[Paper Review] Automated Artery Localization and Vessel Wall Segmentation of Magnetic Resonance Vessel Wall Images using Tracklet Refinement and Polar Conversion
This paper proposes a fully automated system for artery localization and vessel wall segmentation in MR vessel wall images using tracklet refinement for centerline detection and polar coordinate transformation to enhance segmentation accuracy. Evaluated on carotid (n=116) and popliteal (n=5) datasets, it achieves a Dice score of 0.824, significantly outperforming traditional methods (0.576) and standard CNNs (0.747).
Quantitative analysis of vessel wall structures by automated vessel wall segmentation provides useful imaging biomarkers in evaluating atherosclerotic lesions and plaque progression time-efficiently. To quantify vessel wall features, drawing lumen and outer wall contours of the artery of interest is required. To alleviate manual labor in contour drawing, some computer-assisted tools exist, but manual preprocessing steps, such as region of interest identification and boundary initialization are needed. In addition, the prior knowledge of the ring shape of vessel wall is not taken into consideration in designing the segmentation method. In this work, trained on manual vessel wall contours, a fully automated artery localization and vessel wall segmentation system is proposed. A tracklet refinement algorithm is used to robustly identify the centerlines of arteries of interest from a neural network localization architecture. Image patches are extracted from the centerlines and segmented in a polar coordinate system to use 3D information and to overcome problems such as contour discontinuity and interference from neighboring vessels. From a carotid artery dataset with 116 subjects (3406 slices) and a popliteal artery dataset with 5 subjects (289 slices), the proposed system is shown to robustly identify the artery of interest and segment the vessel wall. The proposed system demonstrates better performance on the carotid dataset with a Dice similarity coefficient of 0.824, compared with traditional vessel wall segmentation methods, Dice of 0.576, and traditional convolutional neural network approaches, Dice of 0.747. This vessel wall segmentation system will facilitate research on atherosclerosis and assist radiologists in image review.
Motivation & Objective
- To eliminate manual preprocessing steps such as region of interest selection and boundary initialization in vessel wall segmentation.
- To leverage the inherent ring-like structure of vessel walls to improve segmentation robustness and accuracy.
- To develop a fully automated pipeline for artery localization and wall segmentation in 3D MR vessel wall images.
- To enhance segmentation performance by integrating 3D spatial context and overcoming contour discontinuities.
- To support quantitative atherosclerotic plaque analysis and facilitate radiological workflow by reducing manual effort.
Proposed method
- A neural network-based localization architecture identifies candidate artery centerlines in 3D MR vessel wall images.
- Tracklet refinement is applied to connect and refine centerline segments across slices, improving continuity and accuracy.
- Image patches are extracted along the refined centerlines and transformed into a polar coordinate system to preserve 3D vessel wall geometry.
- Polar transformation enables better modeling of the circular vessel wall structure and reduces interference from adjacent vessels.
- A segmentation network processes the polar-transformed patches to delineate lumen and outer wall boundaries.
- The method integrates 3D information through polar representation, enhancing robustness to contour discontinuities and noise.
Experimental results
Research questions
- RQ1Can tracklet refinement improve the accuracy and continuity of artery centerline detection in 3D MR vessel wall images?
- RQ2Does polar coordinate transformation enhance vessel wall segmentation by better modeling the ring-like anatomy?
- RQ3Can a fully automated system outperform traditional and CNN-based segmentation methods without manual initialization?
- RQ4How does the proposed method perform across diverse vessel types, such as carotid and popliteal arteries?
- RQ5To what extent does incorporating prior anatomical knowledge (ring shape) improve segmentation robustness and Dice score?
Key findings
- The proposed system achieved a Dice similarity coefficient of 0.824 on the carotid artery dataset, significantly outperforming traditional methods (0.576).
- It also surpassed standard convolutional neural network approaches, which achieved a Dice score of 0.747 on the same dataset.
- The system demonstrated robust performance on both carotid (3406 slices, 116 subjects) and popliteal (289 slices, 5 subjects) datasets.
- The use of polar coordinate transformation effectively mitigated issues related to contour discontinuity and interference from neighboring vessels.
- Tracklet refinement successfully improved centerline continuity across slices, enabling accurate patch extraction for segmentation.
- The method eliminated the need for manual region of interest selection and boundary initialization, enabling full automation.
Read this paper