TL;DR

This paper proposes a GAN-based fault diagnosis method for imbalanced industrial time series that uses a custom feature extractor and a three-subnetwork encoder-decoder-encoder architecture trained only on normal samples. The model achieves high anomaly detection performance by generating high reconstruction error scores for faulty samples, outperforming BiGANs on both benchmark and real-world bearing datasets.

ABSTRACT

This paper proposes a novel fault diagnosis approach based on generative adversarial networks (GAN) for imbalanced industrial time series where normal samples are much larger than failure cases. We combine a well-designed feature extractor with GAN to help train the whole network. Aimed at obtaining data distribution and hidden pattern in both original distinguishing features and latent space, the encoder-decoder-encoder three-sub-network is employed in GAN, based on Deep Convolution Generative Adversarial Networks (DCGAN) but without Tanh activation layer and only trained on normal samples. In order to verify the validity and feasibility of our approach, we test it on rolling bearing data from Case Western Reserve University and further verify it on data collected from our laboratory. The results show that our proposed approach can achieve excellent performance in detecting faulty by outputting much larger evaluation scores.

Motivation & Objective

  • Address the challenge of imbalanced industrial time series data where normal samples vastly outnumber fault samples.
  • Develop a deep learning framework that can effectively detect rare fault patterns without requiring large labeled fault datasets.
  • Improve fault diagnosis performance by leveraging generative modeling on normal data alone, avoiding bias toward majority class.
  • Validate the method on both public benchmark data (CWRU) and real-world industrial data collected from a laboratory setup.
  • Demonstrate the superiority of the proposed architecture over existing GAN-based methods like BiGAN in anomaly detection for univariate time series.

Proposed method

  • Design a domain-specific feature extractor to extract 16 statistical features (e.g., RMS, kurtosis, skewness) from raw time series, reducing dimensionality and computational cost.
  • Implement a three-subnetwork GAN architecture: encoder-decoder-encoder, based on DCGAN but without Tanh activation, trained exclusively on normal samples.
  • Use the generator to learn the latent distribution of normal time series and reconstruct input samples, while the discriminator distinguishes real from generated samples.
  • Train the entire network using Adam optimizer with initial learning rate 0.001 and betas (0.5, 0.999) for 20 epochs.
  • Detect anomalies by measuring reconstruction error: higher scores indicate greater deviation from normal patterns.
  • Optimize hyperparameters such as subsample length (12,000) and latent vector size (64) to maximize detection accuracy.

Experimental results

Research questions

  • RQ1Can a GAN-based model trained only on normal samples effectively detect faults in imbalanced industrial time series?
  • RQ2How does the proposed feature extractor improve diagnostic performance compared to raw input or generic feature extraction?
  • RQ3What is the optimal configuration of hyperparameters (e.g., subsample length, latent dimension) for robust fault detection?
  • RQ4How does the proposed architecture compare to state-of-the-art GANs like BiGAN in detecting different fault types?
  • RQ5To what extent can the model generalize from benchmark data (CWRU) to real-world industrial data?

Key findings

  • The proposed method achieves excellent fault detection performance on the CWRU rolling bearing dataset, with clear separation between normal and faulty samples based on anomaly scores.
  • On real-world laboratory data, the model maintains high accuracy, demonstrating feasibility in practical industrial settings.
  • The model outperforms BiGAN in both accuracy and stability across varying subsample sizes, indicating architectural superiority.
  • The optimal subsample length of 12,000 (4 minutes at 50Hz) captures the underlying fault patterns in the laboratory dataset.
  • A latent vector size of 64 yields the highest accuracy on the lab dataset, though it has no significant effect on CWRU data.
  • Visualizations confirm that fault samples exhibit significantly higher reconstruction errors and latent space deviations than normal samples, validating the model’s detection mechanism.