염진섭 교수
Jin Sup Yeom
서울대학교 · 의학
연구실 소개
염진섭 교수의 연구실은 척추외과 수술의 정밀도와 안정성을 높이기 위한 로봇 보조 척추 고정 수술 기술 개발에 주력하고 있습니다. 특히, 척추 pedicle screw 고정의 정확도 향상과 합병증 최소화를 위한 질적 모니터링 방법(예: CUSUM 분석)도 함께 연구하고 있습니다. 또한 척추질환의 병태생리학적 기전을 규명하고, 척추 디스크의 퇴행성 손상에 대한 생물학적 치료 전략(예: 혈소판풍부혈장)의 효과를 실험적으로 평가하고 있습니다.
연구 현황
연구 성과 추이
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
주요 논문
15e analysed the CT scans and radiographs of 76 vertebrae in 49 patients who underwent vertebroplasty for painful osteoporotic compression fractures. Leaks of cement were classified into three types: those via the basivertebral vein (type B), via the segmental vein (type S), and through a cortical defect (type C). More leaks were identified on CT scans than on radiographs by a factor of 1.5 (74/49). Most type-B (93%) and type-S (86%) leaks were missed or underestimated on a lateral radiograph whic
Robotic-assisted pedicle screw placement was associated with fewer proximal facet joint violations and better convergence orientations.
For treatment of single or dual spinal lesions, observation with or without bracing seems to be sufficient. In patients with multifocal lesions, chemotherapy produces good results. For treatment of neurologic deficit, low-dose radiotherapy is favored. Patients who underwent surgery--especially curettage and anterior fusion--had the worst outcome.
First, this study demonstrates the adequacy of quality control of robot-assisted pedicle screw fixation even early in the application period based on the CUSUM analysis. Second, the CUSUM test can be a useful tool for monitoring of the quality of procedures related with spine surgery.
The purpose of this study was to investigate the anti-inflammatory effect of platelet-rich plasma (PRP) with collagen matrix on human nucleus pulposus (NP) cell in response to pro-inflammatory cytokines such as tumor necrosis factor-alpha (TNF-α) and interleukin-1 (IL-1). NP cells from human disks were cultured in a monolayer and maintained in the collagen matrix prior to the addition of recombinant human IL-1 and TNF-α. After applying IL-1 and TNF-α, PRP prepared by using a commercially availab
Although vertebral artery groove and foramen violations were relatively common on postoperative CT scans, none were detected intraoperatively or on postoperative radiographs. Most alarmingly, 1 vertebral artery injury was undetected intraoperatively. Since a vertebral injury can be potentially catastrophic, this study emphasizes the inherent dangers associated with placement of C1 and C2 screws and underscores the importance of careful postoperative evaluation and surgical technique when inserti
3.
대표 연구 분야
염진섭 교수의 연구를 Nubint에서 더 깊이 살펴보세요
이 연구실의 논문을 앱에서 열어 AI와 함께 읽고, 핵심을 요약하고, 내 글에 인용하세요.