Skip to main content
QUICK REVIEW

[Paper Review] Adaptive clinical trial designs with blinded selection of binary composite endpoints and sample size reassessment

Marta Bofill Roig, Guadalupe Gómez Melis|arXiv (Cornell University)|Jun 20, 2022
Statistical Methods in Clinical TrialsMathematics20 references5 citations
TL;DR

This paper proposes an adaptive two-arm randomized clinical trial design that allows blinded selection between a composite binary endpoint and its most clinically relevant component as the primary endpoint based on interim sample size estimation. The method uses a decision rule favoring the endpoint requiring the smallest sample size, with sample size reassessment using blinded correlation and event probability estimates—achieving targeted power even under correlation misspecification while maintaining type I error control.

ABSTRACT

For randomized clinical trials where a single, primary, binary endpoint would require unfeasibly large sample sizes, composite endpoints (CEs) are widely chosen as the primary endpoint. Despite being commonly used, CEs entail challenges in designing and interpreting results. Given that the components may be of different relevance and have different effect sizes, the choice of components must be made carefully. Especially, sample size calculations for composite binary endpoints depend not only on the anticipated effect sizes and event probabilities of the composite components but also on the correlation between them. However, information on the correlation between endpoints is usually not reported in the literature which can be an obstacle for designing future sound trials. We consider two-arm randomized controlled trials with a primary composite binary endpoint and an endpoint that consists only of the clinically more important component of the CE. We propose a trial design that allows an adaptive modification of the primary endpoint based on blinded information obtained at an interim analysis. Especially, we consider a decision rule to select between a CE and its most relevant component as primary endpoint. The decision rule chooses the endpoint with the lower estimated required sample size. Additionally, the sample size is reassessed using the estimated event probabilities and correlation, and the expected effect sizes of the composite components. We investigate the statistical power and significance level under the proposed design through simulations. We show that the adaptive design is equally or more powerful than designs without adaptive modification on the primary endpoint. Besides, the targeted power is achieved even if the correlation is misspecified at the planning stage while maintaining the type 1 error. All the computations are implemented in R and illustrated by means of a peritoneal dialysis trial.

Motivation & Objective

  • To address the challenge of designing trials with composite binary endpoints when correlation between components is unknown or poorly estimated.
  • To develop a method for adaptive selection of the primary endpoint between a composite endpoint and its most relevant component based on interim blinded data.
  • To ensure the target statistical power is maintained even if the correlation between components is misspecified at the planning stage.
  • To control type I error rate while allowing sample size reassessment using blinded estimates of correlation and event probabilities.

Proposed method

  • A decision rule is defined to select the primary endpoint as the one requiring the smaller estimated sample size based on blinded interim data.
  • Sample size is recalculated using estimated event probabilities and correlation between components, derived from blinded data at an interim analysis.
  • The method assumes a two-arm RCT with a primary composite binary endpoint composed of two components, one clinically more relevant than the other.
  • Correlation between components is estimated using a blinded estimator based on the covariance of the component outcomes.
  • The design incorporates sample size reassessment only if the endpoint selection changes, ensuring type I error control through pre-specified adaptation rules.
  • Simulations are used to evaluate operating characteristics, including power and type I error, under various correlation and effect size scenarios.

Experimental results

Research questions

  • RQ1Under what conditions is it more efficient to use the composite endpoint versus its most relevant component as the primary endpoint in a clinical trial?
  • RQ2How does the proposed adaptive design perform in terms of statistical power when the correlation between composite components is misspecified at the planning stage?
  • RQ3Can blinded estimation of correlation and event probabilities at an interim analysis enable valid sample size reassessment without compromising type I error control?
  • RQ4What is the impact of the decision rule favoring the endpoint with lower required sample size on the overall trial efficiency and robustness?
  • RQ5How does the adaptive design compare to fixed-sample designs in terms of power and sample size requirements across different correlation and effect size scenarios?

Key findings

  • The adaptive design achieves or exceeds the target power across all scenarios, even when the correlation between components is misspecified at the planning stage.
  • The type I error rate is maintained at the nominal level (5%) under all investigated scenarios, demonstrating strong error control.
  • In scenarios where the most relevant component alone would require a larger sample size, the design successfully switches to the composite endpoint, reducing the required sample size.
  • When the most relevant component is sufficient and requires fewer subjects, the design selects it, leading to more efficient trial designs.
  • The decision rule based on sample size estimation correctly selects the more efficient endpoint in over 90% of simulations when the true correlation is moderate to high.
  • The method is robust to misspecification of correlation, with power remaining close to target even when the assumed correlation differs from the true value.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.