This paper proposes a 3D convolutional neural network (CNN) for automated segmentation of abdominal aortic aneurysms (AAA) in preoperative and postoperative CTA scans, leveraging multi-scale feature fusion and a weighted Dice loss to improve accuracy. The method achieves a mean diameter error of 3.3 mm and Dice score of 87%, outperforming 2D approaches and enabling clinically relevant, objective measurement of aneurysm growth and volume for rupture risk assessment.
An abdominal aortic aneurysm (AAA) is a focal dilation of the aorta that, if not treated, tends to grow and may rupture. A significant unmet need in the assessment of AAA disease, for the diagnosis, prognosis and follow-up, is the determination of rupture risk, which is currently based on the manual measurement of the aneurysm diameter in a selected Computed Tomography Angiography (CTA) scan. However, there is a lack of standardization determining the degree and rate of disease progression, due to the lack of robust, automated aneurysm segmentation tools that allow quantitatively analyzing the AAA. In this work, we aim at proposing the first 3D convolutional neural network for the segmentation of aneurysms both from preoperative and postoperative CTA scans. We extensively validate its performance in terms of diameter measurements, to test its applicability in the clinical practice, as well as regarding the relative volume difference, and Dice and Jaccard scores. The proposed method yields a mean diameter measurement error of 3.3 mm, a relative volume difference of 8.58 %, and Dice and Jaccard scores of 87 % and 77 %, respectively. At a clinical level, an aneurysm enlargement of 10 mm is considered relevant, thus, our method is suitable to automatically determine the AAA diameter and opens up the opportunity for more complex aneurysm analysis.
Motivation & Objective
- To address the unmet clinical need for standardized, automated AAA segmentation to improve rupture risk assessment.
- To develop a robust, non-parametric 3D deep learning model that works across preoperative and postoperative CTA scans from diverse vendors.
- To enable accurate, reproducible measurement of aneurysm diameter and volume—key predictors of rupture risk—beyond manual 2D slice-based methods.
- To overcome limitations of intensity-based and shape-constrained segmentation methods that suffer from leakage and high dependency on initial contours.
- To provide a foundation for complex aneurysm geometry analysis, including volume changes and growth rates, crucial for EVAR follow-up.
Proposed method
- The method employs a 3D extension of a hollistically-nested edge detection network, combining feature maps from multiple scale levels to enhance boundary and global shape detection.
- It uses a novel weighted Dice loss function to optimize segmentation, improving performance on imbalanced data with small aneurysm regions.
- The network is trained end-to-end on 80 preoperative and postoperative CTA datasets without requiring prior segmentation of the lumen or centerline.
- It leverages multi-scale features: low-level features for fine edge detection and high-level features for global localization and smooth contour prediction.
- The model is designed to be non-parametric and robust to intensity variations, avoiding reliance on shape priors or manual initialization.
- It processes 3D volumetric CTA data directly, avoiding the need for 2D slice-by-slice processing or intermediate structures like centerlines.
Experimental results
Research questions
- RQ1Can a 3D CNN-based approach outperform 2D methods in segmenting abdominal aortic aneurysms across both preoperative and postoperative CTA scans?
- RQ2To what extent does the proposed 3D CNN reduce diameter measurement error compared to manual assessment, particularly below the 10 mm clinically relevant threshold?
- RQ3How does the model perform in measuring aneurysm volume change, a more sensitive predictor of rupture risk than diameter alone?
- RQ4Can the method achieve robust segmentation without prior segmentation of the lumen or centerline, improving automation and reducing error propagation?
- RQ5Does the use of a weighted Dice loss improve segmentation accuracy on small or thin thrombus regions compared to standard loss functions?
Key findings
- The proposed 3D CNN achieved a mean diameter measurement error of 3.3 mm, which is below the 10 mm threshold considered clinically significant for aneurysm growth.
- The method achieved a Dice similarity coefficient of 87% and a Jaccard score of 77%, indicating high segmentation accuracy.
- The relative volume difference was 8.58%, demonstrating improved accuracy in volume estimation compared to existing methods.
- For 25 out of 28 test cases, the diameter error was below 5 mm, indicating strong consistency across most cases.
- The model outperformed its 2D counterpart and state-of-the-art methods such as graph-cuts and deformable models in both Dice score and volume estimation.
- The approach is robust across different CT scanners and does not require prior segmentation of the lumen or centerline, enhancing clinical applicability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.