Skip to main content
QUICK REVIEW

[Paper Review] A Pragmatic Machine Learning Approach to Quantify Tumor-Infiltrating Lymphocytes in Whole Slide Images

Nikita Shvetsov, Morten Grønnesby|arXiv (Cornell University)|Jun 16, 2022
AI in cancer detectionComputer Science27 references18 citations
TL;DR

This study presents a pragmatic transfer learning approach using the HoVer-Net deep learning model to automatically quantify tumor-infiltrating lymphocytes (TILs) in whole slide images (WSIs) of non-small cell lung cancer (NSCLC) from standard H&E-stained slides, achieving prognostic performance comparable to gold-standard CD8 IHC staining without requiring manual annotation of the target dataset. The method leverages publicly available training data and a cloud-based deployment pipeline for clinical translation.

ABSTRACT

Increased levels of tumor-infiltrating lymphocytes (TILs) indicate favorable outcomes in many types of cancer. The manual quantification of immune cells is inaccurate and time-consuming for pathologists. Our aim is to leverage a computational solution to automatically quantify TILs in standard diagnostic hematoxylin and eosin-stained sections (H&E slides) from lung cancer patients. Our approach is to transfer an open-source machine learning method for the segmentation and classification of nuclei in H&E slides trained on public data to TIL quantification without manual labeling of the data. Our results show that the resulting TIL quantification correlates to the patient prognosis and compares favorably to the current state-of-the-art method for immune cell detection in non-small cell lung cancer (current standard CD8 cells in DAB-stained TMAs HR 0.34, 95% CI 0.17–0.68 vs. TILs in HE WSIs: HoVer-Net PanNuke Aug Model HR 0.30, 95% CI 0.15–0.60 and HoVer-Net MoNuSAC Aug model HR 0.27, 95% CI 0.14–0.53). Our approach bridges the gap between machine learning research, translational clinical research and clinical implementation. However, further validation is warranted before implementation in a clinical setting.

Motivation & Objective

  • To develop a computational method for automatic TIL quantification in H&E-stained whole slide images of NSCLC without manual annotation.
  • To evaluate the transferability of pre-trained deep learning models (HoVer-Net) to a new clinical task using limited labeled data.
  • To compare the prognostic value of TILs identified via deep learning on H&E WSIs to the current standard of CD8 IHC staining.
  • To implement and deploy a cloud-based system for training, inference, and visual inspection of model outputs in a clinical pathology workflow.
  • To assess the impact of data augmentation strategies on model generalization when training on small or limited tissue-type datasets.

Proposed method

  • Fine-tuned the HoVer-Net model, pre-trained on public datasets (ConSep, PanNuke, MoNuSAC), for TIL segmentation and classification in NSCLC H&E WSIs.
  • Applied a novel linear augmentation policy (Balkenhol et al., 2018) to improve model generalization on unseen data, especially with limited training samples.
  • Utilized transfer learning to adapt models trained on diverse histopathology datasets to the specific task of TIL detection in a new, unlabeled NSCLC dataset.
  • Deployed a cloud-based system for model training, inference, and visual inspection, enabling rapid evaluation and clinical deployment.
  • Validated model performance through visual inspection of inference results and survival analysis using Cox proportional hazards models.
  • Integrated MLOps best practices to support iterative experimentation with normalization techniques and augmentation policies.

Experimental results

Research questions

  • RQ1Does transfer learning from public datasets enable accurate TIL quantification in NSCLC H&E WSIs without manual annotation of the target dataset?
  • RQ2How does an additional data augmentation policy affect model performance when training on limited or few tissue types?
  • RQ3Can deep learning-based TIL quantification on H&E WSIs achieve comparable or superior prognostic value to CD8 IHC staining in NSCLC?
  • RQ4How do model performance and generalization vary across different training datasets (ConSep, PanNuke, MoNuSAC) when applied to a new clinical dataset?
  • RQ5To what extent can a cloud-based system support rapid, scalable, and interactive deployment of deep learning models in clinical pathology workflows?

Key findings

  • The HoVer-Net model achieved a hazard ratio (HR) of 0.30 (95% CI 0.15–0.60) for TILs in H&E WSIs, comparable to the current standard CD8 IHC method (HR 0.34, 95% CI 0.17–0.68).
  • Additional data augmentation improved model performance on the CoNSeP dataset, which had fewer training samples, but provided no benefit on larger datasets like PanNuke and MoNuSAC.
  • Models trained on sufficient data and diverse tissue types did not benefit from the additional augmentation policy, suggesting saturation of performance gains.
  • Visual inspection confirmed consistent and reliable TIL segmentation across most images, though performance dropped on images with dark backgrounds or low TIL density, indicating potential overfitting.
  • The cloud-based system enabled rapid deployment and interactive evaluation of models, supporting hypothesis testing and clinical integration.
  • The study demonstrates that state-of-the-art deep learning models can be repurposed for clinical TIL quantification in H&E WSIs with minimal labeling, offering a scalable path to clinical implementation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint