Skip to main content
QUICK REVIEW

[Paper Review] Assessing the Value of Complex Refractive Index and Particle Density for Calibration of Low-Cost Particle Matter Sensor for Size-Resolved Particle Count and PM2.5 Measurements

Ching-Hsuan Huang, Jiayang He|arXiv (Cornell University)|Jun 6, 2021
Air Quality Monitoring and ForecastingEnvironmental Science50 references18 citations
TL;DR

This study develops and evaluates calibration models for the Plantower PMS A003 low-cost PM sensor using controlled aerosol tests with standardized polydisperse particles. It demonstrates that linear calibration without adjusting for particle properties achieves <4.0% normalized mean absolute error (NMAE) for number concentration, while models incorporating complex refractive index (CRI), density, and non-linearity significantly reduce error for mass concentration (PM2.5, PM10), especially in high-concentration environments like wildfire smoke or industrial settings.

ABSTRACT

Commercially available low-cost particulate matter (PM) sensors provide output as total or size-specific particle counts and mass concentrations. These quantities are not measured directly but are estimated by the original equipment manufacturers' (OEM) proprietary algorithms and have inherent limitations since particle scattering depends on their composition, size, shape, and complex index of refraction (CRI). Hence, there is a need to characterize and calibrate their performance under a controlled environment. We present calibration algorithms for Plantower PMS A003 sensor as a function of particle size and concentration. A standardized experimental protocol was used to control the PM level, environmental conditions and to evaluate sensor-to-sensor reproducibility. The calibration was based on tests when PMS A003 were exposed to different polydisperse standardized testing aerosols. The results suggested particle size distribution from PMS A003 was shifted compared to reference instrument measures. For calibration of number concentration, linear model without adjusting aerosol properties corrects the raw PMS A003 measurement for specific size bins with normalized mean absolute error within 4.0% of the reference instrument. Although the Bayesian Information Criterion suggests that models adjusting for particle optical properties and relative humidity are technically superior, they should be used with caution as the particle properties used in fitting were within a narrow range for challenge aerosols. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM's mass concentrations estimates and demonstrated lower error. These results have significant implications for using PMS A003 in high concentration environments, including indoor air quality and occupational/industrial exposure assessments, wildfire smoke, or near-source monitoring scenarios.

Motivation & Objective

  • To address the lack of reliable calibration for low-cost PM sensors in measuring size-resolved particle number and mass concentrations.
  • To evaluate the impact of particle optical properties—specifically complex refractive index (CRI) and density—on sensor accuracy.
  • To develop and validate calibration models that improve sensor performance across varying particle concentrations and environmental conditions.
  • To assess the necessity of accounting for non-linear responses in OEM-estimated mass concentrations, especially at high PM levels.
  • To provide a standardized protocol for sensor calibration applicable to indoor, occupational, and near-source monitoring scenarios.

Proposed method

  • Conducted controlled laboratory experiments using an aerosol chamber with four standardized polydisperse test aerosols (ATD, PSL, NaCl, and S02) across a range of concentrations (0–1000 #/cm³).
  • Measured reference particle number and mass concentrations using a TSI Aerodynamic Particle Sizer (APS) as the gold standard.
  • Applied linear, polynomial, and hybrid models incorporating CRI, particle density, and relative humidity (RH) to correct OEM sensor outputs.
  • Used Bayesian Information Criterion (BIC) to compare model fit and select optimal models, while also calculating normalized mean absolute error (NMAE) for validation.
  • Evaluated sensor-to-sensor reproducibility and performance across full and low concentration ranges (0–1000 #/cm³ and <100 #/cm³).
  • Generated calibration equations for PM1, PM2.5, and PM10 using regression analysis, with separate models for number and mass concentrations.

Experimental results

Research questions

  • RQ1How does the PMS A003 sensor’s raw output for particle number and mass concentration compare to reference measurements across varying particle sizes and concentrations?
  • RQ2To what extent do particle properties such as complex refractive index (CRI) and density affect the accuracy of low-cost PM sensor measurements?
  • RQ3Can calibration models that include CRI, density, and RH improve the accuracy of mass concentration estimates beyond simple linear corrections?
  • RQ4How does sensor performance vary between high and low concentration environments, particularly in scenarios relevant to wildfire smoke or indoor pollution?
  • RQ5Which calibration model structure (linear, polynomial, or hybrid with physical parameters) offers the best balance of accuracy and reliability for real-world deployment?

Key findings

  • The PMS A003 sensor’s raw number concentration measurements were consistently underestimated compared to the APS reference, with a shift in size distribution.
  • A simple linear calibration model without adjusting for CRI or RH achieved a normalized mean absolute error (NMAE) of 3.11% for PM1 and 4.53% for PM2.5, with NMAE <4.0% for number concentration across all size bins.
  • Models incorporating CRI and particle density reduced NMAE for PM2.5 from 4.53% (linear) to 2.33% (polynomial + CRI + density), demonstrating significant improvement in mass concentration accuracy.
  • The Bayesian Information Criterion (BIC) favored models that included CRI, density, and RH, indicating better statistical fit, though these models were based on a narrow range of aerosol types.
  • Non-linear responses in OEM mass concentration estimates were observed, especially at high concentrations, and were best corrected by polynomial models with physical parameters.
  • The calibration models for PM2.5 and PM10 that included CRI, density, and non-linearity showed the lowest NMAE (2.33% and 2.61%, respectively), confirming the necessity of such adjustments in high-concentration environments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.