[論文レビュー] Development of a one-dimensional position sensitive detector for Compton X-ray polarimeters

Abhay Kumar, Santosh V. Vadawale|arXiv (Cornell University)|Mar 26, 2026
Particle Detector Development and Performance被引用数 0
ひとこと要約

この論文は、硬X線コンプトン偏光計(CXPOL)のために、1-Dの相互作用位置とエネルギー測定を実現するSiPM搭載のNaI(Tl)発光体吸収体を二端で読み出す構成を提示します。

ABSTRACT

The scientific potential of X-ray polarimetry has long been recognized, but the challenges in measuring polarization have left it largely unexplored, particularly in the hard X-ray regime. While tremendous advancement has been made in soft X-ray polarimetery, the lack of sensitive hard X-ray polarimeters and polarisation measurements continues to limit our understanding of high-energy astrophysical processes. With the development of hard X-ray mirrors, it is now possible to develop a sensitive focal plane hard X-ray polarimeter. One such effort is CXPOL, a prototype developed at PRL, India, which consists of a plastic scintillator as active scatterer readout by PMT surrounded by CsI(Tl) scintillators in cylindrical array with SiPM readout from one side. First results of the prototype have been demonstrated in 20 to 80 keV energy range. The sensitivity of the instrument can be significantly enhanced using faster and better light yield scintillator like NaI as absorbers. Further, the use of a position-sensitive scatterer and absorbers, can also provide spectroscopic information by measuring the interaction position along the length and from the known energy depositions in the detectors. Position sensitive detectors are also helpful in mitigating the systematic effects introduced by the off-axis events in the polarisation measurements. Here, we demonstrate the detection sensitivity in the 100x20x5 mm^3 NaI(Tl) scintillator absorber readout on both ends by SiPM arrays operating in co-incidence. In this work, we characterize the first prototype of this detector system and investigate the variation in energy and position resolution, and light output with irradiation position along the length of the detector. The two end readout in co-incidence also reduces the overall SiPM background per absorber by an order of magnitude, further enhancing the polarimetric sensitivity of the instrument.

研究の動機と目的

  • 硬X線偏光計測の動機づけと20–80 keVレンジでのスペクトロ偏光能力の必要性。
  • 偏光測定を改善しスペクトル情報を提供する1-D位置依存の吸収体検知器の開発。
  • 全長の感度を確保するためCsI(Tl)吸収体をNaI(Tl)へ置換し、両端SiPM読出しを実装。
  • Am-241 59.54 keV光子を用いた発光体長に沿った検出器性能のデモンストレーション。
  • 同時測定モードにおけるエネルギー分解能、位置決定、効率、背景抑制の評価。

提案手法

  • CsI(Tl)吸収体をNaI(Tl)へ置換して光量と減衰時間を向上。
  • 100×20×5 mm3 NaI(Tl)結晶の両端に2つのSiPMアレイを配置し、端-端の信号比ADC2/(ADC1+ADC2)で1-D位置を取得。
  • 結晶端部を石英窓と光学ゲルでSiPMへ結合し、光収集を改善。
  • 充電容量-感度前置増幅器/整形回路とFPGAベースの同時検出/ピーク検出チェーンを用いた2-board読み出しを開発、1 μsのタイミングウィンドウを設定。
  • 中心部照射とAm-241同時測定を用いたゲイン対称性の較正によって両端のADCゲインを補正。
  • 端信号の和(ADC1+ADC2)でエネルギーを解析し、59.54 keVとヨウ素の逸出ピークのスペクトルを2つのガウスでフィット。

実験結果

リサーチクエスチョン

  • RQ1二端構成の1-D位置依存NaI(Tl)吸収体は、硬X線偏光測定において結晶長さ方向の均一な感度を提供できるか。
  • RQ220–80 keV帯におけるデュアルエンドSiPM読出しで達成可能なエネルギー分解能、位置精度、同時測定効率はどの程度か。
  • RQ3二端同時測定読出しはSiPM背景と全体的な偏光感度にどう影響するか。
  • RQ4約20 keVの閾値と背景抑制を達成するために必要な最適化(結晶、ラッピング、光学系、電子回路)は何か。

主な発見

  • 59.54 keVのエネルギーセントロイドはSiPM端の近くで高く、中心部で低いことを示し、長さ方向の光収集変動を示唆。
  • 59.54 keVにおけるエネルギー分解能は端で約30%、中心で約40%、長さ方向全体で平均約34%。
  • 1-D位置決定の平均解像度は約1.55 cmで、端部付近は約1.04–1.09 cm。
  • 二端同時測定はSiPM背景を約10分の1に抑制し、偏光感度を向上。
  • 二端同時測定モードで長さ方向の60 keVで相対検出効率が60%以上を達成。