東北大学 · 物理学・天文学
Noriyuki Kadoya教授の研究室は、がん治療における画像診断と放射線治療計画の高度化を目的として、主に医用画像処理と深層学習を応用した研究を進めています。特に、画像登録(DIR)の精度向上や、患者個別QA(品質保証)のための深層学習ベースの線量分布予測に注力しており、臨床応用に直結する実用的で信頼性の高い技術開発を推進しています。また、3Dプリンティングを用いた評価用パラダイムの構築により、画像登録の空間的誤差を定量的に評価する基盤を整えています。
Figures are computed from collected data and may differ slightly.
We developed a CNN-based prediction model for patient-specific QA of dose distribution in prostate treatment. Our results suggest that deep learning may provide a useful prediction model for gamma evaluation of patient-specific QA in prostate treatment planning.
We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical landmarks that had been manually identified. Expert landmark correspondence was used for evaluating DIR sp
The purpose of the study was to compare a 3D convolutional neural network (CNN) with the conventional machine learning method for predicting intensity-modulated radiation therapy (IMRT) dose distribution using only contours in prostate cancer. In this study, which included 95 IMRT-treated prostate cancer patients with available dose distributions and contours for planning target volume (PTVs) and organs at risk (OARs), a supervised-learning approach was used for training, where the dose for a vo
Our results suggest that the training of the deep learning-based quality assurance model can be performed using a dummy target plan.
Our developed phantom enabled the evaluation of spatial DIR accuracy for the female pelvic region for the first time. Although the DSCs are high, the spatial errors can still be significant and our developed phantom facilitates their quantification. Our results showed that optimization is needed to identify suitable DIR settings. For determining suitable DIR settings, our method of evaluating spatial DIR accuracy using the 3D-printed phantom may prove helpful.
This study aimed to evaluate the performance of the hybrid deformable image registration (DIR) method in comparison with intensity-based DIR for pelvic cone-beam computed tomography (CBCT) images, using intensity and anatomical information. Ten prostate cancer patients treated with intensity-modulated radiation therapy (IMRT) were studied. Nine or ten CBCT scans were performed for each patient. First, rigid registration was performed between the planning CT and all CBCT images using gold fiducia
A multi-task CNN model for detecting errors in patient-specific VMAT QA using a cylindrical measuring device was constructed, and its performance was evaluated. Our results demonstrate that our model was effective in identifying the error type in the dose map for VMAT QA.
Prediction performance using homology-based radiomic features had a comparable or slightly higher prediction power than standard radiomic features. These findings suggest that homology-based radiomic features may have great potential for improving the prognostic prediction accuracy of CT-based radiomics. In this result, it is noteworthy that there are some limitations.
We evaluated dose-volume histogram (DVH) parameters based on deformable image registration (DIR) between brachytherapy (BT) and external beam radiotherapy (EBRT) that included a center-shielded (CS) plan. Eleven cervical cancer patients were treated with BT, and their pelvic and CS EBRT were studied. Planning CT images for EBRT and BT (except for the first BT, used as the reference image) were deformed with DIR to reference image. We used two DIR parameter settings: intensity-based and hybrid. M
Open papers in the app to read, cite, and organize with AI.