を、マイクロ流体デバイスを用いて精密に制御・解析する研究を推進しています。特に、腫瘍マイクロ環境の再現とその動的変化をリアルタイムで観察可能な新規デバイスの開発が柱であり、がんの転移や血管透過性のメカニズム解明に貢献しています。また、超音波測定を統合した数値シミュレーション技術を応用し、血流の速度場・圧力場の高精度再現にも取り組んでいます。
Figures are computed from collected data and may differ slightly.
Cells in a tumor microenvironment are exposed to spatial and temporal variations in oxygen tension due to hyperproliferation and immature vascularization. Such spatiotemporal oxygen heterogeneity affects the behavior of cancer cells, leading to cancer growth and metastasis, and thus, it is essential to clarify the cellular responses of cancer cells to oxygen tension. Herein, we describe a new double-layer microfluidic device allowing the control of oxygen tension and the behavior of cancer cells
Endothelial permeability has been extensively investigated in the context of pathologies such as cancer and also in studies of drug delivery from the circulation. Hypoxia is a critical regulator of endothelial cell (EC) behavior and affects the barrier function of endothelial linings, yet its role has been little studied. This paper reveals the effect of hypoxia on the permeability of an EC monolayer by cellular experiments using a microfluidic device and a conventional cell culture dish. Human
Cancer metastasis, which is prevalent in malignant tumors, is present in a variety of cases depending on the primary tumor and metastatic site. The cancer metastasis is affected by various factors that surround and constitute a tumor microenvironment. One of the several factors, oxygen tension, can affect cancer cells and induce changes in many ways, including motility, directionality, and viability. In particular, the oxygen tension gradient is formed within a tumor cluster and oxygen is lower
Ultrasonic-measurement-integrated (UMI) simulation of blood flow is used to analyze the velocity and pressure fields by applying feedback signals of artificial body forces based on differences of Doppler velocities between ultrasonic measurement and numerical simulation. Previous studies have revealed that UMI simulation accurately reproduces the velocity field of a target blood flow, but that the reproducibility of the pressure field is not necessarily satisfactory. In the present study, the re
Understanding the mechanisms of cancer development and metastasis requires comprehensive analyses of interactions between normal and tumor cells and the extracellular matrix (ECM) in hypoxic tumor microenvironments. However, the scope of many tumor microenvironment studies is limited to verifying the development and performance of microenvironment-producing cell culture platforms. This study describes the effects of co-culture and hypoxia on contraction and degradation of the ECM. Collagen type
The complicated relationships between hemodynamics and aneurysms have been investigated intensively. However, existing methodologies have inherent limitations in providing real blood flow fields. The authors have proposed Ultrasonic-Measurement-Integrated (UMI) simulation, in which the feedback signals lead to convergence of the calculated blood flow structure to the real one even with incorrect boundary/initial conditions. In UMI simulation, determination of the feedback law is substantially im
Ultrasonic-measurement-integrated (UMI) simulation, in which feedback signals are applied to the governing equations based on errors between ultrasonic measurement and numerical simulation, has been investigated for reproduction of the blood flow field. However, ultrasonic measurement data inherently include some errors. In this study, the effects of four major measurement errors, namely, errors due to gaussian noise, aliasing, wall filter, and lack of data, on UMI simulation were examined by a
Detailed information of real blood flows is essential to develop an accurate diagnosis or treatment for serious circulatory diseases such as aortic aneurysms. Ultrasonic-Measurement-Integrated (UMI) simulation, in which feedback signals from the ultrasonic measurement make the simulation converge to the real blood flow, is a key to solving this problem. However, aliasing in the ultrasonic blood velocity measurement causes UMI simulation to converge to an erroneous result. In this paper, we have
The vascular endothelial cells constitute the innermost layer. The cells are exposed to mechanical stress by the flow, causing them to express their functions. To elucidate the functions, methods involving seeding endothelial cells as a layer in a chamber were studied. The chambers are known as parallel plate, T-chamber, step, cone plate, and stretch. The stimulated functions or signals from endothelial cells by flows are extensively connected to other outer layers of arteries or organs. The coc
Despite vast improvement in perinatal care during the 30 years, the incidence rate of neonatal encephalopathy remains unchanged without any further Progress towards preventive strategies for the clinical impasse. Antenatal brain injury including fetal intracranial hemorrhage caused by ischemia/reperfusion is known as one of the primary triggers of neonatal injury. However, the mechanisms of antenatal brain injury are poorly understood unless better predictive models of the disease are developed.
Open papers in the app to read, cite, and organize with AI.