岸崎清隆教授の研究室は、心血管疾疾患の治療を支援する革新的な医療機器の開発と評価を柱としています。特に、生体に近い環境を再現するバイオリアクターを用いた小動脈の人工組織工学や、AIを活用した画像診断支援システムの規制的・臨床的妥当性の解明が進んでいます。また、下腿動脈閉塞症に対する治療デバイスの有効性や、心房細動における射頻 treff法の解剖学的要因の解明など、臨床的ニーズに即した革新的なデバイス開発とその評価手法の確立を目指しています。
Figures are computed from collected data and may differ slightly.
A robust and elastic small-diameter artery was engineered from three types of vascular cells using the physiological pulsatile bioreactor.
The development of computer-aided detection (CAD) using artificial intelligence (AI) and machine learning (ML) is rapidly evolving. Submission of AI/ML-based CAD devices for regulatory approval requires information about clinical trial design and performance criteria, but the requirements vary between countries. This study compares the requirements for AI/ML-based CAD devices approved by the US Food and Drug Administration (FDA) and the Pharmaceuticals and Medical Devices Agency (PMDA) in Japan.
This meta-analysis aimed to evaluate the device performance of conventional balloon catheters (POBA), drug-coated balloons (DCB), bare-metal stents (BMS), and drug-eluting stents (DES) in below-the-knee (BTK) ischemic lesions with regard to lesion characteristics. Online searches of PubMed, Web of Science, and Cochrane databases (2010-2019) were conducted for each of the test devices. Primary patency rates (pp) and major amputation rates 1 year after the use of each device were analyzed using a
This study elucidated several key anatomical features of PVs possibly affecting acute success, AF recurrence and complications in patients with AF using cryoballoon ablation. CT analysis has helped to describe benefits and anatomical limitations for cryoballoon ablation.
Neoadjuvant gemcitabine and carboplatin showed less non-hematologic toxicity than methotrexate, vinblastine, doxorubicin and cisplatin, and especially less nephrotoxicity was demonstrated for gemcitabine and carboplatin. Although observed during the short term, the recurrence-free survival for gemcitabine and carboplatin was comparable to that for methotrexate, vinblastine, doxorubicin and cisplatin.
The goal of this research is to establish a reliable methodology for accelerated fatigue tests of prosthetic heart valves. A polymer valve was the subject, and the influence of various drive parameters on durability was investigated in three different machines. Valve lifetime was notably shortened by increasing the cyclic rate or stroke even though the maximum pressure difference at valve closure was maintained at 120 mm Hg. These results demonstrate that adjustment of the maximum transvalvular
The method presented here was effective in quantitatively assessing time-dependent phenomena of thrombus formation at the connector-tube interface. The method may contribute to the assessment of thrombogenicity of a novel design of connector.
Primary transcripts of retroviruses contain two poly(A) sites, one near the 5' and one near the 3' end of the transcript, but only the 3' poly(A) site is used for 3' end formation of viral RNA. It was hypothesized on the basis of experiments with U3-deleted vectors of spleen necrosis virus that the U3 region contains sequences required for this RNA 3' end formation: the titer of a U3-deleted vector was 150 times lower than that of the parental vector, and the addition of the simian virus 40 poly
The final goal of this study is to realize a low-cost pulsatile blood pump especially for patients with acute heart failure or postoperative low cardiac output syndrome. In support of the pump, two types of polymer bileaflet valves with different configuration of the valve seats were developed. Influence of the leaflet thickness on the hydrodynamics of the prototype was preliminarily investigated among 70 microm, 100 microm, and 150 microm. As to the valves with the thinner leaflets, buckling of
In a previous communication, we reported a leaflet fracture in a Jellyfish valve that was incorporated into a blood pump, after a 312-day animal implant duration. Subsequent finite element analysis revealed that the fracture location was consistent with an area of maximum strain concentration. Therefore, the aim of this study was to improve the durability in the light of these findings. Based on the engineering analysis results, a new valve seat having a concentric ring of 0.5-mm width, located