Skip to main content
QUICK REVIEW

[Paper Review] Particle Dynamics in Corona Induced Electro-hydrodynamic Flow

Ravi Sankar Vaddi, Yifei Guan|arXiv (Cornell University)|Feb 8, 2019
Aerosol Filtration and Electrostatic PrecipitationEngineering4 references6 citations
TL;DR

This study investigates particle dynamics in corona-induced electro-hydrodynamic (EHD) flow using a point-to-tube electrode configuration. A coupled multiphysics model solving ion transport and Navier-Stokes equations predicts electric field, charge density, and flow fields, showing axial maximum EHD velocities of 1–4 m/s. Key findings reveal enhanced collection efficiency for 10–20 nm particles due to high charging efficiency in intense fields, with peak efficiency near 20 nm and a drop for smaller particles due to reduced mobility.

ABSTRACT

Particle behavior in electro-hydrodynamic (EHD) flow induced by corona discharge is investigated. EHD flow in a point-to-tube corona configuration is studied experimentally and numerically. Multiphysics numerical model couples ion transport equation and the Navier-Stokes equations (NSE) to solve for the spatiotemporal distribution of electric field, charge density, and flow field; the results are compared with experimental velocity profiles at the exit. The velocity and the flow rate increase with corona voltage, the maximum velocity of EHD flow is located at the axis and ranges from ~1-4 m/s. Collection efficiency trends for 20-150 nm nanoparticle on the ground electrode for ambient and NaCl particles are in good agreement with the theoretical models. However, for particles in 10-20 nm size range, the measured collection efficiency increases for smaller particles due to increase particle charging efficiency in the high-intensity electric field and high charge density environment of the EHD driven flow. These conditions allow a greater number of particles below 20 nm to acquire and hold a single charge, for particles approaching 20 nm the collection efficiency reduces due to their increase in mass, thus lower electrical mobility. For particles larger than 20 nm, the electrical mobility and the collection increases as they acquire multiple charges on a single particle.

Motivation & Objective

  • To understand the behavior of nanoparticles in electro-hydrodynamic (EHD) flows generated by corona discharge.
  • To quantify the influence of corona voltage on EHD flow velocity and flow rate in a point-to-tube geometry.
  • To analyze particle collection efficiency on a ground electrode for ambient and NaCl nanoparticles across 20–150 nm.
  • To investigate the anomalous increase in collection efficiency for 10–20 nm particles due to enhanced charging in high-intensity electric fields.
  • To explain the reduction in collection efficiency for particles near 20 nm due to increased mass and reduced electrical mobility.

Proposed method

  • Development of a multiphysics numerical model coupling the ion transport equation with the Navier-Stokes equations (NSE).
  • Simulation of spatiotemporal distributions of electric field, charge density, and fluid flow in a point-to-tube corona configuration.
  • Validation of simulated velocity profiles against experimental measurements at the flow exit.
  • Modeling of particle transport and collection based on electrical mobility and charging dynamics in high-field regions.
  • Use of theoretical models to compare predicted and measured collection efficiencies for 20–150 nm particles.
  • Analysis of particle charging mechanisms, particularly single-charge acquisition, in high-charge-density environments.

Experimental results

Research questions

  • RQ1How does corona voltage affect the velocity and flow rate of EHD flow in a point-to-tube configuration?
  • RQ2Why does particle collection efficiency increase for 10–20 nm particles despite their small size?
  • RQ3What causes the reduction in collection efficiency for particles near 20 nm, and how does this relate to mass and mobility?
  • RQ4How do multiple charges on larger particles (above 20 nm) influence their electrical mobility and collection efficiency?
  • RQ5To what extent do simulated flow and field distributions match experimental velocity profiles?

Key findings

  • EHD flow velocity increases with corona voltage, reaching a maximum of 1–4 m/s at the flow axis.
  • The maximum EHD flow velocity is consistently located along the central axis of the flow channel.
  • For 20–150 nm particles, measured collection efficiency aligns well with theoretical predictions based on electrical mobility.
  • For 10–20 nm particles, collection efficiency increases with decreasing size due to enhanced charging efficiency in high-intensity electric fields.
  • Particles near 20 nm show reduced collection efficiency due to increasing mass and decreasing electrical mobility.
  • Particles larger than 20 nm exhibit increasing collection efficiency as they acquire multiple charges, enhancing their mobility and capture.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.