This paper presents a method to measure and minimize transverse light-shift in a K-Rb-21Ne atomic spin co-magnetometer by exploiting the relationship between probe light intensity, transverse compensating magnetic field, and steady-state Bloch equations. By optimizing the probe wavelength to 795.68 nm, the transverse light-shift is reduced from -0.115 nT to -0.039 nT, while simultaneously increasing the calibration coefficient to 26.19 V/°/s and reducing the light-shift-related term from 1.113 nT to 0.431 nT.

ABSTRACT

We disclose a method to obtain the transverse light-shift along the probe light of a single-axis alkali metal-noble gas co-magnetometer. The relationship between transverse compensating field and light-shift is deduced through the steady-state solution of Bloch equations. The variety of probe light intensity is used to obtain the residual magnetic field, and step modulation tests are applied to acquire the total spin-relaxation rate of electron spins and self-compensation point. Finally, the transverse light-shift is reduced from -0.115 nT to -0.039 nT by optimizing the probe light wavelength, and the value of the calibration coefficient can be increased simultaneously.

Motivation & Objective

  • To develop a method for measuring transverse light-shift in atomic spin co-magnetometers caused by non-ideal probe light polarization.
  • To address the previously overlooked impact of transverse light-shift on measurement accuracy in single-axis co-magnetometers.
  • To optimize probe light wavelength to minimize light-shift while enhancing the calibration coefficient.
  • To improve the accuracy of rotation rate sensing by suppressing light-shift-induced systematic errors.

Proposed method

  • The method uses the steady-state solution of Bloch equations to relate transverse light-shift (Lx) to residual magnetic field (By) and compensating field (Bcy).
  • Residual magnetic field By is extracted from the intercept of linear fits between Bcy and probe light intensity.
  • Total electron spin-relaxation rate (Rtot) and self-compensation point (Bc) are determined by fitting step modulation signals of By as a function of δBz.
  • The transverse light-shift Lx is calculated using Eq. (6): Lx = (Rtot / γe) * (Bcy + By) / Bc, enabling quantitative correction.
  • Wavelength-dependent light-shift is simulated and experimentally validated, with optimization performed at 795.68 nm.
  • The calibration coefficient is measured and maximized in parallel with light-shift reduction.

Experimental results

Research questions

  • RQ1How can transverse light-shift in a K-Rb-21Ne co-magnetometer be measured under realistic probe beam conditions with elliptical polarization?
  • RQ2What is the quantitative relationship between probe light intensity, transverse compensating field, and residual magnetic field in the presence of light-shift?
  • RQ3How does probe light wavelength affect the magnitude and behavior of transverse light-shift?
  • RQ4Can transverse light-shift be minimized through wavelength optimization without degrading the calibration coefficient?
  • RQ5To what extent can the light-shift-related systematic error be suppressed in a practical co-magnetometer setup?

Key findings

  • The transverse light-shift was reduced from -0.115 nT to -0.039 nT by optimizing the probe light wavelength to 795.68 nm.
  • The light-shift-related term (Rtot / γe) * (Bcy + By) / Bc was reduced from 1.113 nT to 0.431 nT, significantly suppressing systematic error.
  • The calibration coefficient of the co-magnetometer increased to 26.19 V/°/s at the optimal wavelength, indicating improved signal response.
  • The relationship between light-shift and wavelength follows a Lorentzian profile, with minimal effect near 795.6 nm.
  • For wavelengths above 795.68 nm, the light-shift remains nearly constant while the calibration coefficient gradually decreases.
  • The method enables precise measurement and effective suppression of transverse light-shift, enhancing rotation rate sensing accuracy.