강승균 교수
Kang, Seung-Kyun
서울대학교 Department of Materials Science and Engineering · 공학
연구실 소개
강승균 교수의 연구실은 생분해 가능한 전자소자를 중심으로, 생체 내에서 완전히 용해되거나 분해되는 '순환 전자소재' 기술을 개발하고 있습니다. 주로 실리콘 산화물, 질화물, 게르마늄 및 생분해성 폴리머를 활용한 생체 적합성과 제어된 분해 속도를 확보하는 데 초점을 맞추고 있으며, 의료용 임플란트, 환경 센서, 데이터 보안 장치 등에 적용 가능한 신개념 전자 시스템을 연구하고 있습니다. 특히 약물 방출 장치와 연계한 무선 제어 기반 생분해 전자 플랫폼 개발도 진행 중입니다.
연구 현황
연구 성과 추이
표시된 성과는 수집된 데이터 기준으로 산출되며, 일부 차이가 있을 수 있습니다.
주요 논문
15Silicon oxides and nitrides are key materials for dielectrics and encapsulation layers in a class of silicon‐based high performance electronics that has ability to completely dissolve in a controlled fashion with programmable rates, when submerged in bio‐fluids and/or relevant solutions. This type of technology, referred to as “transient electronics”, has potential applications in biomedical implants, environmental sensors, and other envisioned areas. The results presented here provide comprehen
Recent advances in materials chemistry establish the foundations for unusual classes of electronic systems, characterized by their ability to fully or partially dissolve, disintegrate, or otherwise physically or chemically decompose in a controlled fashion after some defined period of stable operation. Such types of "transient" technologies may enable consumer gadgets that minimize waste streams associated with disposal, implantable sensors that disappear harmlessly in the body, and hardware-sec
Semiconducting materials are central to the development of high-performance electronics that are capable of dissolving completely when immersed in aqueous solutions, groundwater, or biofluids, for applications in temporary biomedical implants, environmentally degradable sensors, and other systems. The results reported here include comprehensive studies of the dissolution by hydrolysis of polycrystalline silicon, amorphous silicon, silicon-germanium, and germanium in aqueous solutions of various
Biodegradable substrates and encapsulating materials play critical roles in the development of an emerging class of semiconductor technology, generally referred as “transient electronics”, whose key characteristic is an ability to dissolve completely, in a controlled manner, upon immersion in ground water or biofluids. The results presented here introduce the use of thin foils of Mo, Fe, W, or Zn as biodegradable substrates and silicate spin‐on‐glass (SOG) materials as insulating and encapsulati
Implantable drug release platforms that offer wirelessly programmable control over pharmacokinetics have potential in advanced treatment protocols for hormone imbalances, malignant cancers, diabetic conditions, and others. We present a system with this type of functionality in which the constituent materials undergo complete bioresorption to eliminate device load from the patient after completing the final stage of the release process. Here, bioresorbable polyanhydride reservoirs store drugs in
Abstract Bioresorbable electronic systems represent an emerging class of technology of interest due to their ability to dissolve, chemically degrade, disintegrate, and/or otherwise physically disappear harmlessly in biological environments, as the basis for temporary implants that avoid the need for secondary surgical extraction procedures. Polyanhydride‐based polymers can serve as hydrophobic encapsulation layers for such systems, as a subset of the broader field of transient electronics, where
Transient electronics, which can be tuned to be completely or partially dissoluble, degradable, and disintegrable, create new opportunities in the upcoming ubiquitous electronics era that are inaccessible with conventional permanent electronics. This emerging field offers unique electronic applications in environmentally degradable eco-devices with minimal or zero waste, biodegradable medical implants not requiring secondary removal surgery, and hardware-based security devices with self-destruct
Real-time monitoring of infinitesimal deformations on complex morphologies is essential for precision biomechanical engineering. While flexible strain sensors facilitate real-time monitoring with shape-adaptive properties, their sensitivity is generally lower than spectroscopic imaging methods. Crack-based strain sensors achieve enhanced sensitivity with gauge factors (GFs) exceeding 30,000; however, such GFs are only attainable at large strains exceeding several percent and decline below 10 for
Biodegradable electronics are disposable green devices whose constituents decompose into harmless byproducts, leaving no residual waste and minimally invasive medical implants requiring no removal surgery. Stretchable and flexible form factors are essential in biointegrated electronic applications for conformal integration with soft and expandable skins, tissues, and organs. Here a fully biodegradable MgZnCa metallic glass (MG) film is proposed for intrinsically stretchable electrodes with a hig
대표 연구 분야
강승균 교수의 연구를 Nubint에서 더 깊이 살펴보세요
이 연구실의 논문을 앱에서 열어 AI와 함께 읽고, 핵심을 요약하고, 내 글에 인용하세요.