Skip to main content
QUICK REVIEW

[Paper Review] Analyzing Eight Years of Transiting Exoplanet Observations Using WFC3's Spatial Scan Monitor

Kevin B. Stevenson, J. Fowler|arXiv (Cornell University)|Oct 3, 2019
Stellar, planetary, and galactic studiesPhysics and Astronomy6 citations
TL;DR

This paper analyzes eight years of Hubble Space Telescope WFC3 spatial scan observations of transiting exoplanets, using an automated pipeline to assess data quality and pointing stability. It finds that 77.1% of observations achieve optimal precision, with a key recommendation to use the ROUND_TRIP scan mode for improved signal-to-noise and reduced overheads, while also refining fluence-based exposure time models for better precision in both bright and faint targets.

ABSTRACT

HST/WFC3's spatial scan monitor automatically reduces and analyzes time-series data taken in spatial scan mode with the IR grisms. Here we describe the spatial scan monitor pipeline and present results derived from eight years of transiting exoplanet data. Our goal is to monitor the quality of the data and make recommendations to users that will enhance future observations. We find that a typical observation achieves a white light curve precision that is $1.07\ imes$ the photon-limit (which is slightly better than expectations) and that the pointing drift is relatively stable during times of normal telescope operations. We note that observations cannot achieve the optimal precision when the drift along the dispersion direction ($X$ axis) exceeds 15 mas ($\\sim$0.11 pixels). Based on our sample, 77.1% of observations are ''successful'' ($<15$ mas rms drift), 12.0% are ''marginal'' (15 -- 135 mas), and 10.8% of observations have ''failed'' ($>135$ mas or $>1$ pixel), meaning they do not achieve the necessary pointing stability to achieve the optimal spectroscopic precision. In comparing the observed versus calculated maximum pixel fluence, we find that the J band is a better predictor of fluence than the H band. Using this information, we derive an updated, empirical relation for scan rate that also accounts for the J-H color of the host star. We implement this relation and other improvements in version 1.4 of PandExo and version 0.5 of ExoCTK. Finally, we make recommendations on how to plan future observations with increased precision.

Motivation & Objective

  • To evaluate the long-term performance and data quality of WFC3's spatial scan mode in time-series exoplanet observations.
  • To identify factors limiting spectroscopic light curve precision, particularly pointing drift and pixel fluence.
  • To improve observational efficiency by recommending optimal observing strategies, including scan mode and exposure time.
  • To refine empirical models for exposure time and scan rate based on stellar J-H color and fluence.
  • To update calibration tools like PandExo and ExoCTK with improved, empirically derived observing strategies.

Proposed method

  • Automated data reduction pipeline processes WFC3/IR grism spatial scan data using non-destructive readout differencing and background subtraction.
  • Applies double outlier rejection along time and spatial axes to remove noise and systematics.
  • Performs sub-pixel pointing drift correction using a two-step drift estimation and correction process.
  • Uses optimal spectral extraction (Horne, 1986) and the Divide White method to compute wavelength-independent light curves.
  • Employs the WFC3 Quicklook database and pyql package to identify spatial scan data via SCAN_TYP header keywords.
  • Derives an updated empirical scan rate relation that accounts for J-H color and maximum pixel fluence, improving exposure time predictions.

Experimental results

Research questions

  • RQ1What is the typical spectroscopic light curve precision achieved in WFC3 spatial scan observations over eight years?
  • RQ2How does pointing drift along the dispersion axis affect data quality and achievable precision?
  • RQ3Which stellar magnitude and color regime benefits most from longer exposure times or higher fluence?
  • RQ4How does the ROUND_TRIP scan mode compare to FORWARD mode in terms of precision and overhead efficiency?
  • RQ5Can fluence in the J band better predict pixel saturation than H band, and how can this improve exposure time modeling?

Key findings

  • A typical observation achieves a white light curve precision of 1.07× the photon limit, slightly better than expected.
  • 77.1% of observations are classified as 'successful' with <15 mas rms pointing drift, while 10.8% are 'failed' due to drift >135 mas.
  • The ROUND_TRIP spatial scan mode yields a median precision improvement of 6.4 ppm per spectroscopic channel over FORWARD mode, due to reduced overheads.
  • J-band fluence is a better predictor of pixel fluence than H-band, leading to an updated empirical scan rate model that includes J-H color.
  • For bright targets (J < 8), increasing maximum pixel fluence beyond 30k e−/pix improves precision; for faint targets (J > 8), longer exposures (>150 s) enhance signal-to-noise.
  • Measured precision is typically within 50 ppm of PandExo_HST predictions, with a potential systematic noise floor of ≤21 ppm for R ~ 40.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.