Skip to main content
QUICK REVIEW

[Paper Review] Attainability of maximum work and the reversible efficiency from minimally nonlinear irreversible heat engines

M. Ponmurugan|arXiv (Cornell University)|Apr 7, 2016
Advanced Thermodynamics and Statistical MechanicsPhysics and Astronomy1 references7 citations
TL;DR

This paper investigates minimally nonlinear irreversible heat engines operating between a finite-sized hot reservoir and an infinite cold reservoir, using irreversible thermodynamics with Fourier's law for heat transfer. It demonstrates that the reversible (Carnot) efficiency can be attained at finite power under tight coupling (no heat leakage), challenging the conventional view that such efficiency is only possible in the quasi-static, zero-power limit.

ABSTRACT

We use the general formulation of irreversible thermodynamics and study the minimally nonlinear irreversible model of heat engines operating between a time-varying hot heat source of finite size and a cold heat reservoir of infinite size. We find the criterion in which the optimized efficiency obtained by this minimally nonlinear irreversible heat engine can reach the reversible efficiency under the tight coupling condition: a condition of no heat leakage between the system and the reservoirs. We assume the rate of heat transfer from hot to cold heat reservoir obeys Fourier law and discuss physical conditions under which one can obtain the reversible efficiency in a finite time with finite power. We also calculate the efficiency at maximum power from the minimally nonlinear irreversible heat engine under the non-tight coupling condition.

Motivation & Objective

  • To investigate whether the reversible (Carnot) efficiency can be achieved at finite power in nonlinear irreversible heat engines.
  • To analyze the conditions under which maximum work and optimal efficiency are attainable in a minimally nonlinear irreversible thermodynamic model.
  • To explore the role of tight coupling (absence of heat leakage) in enabling finite-power reversible efficiency.
  • To compare the efficiency at maximum power under non-tight coupling with known linear results.
  • To extend the exergy-based optimization framework to nonlinear irreversible systems beyond the linear response regime.

Proposed method

  • Formulates a minimally nonlinear irreversible heat engine model using Onsager's phenomenological relations with a quadratic dissipation term $ r_h J_1^2 $.
  • Applies the exergy concept to compute maximum work extractable from a finite-sized hot reservoir down to the cold reservoir temperature.
  • Imposes the tight coupling condition to eliminate heat leakage between system and reservoirs, enabling theoretical attainment of reversible efficiency.
  • Uses Fourier's law for heat transfer rate $ \dot{Q}_h \propto (1/T_c - 1/T) $, assuming time-dependent hot reservoir temperature $ T(t) $.
  • Derives the optimization condition via calculus of variations on the entropy production rate, leading to a second-order differential equation for $ T(t) $.
  • Solves the resulting Euler-Lagrange equation to determine the optimal temperature trajectory and corresponding efficiency and power output.

Experimental results

Research questions

  • RQ1Can the reversible (Carnot) efficiency be achieved at finite power in a nonlinear irreversible heat engine?
  • RQ2What physical conditions—specifically regarding coupling and heat transfer—enable the attainment of reversible efficiency in finite time?
  • RQ3How does the efficiency at maximum power compare between tight and non-tight coupling conditions in the nonlinear regime?
  • RQ4Is the efficiency at maximum power in the nonlinear model universal or dependent on system parameters, and how does it compare to linear models?
  • RQ5Under what symmetry and functional assumptions does the minimally nonlinear model allow for the theoretical realization of reversible efficiency at finite power?

Key findings

  • The reversible (Carnot) efficiency can be attained at finite power in a minimally nonlinear irreversible heat engine under the tight coupling condition, where no heat leakage occurs between the system and reservoirs.
  • The condition for achieving reversible efficiency is analytically derived and shown to resemble a previously reported criterion in the literature, confirming consistency with nonlinear exergy theory.
  • Under non-tight coupling, the efficiency at maximum power is exactly half the reversible efficiency, and the corresponding work output is half the exergy, matching results from linear irreversible models.
  • The maximum work and optimal efficiency are achieved through a specific time-dependent temperature profile of the hot reservoir, derived from solving the Euler-Lagrange equation of the entropy production functional.
  • The result holds under the assumption of symmetric Onsager coefficients and Fourier’s law for heat transfer, suggesting that nonlinearity alone does not preclude reversible efficiency at finite power.
  • The analysis reveals that the reversible efficiency is not restricted to the zero-power or quasi-static limit in nonlinear systems, challenging long-standing assumptions in irreversible thermodynamics.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.