[Paper Review] JUNO Conceptual Design Report
The JUNO Conceptual Design Report proposes a 20,000-ton underground liquid scintillator detector in China to determine the neutrino mass hierarchy by measuring reactor antineutrinos from two nearby nuclear power plants. With 17,000 high-quantum-efficiency photomultiplier tubes and a 35-meter acrylic sphere, the detector achieves 3% energy resolution at 1 MeV and can resolve the mass hierarchy at 3–4σ confidence within six years of operation.
Plenary talk presented at the XXI International Workshop on Neutrino Telescopes - Padova 29 September - 3 October 2025 (https://agenda.infn.it/event/44606/) On behalf of the JUNO Collaboration
Motivation & Objective
- To determine the neutrino mass hierarchy using reactor antineutrinos from two nuclear power plants located 53 km away.
- To measure neutrino oscillation parameters sin²θ₁₂, Δm²₂₁, and |Δm²ₑₑ| with sub-1% accuracy.
- To develop a large-scale, high-precision liquid scintillator detector capable of studying terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model.
- To achieve optimal background suppression through a dual-veto system and full-volume calibration.
- To ensure stable, efficient data acquisition via a robust readout, control, and offline system.
Proposed method
- Deploy a 20,000-ton liquid scintillator detector in an underground hall beneath 700 m of granite overburden.
- Use a 35-meter diameter acrylic sphere to contain the scintillator and house 17,000 508-mm photomultiplier tubes with ~75% optical coverage.
- Employ linear alkyl benzene (LAB) as the solvent with PPO and Bis-MSB as the scintillator and wavelength shifter, respectively.
- Achieve >1,100 photoelectrons per MeV and 3% energy resolution at 1 MeV, enabling high-precision energy measurement.
- Implement a comprehensive calibration system using multiple radioactive sources to cover the full energy range and ensure full-volume position sensitivity.
- Integrate a Water Cherenkov detector and Top Tracker system to detect muons and suppress muon-induced backgrounds.
Experimental results
Research questions
- RQ1Can the JUNO detector resolve the neutrino mass hierarchy with a significance of 3–4σ within six years of operation?
- RQ2What level of precision can be achieved in measuring the neutrino oscillation parameters sin²θ₁₂, Δm²₂₁, and |Δm²ₑₑ|?
- RQ3Can the detector achieve 3% energy resolution at 1 MeV using liquid scintillator with high photoelectron yield?
- RQ4How effectively can the calibration system ensure uniform energy response and position reconstruction across the entire detector volume?
- RQ5To what extent can the veto system reduce muon-induced backgrounds in the detector?
Key findings
- The JUNO detector can resolve the neutrino mass hierarchy at a 3–4σ confidence level within six years of data-taking.
- The energy resolution is expected to be 3% at 1 MeV, with more than 1,100 photoelectrons detected per MeV.
- Neutrino oscillation parameters sin²θ₁₂, Δm²₂₁, and |Δm²ₑₑ| can be determined with an accuracy better than 1%.
- The detector achieves ~75% optical coverage using 17,000 high-quantum-efficiency photomultiplier tubes.
- The calibration system is designed to provide full-volume position coverage and energy response uniformity using multiple radioactive sources.
- The veto system, comprising a Water Cherenkov detector and Top Tracker, enables effective muon detection and background suppression.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.