Skip to main content
QUICK REVIEW

[Paper Review] Asymmetric Similarity Loss Function to Balance Precision and Recall in Highly Unbalanced Deep Medical Image Segmentation

Seyed Raein Hashemi, Seyed Sadegh Mohseni Salehi|arXiv (Cornell University)|Mar 28, 2018
Advanced Neural Network ApplicationsComputer Science39 references12 citations
TL;DR

This paper proposes an asymmetric similarity loss function based on the $F_\beta$ score to balance precision and recall in highly unbalanced 3D medical image segmentation. By combining a patch-wise 3D densely connected network with overlapping patches, B-spline weighted soft voting for fusion, and the asymmetric loss, the method achieves improved F1 and F2 scores and area under the precision-recall curve, reaching 69.8% Dice on MSSEG 2016 and 65.74% on ISBI 2015.

ABSTRACT

Fully convolutional deep neural networks have been asserted to be fast and precise frameworks with great potential in image segmentation. One of the major challenges in utilizing such networks raises when data is unbalanced, which is common in many medical imaging applications such as lesion segmentation where lesion class voxels are often much lower in numbers than non-lesion voxels. A trained network with unbalanced data may make predictions with high precision and low recall, being severely biased towards the non-lesion class which is particularly undesired in medical applications where false negatives are actually more important than false positives. Various methods have been proposed to address this problem including two step training, sample re-weighting, balanced sampling, and similarity loss functions. In this paper we developed a patch-wise 3D densely connected network with an asymmetric loss function, where we used large overlapping image patches for intrinsic and extrinsic data augmentation, a patch selection algorithm, and a patch prediction fusion strategy based on B-spline weighted soft voting to take into account the uncertainty of prediction in patch borders. We applied this method to lesion segmentation based on the MSSEG 2016 and ISBI 2015 challenges, where we achieved average Dice similarity coefficient of 69.8% and 65.74%, respectively, using our proposed patch-wise 3D densely connected network. Significant improvement in $F_1$ and $F_2$ scores and the area under the precision-recall curve was achieved in test using the asymmetric similarity loss layer and our 3D patch prediction fusion method. The asymmetric similarity loss function based on $F_\beta$ scores generalizes the Dice similarity coefficient and can be effectively used with the patch-wise strategy developed here to train fully convolutional deep neural networks for highly unbalanced image segmentation.

Motivation & Objective

  • To address the challenge of highly unbalanced medical image segmentation, where lesion voxels are vastly outnumbered by non-lesion voxels.
  • To reduce bias toward the majority (non-lesion) class in deep learning models, which often leads to low recall and high false negative rates.
  • To improve both precision and recall simultaneously in lesion segmentation tasks, especially prioritizing recall to minimize missed diagnoses.
  • To develop a loss function that generalizes the Dice coefficient and better aligns with clinical priorities through $F_\beta$-based optimization.
  • To integrate patch-based training with uncertainty-aware fusion using B-spline weighted soft voting to enhance boundary prediction reliability.

Proposed method

  • A 3D densely connected fully convolutional network is trained on large, overlapping image patches to improve feature learning and robustness.
  • Image patches are selected using a patch selection algorithm to ensure diversity and coverage of lesion regions.
  • A B-spline weighted soft voting strategy fuses predictions from overlapping patches, reducing uncertainty at patch borders.
  • An asymmetric similarity loss function is introduced, derived from the $F_\beta$ score, to prioritize recall over precision in class-imbalanced settings.
  • The loss function generalizes the Dice coefficient and is optimized end-to-end during training to improve segmentation performance on rare classes.
  • Intrinsic and extrinsic data augmentation is applied to patches to increase training diversity and model generalization.

Experimental results

Research questions

  • RQ1Can an asymmetric loss function based on the $F_\beta$ score effectively balance precision and recall in highly unbalanced 3D medical image segmentation?
  • RQ2How does patch-wise training with overlapping patches and soft voting fusion improve segmentation accuracy, especially at lesion boundaries?
  • RQ3To what extent does the proposed loss function outperform standard Dice loss in terms of F1 and F2 scores and area under the precision-recall curve?
  • RQ4Does the integration of the asymmetric loss with a 3D densely connected network lead to improved performance on benchmark datasets like MSSEG 2016 and ISBI 2015?

Key findings

  • The proposed asymmetric similarity loss function significantly improved the F1 and F2 scores compared to standard Dice-based training.
  • The method achieved a mean Dice similarity coefficient of 69.8% on the MSSEG 2016 challenge dataset.
  • On the ISBI 2015 challenge dataset, the method reached a Dice similarity coefficient of 65.74%.
  • The area under the precision-recall curve was notably enhanced, indicating better performance on the minority (lesion) class.
  • The B-spline weighted soft voting fusion strategy effectively reduced prediction uncertainty at patch borders, improving boundary localization.
  • The combination of patch-wise training, asymmetric loss, and dense connectivity led to state-of-the-art performance on the evaluated benchmarks.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.