名古屋大学 · 工学
Kotaro Takamure教授の研究室では、流体工学分野に焦点を当て、乱流・混合層の構造解明や、界面現象、空気・粒子の流れ制御、ウイルスの不活化技術の開発を進めています。特に、数値シミュレーションと実験を融合したアプローチにより、流れの中での運動量輸送や、エアカーテン、ウイルス不活化ユニット、水中の物体挙動といった実用的応用に結びつく現象のメカニズムを解明しています。
Figures are computed from collected data and may differ slightly.
In this study, we performed a direct numerical simulation (DNS) of a spatially developing shear mixing layer covering both developing and developed regions. The aim of this study is to clarify the driving mechanism and the vortical structure of the partial counter-gradient momentum transport (CGMT) appearing in the quasi self-similar region. In the present DNS, the self-similarity is confirmed in x/L ≥ 0.67 (x/δU0 ≥ 137), where L and δU0 are the vertical length of the computational domain and th
Submerged solid spheres with specific gravities relative to water ranging from 1.36 to 7.93 were launched vertically upward toward the free surface of calm water. The motion of each sphere and the behavior of the water surface were investigated from the time the sphere passed through the calm water surface until it attained its maximum displacement position. The energy lost in the interaction between the sphere and the water surface (i.e., the interfacial containing energy Eo) was estimated from
A desktop-type air curtain system (DACS) capable of being installed on a desk to protect healthcare workers from infectious diseases was developed. Pseudo-exhaled air containing aerosol particles emitted from a mannequin was blown toward the air curtain generated by the DACS. The aerosol blocking effect of the DACS was investigated using particle image velocimetry measurements. A scenario in which the arm of a patient in the blood collection room is placed on the gate of the DACS was also invest
Generation of homogeneous isotropic turbulence was attempted using an innovative "multifan wind tunnel" with 99 fans installed. The driving method used is based on a principle that the shear layers generated between outflows from the adjacent ducts lead to turbulent flow downstream. First, a signal composed of two frequency components is set, and then it is fed to all the fans for three kinds of arrangements of phases. Here, parameter N is introduced as the number of phases used for the 99 fans,
A general-purpose virus inactivation unit that can inactivate viruses was developed using deep ultraviolet (DUV) LEDs that emit DUV rays with a wavelength of 280 nm. The inside of the virus inactivation unit is a rectangular conduit with a sharp turn of 180° (sharp-turned rectangular conduit). Virus inactivation is attempted by directly irradiating the air passing through the conduit with DUV rays. The flow characteristics of air and virus particles inside the virus inactivation unit were invest
Wake flows have significant effects on vehicles, buildings, and other objects encountered in daily life. Thus, wake control techniques are of practical importance and have been extensively investigated. One passive wake-control technique is to create a vent on a bluff body, which has been determined to be effective for wake control on a circular cylinder but has not been sufficiently studied for wake control on a sphere. Therefore, this study examined the effect of the vent angle on the characte
In this study, the wake characteristics of a sphere with a uniaxial through-hole (that is, vented sphere) and that of a sphere without a through-hole (that is, basic sphere) are investigated to clarify the effect of the uniaxial through-hole on the vortex shedding in the wake. A sphere with a diameter of 25.4 mm having a 6 mm circular uniaxial through-hole was fixed to the test section of the wind tunnel and arranged perpendicularly to the streamwise direction. Results show that the vented spher
A non-filter virus inactivation unit was developed that can control the irradiation dose of aerosolized viruses by controlling the lighting pattern of a 280 nm deep-UV (DUV)-LED and the air flowrate. In this study, the inactivation properties of aerosolized SARS-CoV-2 were quantitatively evaluated by controlling the irradiation dose to the virus inside the inactivation unit. The RNA concentration of SARS-CoV-2 remained constant when the total irradiation dose of DUV irradiation to the virus exce
Open papers in the app to read, cite, and organize with AI.