Skip to main content
QUICK REVIEW

[Paper Review] Automatic Right Ventricle Segmentation using Multi-Label Fusion in Cardiac MRI

María A. Zuluaga, M. Jorge Cardoso|arXiv (Cornell University)|Apr 5, 2020
Medical Image Segmentation TechniquesComputer Science8 references24 citations
TL;DR

This paper presents a fully automatic, coarse-to-fine multi-atlas segmentation method for the right ventricle (RV) in cardiac MRI using multi-label fusion with a locally normalized cross-correlation (LNCC)-based atlas ranking and iterative STAPLE fusion. The approach achieves high segmentation accuracy in basal slices (Dice = 0.93) but faces challenges in apical slices due to low image quality and small region sizes, with average ejection fraction and ventricular mass errors of 0.15 and 0.37, respectively.

ABSTRACT

Accurate segmentation of the right ventricle (RV) is a crucial step in the assessment of the ventricular structure and function. Yet, due to its complex anatomy and motion segmentation of the RV has not been as largely studied as the left ventricle. This paper presents a fully automatic method for the segmentation of the RV in cardiac magnetic resonance images (MRI). The method uses a coarse-to-fine segmentation strategy in combination with a multi-atlas propagation segmentation framework. Based on a cross correlation metric, our method selects the best atlases for propagation allowing the refinement of the segmentation at each iteration of the propagation. The proposed method was evaluated on 32 cardiac MRI datasets provided by the RV Segmentation Challenge in Cardiac MRI.

Motivation & Objective

  • To address the lack of robust automatic segmentation methods for the right ventricle (RV) in cardiac MRI due to its complex anatomy and motion.
  • To improve segmentation accuracy by leveraging multiple atlases with a dynamic atlas selection strategy based on image similarity.
  • To develop a coarse-to-fine framework that incrementally refines RV segmentation using progressively tighter masks.
  • To evaluate performance on the RV Segmentation Challenge dataset using both image-based and patient-based metrics.
  • To identify limitations in apical slice segmentation and suggest 3D extension as a future direction.

Proposed method

  • A coarse-to-fine segmentation framework is employed, starting with global heart localization using block matching and majority voting on registered atlas labels.
  • In phase II, rigid and non-rigid registration are applied to masked image regions to improve alignment, with only the top 10% best-matching atlases selected using a locally normalized cross-correlation (LNCC) ranking.
  • The selected atlas label images are fused using an enhanced STAPLE algorithm (STEPS), which incorporates consensus-based region-of-interest selection and iterative Markov Random Fields for improved label fusion.
  • In phase III, the rough segmentation is used to initialize affine transformations of all atlas labels, which are then re-fused to refine the segmentation.
  • The method uses intensity-based registration and label fusion, with a focus on 2D slice-by-slice processing due to slice thickness constraints in cardiac MRI.
  • The final segmentation is evaluated using Dice score, Hausdorff distance, and patient-level metrics such as ejection fraction and ventricular mass.

Experimental results

Research questions

  • RQ1Can a multi-atlas propagation framework with dynamic atlas selection improve RV segmentation accuracy in cardiac MRI?
  • RQ2How does a coarse-to-fine strategy with progressive mask refinement affect segmentation performance compared to single-stage fusion?
  • RQ3Why do apical slice segmentations perform worse than basal slice segmentations in intensity-based multi-atlas methods?
  • RQ4To what extent do image quality and small region size in apical slices degrade registration and fusion performance?
  • RQ5Can 3D registration and fusion mitigate the limitations observed in 2D processing of cardiac MRI?

Key findings

  • The method achieved a mean Dice score of 0.93 and Hausdorff distance of 4.31 on basal slices, indicating high segmentation accuracy.
  • Performance degraded on apical slices, with lower Dice and higher Hausdorff distance, primarily due to poor image quality and small region sizes.
  • The regression of endocardial volume at end-diastole (ED) and end-systole (ES) showed high R² values of 0.96 and 0.97, respectively, indicating strong correlation with ground truth.
  • Ejection fraction and ventricular mass estimation errors were low, with mean errors of 0.15 and 0.37, respectively, showing robustness in derived functional metrics.
  • Despite challenges in apical regions, the method produced consistent and reproducible results across the dataset, particularly in basal regions.
  • The study identifies 2D slice-by-slice registration as a key limitation, with 3D processing suggested as a promising future direction to improve apical segmentation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.