Skip to main content
QUICK REVIEW

[Paper Review] A proposal for experiment with high-intensity tritium neutrino source in Sarov: The search for coherent elastic neutrino-atom scattering and neutrino magnetic moment

M. Cadeddu, Georgy Donchenko|arXiv (Cornell University)|Feb 10, 2023
Neutrino Physics ResearchPhysics and Astronomy3 citations
TL;DR

This paper proposes a high-intensity tritium neutrino source experiment in Sarov, Russia, using a superfluid 4He detector to search for coherent elastic neutrino-atom scattering (CE uAS) and measure the neutrino magnetic moment with unprecedented sensitivity. With tritium source activities of 10–40 MCi, the experiment aims to set a new limit on the neutrino magnetic moment below $10^{-12}\mu_B$ and achieve 5\sigma sensitivity to CE uAS.

ABSTRACT

A description of the current state of the project for the study of coherent elastic neutrino-atom scattering using a tritium source and liquid helium detector is given. The project was proposed in our paper in 2019 and its main goal is to obtain a new record limit on the neutrino magnetic moment at a level below 10^{-12}μ_B using a tritium antineutrino source with an intensity of 10 MCi or even 40 MCi.

Motivation & Objective

  • To observe coherent elastic neutrino-atom scattering (CE uAS) for the first time using a tritium antineutrino source.
  • To set a new, more stringent upper limit on the neutrino magnetic moment than current experiments.
  • To test neutrino electromagnetic properties, including millicharge and charge radius, at an unprecedented sensitivity level.
  • To develop a high-intensity tritium source with 10–40 MCi activity for use in low-background underground conditions.
  • To achieve 5\sigma sensitivity to CE uAS events through optimized detector geometry and low-energy threshold.

Proposed method

  • Use a cylindrical ring assembly of 80 tubular titanium tritide (TiT2) elements to house a tritium source with 10–40 MCi activity.
  • Employ a superfluid 4He target in a cylindrical tank surrounding the tritium source to detect recoiling helium atoms via quantum evaporation.
  • Detect evaporated helium atoms using an array of bolometers on the top surface of the superfluid 4He, sensitive to phonons and rotons from atomic recoil.
  • Utilize the Neganov-Trofimov-Luke effect in a 20-kg silicon detector operating at tens of mK to achieve an energy threshold of ~1–10 eV for elastic neutrino-electron scattering.
  • Model the differential event rate for CE uAS and include contributions from a non-zero neutrino magnetic moment to distinguish signals.
  • Optimize the tritium source design to manage heat from tritium decay, ensuring safe operation and transport via modular, single-element access.
A proposal for experiment with high-intensity tritium neutrino source in Sarov: The search for coherent elastic neutrino-atom scattering and neutrino magnetic moment

Experimental results

Research questions

  • RQ1Can coherent elastic neutrino-atom scattering (CE uAS) be observed for the first time using a tritium antineutrino source?
  • RQ2What is the sensitivity threshold for detecting a non-zero neutrino magnetic moment using this experimental setup?
  • RQ3How does the presence of a neutrino magnetic moment affect the differential event spectrum in CE uAS?
  • RQ4Can the tritium source design achieve sufficient activity (10–40 MCi) while maintaining thermal stability and safety?
  • RQ5What is the expected number of CE uAS events over 5 years of data taking with 10 MCi and 40 MCi sources?

Key findings

  • The experiment expects 58.9 CE uAS events over 5 years with a 10 MCi tritium source and 195.2 events with a 40 MCi source, enabling 5\sigma sensitivity.
  • The sensitivity to the neutrino magnetic moment reaches $3.8 \times 10^{-13}\mu_B$ at 90\% confidence level for a 10 MCi source and $2.3 \times 10^{-13}\mu_B$ for a 40 MCi source.
  • The proposed setup can set a new upper limit on the neutrino magnetic moment below $10^{-12}\mu_B$, improving on current limits by two orders of magnitude.
  • The tritium source design with 80 tubular TiT2 elements allows for modular handling, effective heat dissipation, and compliance with international safety standards.
  • The superfluid 4He detector enables detection of atomic recoils via quantum evaporation, with bolometers measuring the number of evaporated atoms with high sensitivity.
  • The use of a low-threshold Si detector (1–10 eV) in conjunction with the tritium source is expected to further enhance sensitivity to neutrino electromagnetic properties.
A proposal for experiment with high-intensity tritium neutrino source in Sarov: The search for coherent elastic neutrino-atom scattering and neutrino magnetic moment

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.