Skip to main content
QUICK REVIEW

[Paper Review] An improved method to measure microwave induced impulsive forces with a torsion balance or weighing scale

Chris P. Duif|arXiv (Cornell University)|Jan 1, 2017
Mechanical and Optical ResonatorsPhysics and Astronomy2 references2 citations
TL;DR

This paper presents a novel contactless microwave power delivery method using a tunable coupling cavity to supply microwave energy to a device under test (e.g., an EmDrive) without direct electrical connections. By decoupling the microwave source from the force measurement system (torsion balance or scale), the method reduces thermal and electromagnetic disturbances, achieving >75% power transmission (−1.3 dB loss) and negligible disturbing forces (<10−5 N) at up to 15 W, significantly improving measurement accuracy for anomalous thrust experiments.

ABSTRACT

A novel method is presented for measuring impulsive forces generated by devices which are fed with medium power microwave signals. The forces are measured with a torsion balance or weighing scale, as usual, but the microwave signal is coupled directly to the device under test via a special coupling cavity instead of being generated on the measurement device. The method was verified at power levels up to 15 W, has a transmission of at least 75% (-1.3 dB attenuation) and is shown not to exert disturbing forces at this power level (vertical forces smaller then 10 micronewton). The application of this way of supplying microwave signals could significantly improve experiments which otherwise suffer from heat dissipation and Lorentz forces by components present on the force measurement device. A particular field of application, where previous research has failed to prove or disprove the existence of certain anomalous forces, is discussed.

Motivation & Objective

  • To address experimental uncertainties in measuring microwave-induced impulsive forces, particularly in EmDrive-type experiments.
  • To eliminate heat dissipation and Lorentz forces caused by onboard microwave components and DC currents on the force measurement device.
  • To develop a method that allows precise, contactless microwave power delivery to the device under test while maintaining high measurement sensitivity.
  • To enable more reliable and repeatable experiments on anomalous thrust devices by minimizing external interference sources.

Proposed method

  • A specially designed coupling cavity acts as a tunable microwave bandwidth filter with a non-contacting movable endplate to transfer microwave power without physical connection.
  • Microwave power is generated externally and coupled into the test cavity via magnetic coupling through the non-contacting endplate.
  • Forward and reflected power are monitored using a directional coupler and battery-powered optical-readout power sensors to avoid electrical interference.
  • The system uses a water-cooled mantle to manage heat dissipation from the coupling cavity walls if needed.
  • The coupling cavity is designed to minimize electromagnetic radiation and external interference, with microwave-absorbing materials used to suppress stray radiation.
  • The method allows for precise control of frequency and power without requiring wireless control systems or magnetic components on the measurement device.

Experimental results

Research questions

  • RQ1Can microwave power be delivered to a force-measuring device without direct electrical connections, thereby reducing thermal and electromagnetic disturbances?
  • RQ2Does the coupling cavity introduce measurable disturbing forces on the torsion balance or weighing scale at power levels up to 15 W?
  • RQ3Can the method achieve high power transfer efficiency (>75%) while minimizing heat generation and Lorentz forces on the measurement platform?
  • RQ4To what extent does the contactless coupling method improve the reliability and accuracy of anomalous thrust measurements in resonant microwave cavities?
  • RQ5Can this method be applied to test the validity of the EmDrive's claimed net thrust without violating conservation of momentum?

Key findings

  • The coupling cavity achieved a power transmission efficiency of ≥75% (−1.3 dB loss), with potential for further improvement by ~0.5 dB through optimization of coupling loops.
  • Disturbing electromagnetic forces on the measurement device were found to be negligible, less than 10−5 N at 15 W input power.
  • Heat dissipation on the force measurement device was reduced by one to two orders of magnitude compared to conventional setups with onboard microwave amplifiers.
  • The method successfully decoupled the microwave source from the measurement system, eliminating DC current-induced Lorentz forces and reducing the mass of the measurement platform by several kilograms.
  • No significant electromagnetic interference was observed on the balance electronics, despite microwave leakage, indicating robustness in practical use.
  • The system demonstrated stable operation across a range of frequencies and power levels, with potential for use up to several hundred watts and in the 100 MHz to 20 GHz range.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.