[Paper Review] ANAIS: Status and prospects
ANAIS aims to confirm the DAMA/LIBRA dark matter annual modulation signal using 250 kg of ultra-pure NaI(Tl) scintillators at the Canfranc Underground Laboratory. With a 1 keVee energy threshold and improved light collection (12–16 phe/keV), the experiment achieves high sensitivity to low-mass WIMPs, even under conservative background scenarios, validating its potential to confirm or rule out the DAMA signal model-independently.
ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA positive signal in a model-independent way. The detector will consist in an array of close-packed single modules, each of them coupled to two high efficiency Hamamatsu photomultipliers. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. These modules have shown an outstanding light collection efficiency (12-16 phe/keV), about the double of that from DAMA/LIBRA phase 1 detectors, which could enable reducing the energy threshold down to 1 keVee. ANAIS crystal radiopurity goals are fulfilled for 232Th and 238U chains, assuming equilibrium, and in the case of 40K, present crystals activity (although not at the required 20 ppb level) could be acceptable. However, a 210Pb contamination out-of-equilibrium has been identified and its origin traced back, so we expect it will be avoided in next prototypes. Finally, current status and prospects of the experiment considering several exposure and background scenarios are presented.
Motivation & Objective
- Confirm the DAMA/LIBRA annual modulation signal in a model-independent way using the same target and detection technique.
- Achieve an energy threshold ≤ 1 keVee to probe low-mass WIMPs.
- Minimize radioactive backgrounds, particularly from 210Pb and 40K, to ensure sensitivity at low energies.
- Demonstrate that ultra-pure NaI(Tl) scintillators with high light collection can enable background suppression and threshold reduction.
- Project sensitivity across multiple background and exposure scenarios to assess experimental viability.
Proposed method
- Deploy two 12.5 kg NaI(Tl) crystals from Alpha Spectra in a closed-packed array with dual Hamamatsu PMTs and quartz windows to maximize light collection.
- Use active veto systems and lead shielding with anti-radon boxes to suppress external and cosmogenic backgrounds.
- Implement a low-energy calibration system using 57Co and 109Cd sources via Mylar windows for precise energy response characterization.
- Apply coincidence analysis and multiple-hit event rejection to suppress 40K and 210Pb backgrounds, especially at low energies.
- Model sensitivity using Helm form factors, standard halo model parameters, and quenching factors for Na and I.
- Simulate projected sensitivity across three background scenarios: baseline (reduced 210Pb), ANAIS-25 background levels, and a conservative model including all known sources.
Experimental results
Research questions
- RQ1Can ANAIS achieve a 1 keVee energy threshold with its current detector configuration?
- RQ2To what extent can 40K and 210Pb backgrounds be suppressed using event selection and detector geometry?
- RQ3What is the projected sensitivity of ANAIS to spin-independent WIMP scattering across different background models?
- RQ4Does the improved light collection (12–16 phe/keV) significantly enhance energy resolution and threshold performance compared to DAMA/LIBRA?
- RQ5Can the 210Pb contamination be eliminated in future prototypes, and how would that affect low-energy sensitivity?
Key findings
- The ANAIS-25 prototype achieved a light collection efficiency of 16.13 ± 0.66 phe/keV with high-quantum-efficiency PMTs, significantly improving signal detection at low energies.
- Energy resolution of 11.3 keV FWHM at 122.1 keV and 2.8 keV at 5.9 keV was achieved, indicating excellent energy resolution.
- A 0.9 keV peak from 22Na decay was clearly observed in coincidence, suggesting a 1 keVee threshold is achievable with high efficiency.
- The 210Pb contamination was identified as the dominant source of background below 20 keV, with an out-of-equilibrium origin traced to the crystal production process.
- Despite 40K levels at 41 ppb (above the 20 ppb goal), background from this source can be reduced below 2 c/keVee/kg/day via multiple-hit rejection in the closed-packed configuration.
- Projected sensitivity in the most conservative background scenario still achieves good sensitivity in the parameter space of the DAMA/LIBRA positive signal, especially with a 1 keVee threshold.