[Paper Review] Anatomically constrained CT image translation for heterogeneous blood vessel segmentation
This paper proposes an anatomically constrained CycleGAN for unpaired CT image translation between contrast-enhanced (ceCT) and non-contrast (CT) CT scans, improving structural consistency and segmentation performance. By integrating self-supervised body regression and region-of-interest selection, the method generates high-fidelity, anatomically plausible images, achieving blood vessel segmentation accuracy comparable to real CT scans.
Anatomical structures such as blood vessels in contrast-enhanced CT (ceCT) images can be challenging to segment due to the variability in contrast medium diffusion. The combined use of ceCT and contrast-free (CT) CT images can improve the segmentation performances, but at the cost of a double radiation exposure. To limit the radiation dose, generative models could be used to synthesize one modality, instead of acquiring it. The CycleGAN approach has recently attracted particular attention because it alleviates the need for paired data that are difficult to obtain. Despite the great performances demonstrated in the literature, limitations still remain when dealing with 3D volumes generated slice by slice from unpaired datasets with different fields of view. We present an extension of CycleGAN to generate high fidelity images, with good structural consistency, in this context. We leverage anatomical constraints and automatic region of interest selection by adapting the Self-Supervised Body Regressor. These constraints enforce anatomical consistency and allow feeding anatomically-paired input images to the algorithm. Results show qualitative and quantitative improvements, compared to stateof-the-art methods, on the translation task between ceCT and CT images (and vice versa).
Motivation & Objective
- To address the challenge of heterogeneous contrast in ceCT images, which hinders accurate blood vessel segmentation.
- To reduce radiation exposure by synthesizing one CT modality (ceCT or CT) using generative models instead of acquiring both.
- To improve 3D image translation fidelity and anatomical consistency in unpaired, slice-wise 3D volume translation.
- To enable high-quality, anatomically consistent CT image synthesis without paired training data.
- To validate that synthesized CT images can support segmentation performance equivalent to real CT scans.
Proposed method
- Adapts CycleGAN with a self-supervised body regressor (SSBR) to automatically identify anatomically relevant regions, particularly the renal region, for slice alignment.
- Introduces a position-based selection (PBS) strategy to select corresponding slices across ceCT and CT volumes based on anatomical landmarks.
- Applies 3D affine registration using SimpleITK to align volumes before applying the image translation model.
- Uses U-Net as the generator and Patch-GAN as the discriminator, with cycle consistency and adversarial losses.
- Incorporates anatomical constraints by ensuring that generated slices correspond to the same anatomical content as input slices.
- Employs a multi-stage training pipeline: 3D registration, PBS/SSBR-based slice selection, and CycleGAN-based image translation.
Experimental results
Research questions
- RQ1Can anatomical constraints improve the fidelity and consistency of 3D CT image translation in the absence of paired data?
- RQ2Does slice selection based on anatomical landmarks (e.g., kidneys) enhance structural alignment and translation quality in unpaired CT image translation?
- RQ3Can the synthesized CT images achieve segmentation performance comparable to real CT images for heterogeneous blood vessels?
- RQ4How does the proposed method compare to state-of-the-art unpaired image translation models (e.g., standard CycleGAN, UNIT) in terms of visual and quantitative quality?
- RQ5To what extent does anatomical consistency in generated images reduce artifacts and improve downstream segmentation tasks?
Key findings
- The proposed method achieved a Dice score of 70.01 ± 3.99 for arteries and 56.55 ± 20.20 for veins on real ceCT using synthesized CT images, matching the performance of real CT scans.
- Segmentation using the proposed method’s synthesized CT images outperformed both standard CycleGAN and UNIT baselines, with a 4.45% absolute improvement in Dice score for arteries compared to PBS-based CycleGAN.
- The use of SSBR and PBS-based slice selection significantly reduced anatomical misalignment and improved structural consistency in generated images.
- The method reduced HD95 (Hausdorff distance) to 13.47 ± 10.09 mm for arteries and 20.93 ± 22.96 mm for veins, indicating better segmentation boundary accuracy.
- On a highly heterogeneous patient, the method achieved a Dice score of 70.15 ± 3.52 for arteries and 37.00 ± 16.11 for veins using synthesized CT, outperforming real ceCT-only segmentation.
- Visual comparisons confirmed reduced artifacts and improved anatomical plausibility in generated images compared to baseline models.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.