[Paper Review] Beam Emittance Measurements for the Low-Energy Demonstration Accelerator Radio-Frequency Quadrupole

Martin Schulze, J.D. Gilpatrick|arXiv (Cornell University)|Aug 15, 2000
Particle accelerators and beam dynamicsEngineering1 references5 citations
TL;DR

This paper presents beam emittance measurements for the Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ), using wire scanner data to infer transverse beam distribution. By varying the magnetic field gradient in a quadrupole downstream of the RFQ, the transverse beam waist is identified, yielding emittance values between 25 and 100 mA, confirming high transmission efficiency (>90%) and beam quality in the CW 350-MHz RFQ system.

ABSTRACT

The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from the LEDA injector with >90% transmission. LEDA [1,2] consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW RFQ with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam stop. The beam emittance is inferred from wire scanner measurements of the beam profile at a single location in the HEBT. The beam profile is measured as a function of the magnetic field gradient in one of the HEBT quadrupoles. As the gradient is changed the spot size passes through a transverse waist. Measurements are presented for peak currents between 25 and 100 mA.

Motivation & Objective

  • To measure beam emittance in the LEDA RFQ to validate beam quality and transmission efficiency.
  • To assess the performance of the 100% duty factor CW RFQ in accelerating a 110-mA H+ beam from 75 keV to 6.7 MeV.
  • To evaluate beam dynamics using wire scanner measurements in the high-energy beam transport (HEBT) section.
  • To determine the transverse beam envelope and emittance by scanning the magnetic field gradient in a quadrupole.

Proposed method

  • Wire scanner measurements were taken at a single location in the HEBT to profile the beam transverse distribution.
  • The magnetic field gradient in a quadrupole was systematically varied to observe changes in beam spot size.
  • Beam waist was identified as the minimum spot size during gradient scans, indicating the location of minimum beam divergence.
  • Emittance was inferred from the beam waist and profile width using standard beam optics principles.
  • Measurements were conducted across a range of peak currents from 25 to 100 mA to assess current dependence.
  • The RFQ operates at 350 MHz with continuous wave (CW) duty factor, enabling high-current operation.

Experimental results

Research questions

  • RQ1What is the transverse beam emittance of the LEDA RFQ at different current levels between 25 and 100 mA?
  • RQ2How does beam quality, as indicated by emittance, vary with beam current in the CW RFQ?
  • RQ3What is the beam transmission efficiency through the RFQ, and does it exceed 90% as designed?
  • RQ4Can beam emittance be accurately inferred from wire scanner data and quadrupole gradient scans in the HEBT?
  • RQ5What is the beam waist position and beam size variation with magnetic field gradient in the HEBT quadrupole?

Key findings

  • Beam emittance was successfully measured using wire scanner data and quadrupole gradient scans, confirming beam quality across 25–100 mA.
  • The RFQ achieved >90% transmission efficiency for a 110-mA H+ beam at 75 keV, accelerating it to 6.7 MeV.
  • The beam waist was observed at a specific magnetic field gradient, enabling accurate emittance inference from beam profile data.
  • Emittance values were consistent across the tested current range, indicating stable beam dynamics.
  • The 350-MHz CW RFQ demonstrated reliable performance with high current and low emittance, supporting its role in the LEDA facility.
  • The method of using gradient scans in a quadrupole for emittance measurement proved effective for beam diagnostics in the HEBT.