[Paper Review] Antimatter gravity with muonium
This paper proposes a direct measurement of antimatter's gravitational acceleration using a slow, monoenergetic muonium beam directed at a precision three-grating atom interferometer. The experiment aims to measure the gravitational deflection of muonium to 10% precision in months of beam time at PSI, potentially enabling the first direct test of gravity on leptonic and second-generation matter, and possibly the first measurement of antimatter's gravitational acceleration overall.
The gravitational acceleration of antimatter, $\bar{g}$, has never been directly measured and could bear importantly on our understanding of gravity, the possible existence of a fifth force, and the nature and early history of the universe. Three avenues appear feasible for such a measurement: antihydrogen, positronium, and muonium. The muonium measurement requires a novel monoenergetic, low-velocity, horizontal muonium beam directed at an atom interferometer. The precision three-grating interferometer can be produced in silicon nitride or ultrananocrystalline diamond using state-of-the-art nanofabrication. The required precision alignment and calibration at the picometer level also appear to be feasible. With 100 nm grating pitch, a 10% measurement of $\bar{g}$ can be made using some months of surface-muon beam time, and a 1% or better measurement with a correspondingly larger exposure. This could constitute the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.
Motivation & Objective
- To directly measure the gravitational acceleration of antimatter, specifically muonium, which has not been done experimentally.
- To test whether antimatter falls at the same rate as matter, probing violations of the equivalence principle and potential new physics.
- To provide the first direct measurement of gravity's effect on second-generation matter and leptonic antimatter.
- To complement ongoing antihydrogen and positronium gravity experiments with a new, feasible approach.
- To develop a precision interferometer capable of picometer-level alignment and calibration for atomic-scale gravity measurements.
Proposed method
- Use a low-velocity, horizontal muonium beam produced at the Paul Scherrer Institute (PSI) using surface muons.
- Direct the muonium beam through a precision three-grating atom interferometer fabricated in silicon nitride or ultrananocrystalline diamond (UNCD).
- Employ piezoelectric actuators to vertically displace the third grating and measure interference fringes as a function of displacement.
- Use soft x-rays from a synchrotron or bench-top source to calibrate the interferometer’s absolute phase and track drifts in real time.
- Utilize time-resolved interferometry (TFG) to monitor short-term stability and cross-validate with x-ray phase measurements.
- Apply finite element analysis (FEA) to model grating stability and optimize design with buttresses and flexural hinges for mechanical robustness.
Experimental results
Research questions
- RQ1Can the gravitational acceleration of muonium, a bound state of a positive muon and an electron, be measured directly with atomic interferometry?
- RQ2Does antimatter, specifically muonium, experience the same gravitational acceleration as matter, as predicted by general relativity?
- RQ3Can a precision three-grating interferometer achieve the required picometer-level stability and alignment for measuring gravitational phase shifts in muonium?
- RQ4Is the use of soft x-rays for real-time phase calibration effective in maintaining long-term interferometer stability?
- RQ5Can the required muonium beam be produced with sufficient intensity and low velocity for a measurable signal within feasible beam time?
Key findings
- A 10% measurement of the gravitational acceleration of muonium ($\bar{g}$) is achievable with approximately 100 nm grating pitch and several months of beam time at PSI.
- A 1% or better precision measurement of $\bar{g}$ is feasible with increased beam exposure, higher intensity, or improved detection efficiency.
- The interferometer design, using silicon nitride or ultrananocrystalline diamond (UNCD) membranes with 50-nm-wide slits, is feasible using e-beam lithography and reactive ion etching (RIE).
- Prototype grating fabrication has been approved at Argonne National Laboratory's Center for Nanoscale Materials (CNM), with test exposures already demonstrating feasibility.
- The combination of time-resolved interferometry (TFG) and x-ray phase monitoring enables real-time tracking of system drifts, ensuring long-term stability.
- The use of flexural hinges and buttressed grating structures is expected to maintain mechanical stability under thermal and vibrational loads.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.